DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

A-BControlLogix 32-point DC (10…31.2V) Input Module, Series B

From:A-B | Author:LIAO | Time :2025-08-13 | 765 Browse: | 🔊 Click to read aloud ❚❚ | Share:

ControlLogix 32-point DC (10…31.2V) Input Module, Series B Catalog Number 1756 - IB32, Series B

Topic Page

Important User Information 2

Environment and Enclosure 3

Preventing Electrostatic Discharge 4

Removal and Insertion Under Power 4

European Hazardous Location Approval 5

North American Hazardous Location Approval 6

Before You Begin 7

Module Components 7

Power Requirements 8

Install the Module 8

Key the Module and Removable Terminal Block/Interface Module 9

Wire the Module 11

Wire the Removable Terminal Block (RTB) 12

Assemble the Removable Terminal Block (RTB) and the Housing 13

Install the Removable Terminal Block (RTB) onto the Module 14

Status Indicators 15

Remove the Removable Terminal Block (RTB) from the Module 16

Remove the Module 17

Specifications 18


Important User Information

Solid state equipment has operational characteristics differing from those of electromechanical 

equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls 

(Publication SGI-1.1 available from your local Rockwell Automation sales office or online at 

http://literature.rockwellautomation.com) describes some important differences between solid state 

equipment and hard-wired electromechanical devices. Because of this difference, and also because of 

the wide variety of uses for solid state equipment, all persons responsible for applying this equipment 

must satisfy themselves that each intended application of this equipment is acceptable.

In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages 

resulting from the use or application of this equipment.

The examples and diagrams in this manual are included solely for illustrative purposes. Because of the 

many variables and requirements associated with any particular installation, Rockwell Automation, Inc. 

cannot assume responsibility or liability for actual use based on the examples and diagrams.

No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, 

equipment, or software described in this manual.

Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell 

Automation, Inc., is prohibited.

Throughout this manual, when necessary, we use notes to make you aware of safety considerations

Environment and Enclosure 

This equipment is intended for use in a Pollution Degree 2 industrial 

environment, in overvoltage Category II applications (as defined in IEC 

publication 60664-1), at altitudes up to 2000 m (6562 ft) without derating.

This equipment is considered Group 1, Class A industrial equipment 

according to IEC/CISPR Publication 11. Without appropriate precautions, 

there may be potential difficulties ensuring electromagnetic compatibility in 

other environments due to conducted as well as radiated disturbance.

This equipment is supplied as ‘open type’ equipment. It must be mounted 

within an enclosure that is suitably designed for those specific 

environmental conditions that will be present and appropriately designed to 

prevent personal injury resulting from accessibility to live parts. The interior 

of the enclosure must be accessible only by the use of a tool. Subsequent 

sections of this publication may contain additional information regarding 

specific enclosure type ratings that are required to comply with certain 

product safety certifications.

In addition to this publication, see:

• Industrial Automation Wiring and Grounding Guidelines, for 

additional installation requirements, Allen-Bradley publication 

1770-4.1.

• NEMA Standards publication 250 and IEC publication 60529, as 

applicable, for explanations of the degrees of protection provided by 

different types of enclosure.

Preventing Electrostatic Discharge

Removal and Insertion Under Power

ATTENTION This equipment is sensitive to electrostatic discharge, which can cause 

internal damage and affect normal operation. Follow these guidelines when 

you handle this equipment:

• Touch a grounded object to discharge potential static.

• Wear an approved grounding wriststrap.

• Do not touch connectors or pins on component boards.

• Do not touch circuit components inside the equipment.

• Use a static-safe workstation, if available.

• Store the equipment in appropriate static-safe packaging when not 

in use.

WARNING When you insert or remove the module while backplane power is on, an 

electrical arc can occur. This could cause an explosion in hazardous location 

installations. Be sure that power is removed or the area is nonhazardous 

before proceeding. Repeated electrical arcing causes excessive wear to 

contacts on both the module and its mating connector. Worn contacts may 

create electrical resistance that can affect module operation.

ATTENTION Personnel responsible for the application of safety-related programmable 

electronic systems (PES) shall be aware of the safety requirements in the 

application of the system and shall be trained in using the system

  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 8DIO / 2UAI
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1550 Slice I/O, RS232/485. 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1550 Slice I/O, RS232/485. 8DIO / 2UAI
  • CTI 2500S-23-1550 Slice I/O, RS232/485. 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1050 Slice I/O, Ethernet, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1050 Slice I/O, Ethernet, 8DIO / 2UAI
  • CTI 2500S-23-1050 Slice I/O, Ethernet, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500C-32F-CJC 32-Pin Field Wiring Connector with Cold Junction Compensation
  • CTI 2500C-32F 32-Pin Field Wiring Connector
  • CTI 2500C-8-TC Eight Thermocouple Inputs
  • CTI 2500C-8-RTD Eight RTD Inputs
  • CTI 2500C-8-RL-FC 8 Form-C Relay Outputs
  • CTI 2500C-8-IDO-24V 8 Isolated 24VDC Outputs
  • CTI 2500C-8-IDO-120V 8 Isolated 120VAC Outputs
  • CTI 2500C-16-DO-24V Sixteen 24VDC Digital Outputs
  • CTI 2500C-16-DO-120V Sixteen 120VAC Digital Outputs
  • CTI 500C-16-IDI-24V Sixteen Isolated 24V AC/DC Digital Inputs
  • CTI 2500C-16-IDI-120V Sixteen Isolated 120V AC/DC Digital Inputs
  • CTI 2500C-16-DIDO-SIM Sixteen Digital Input and Output SImulator
  • CTI 2500C-16-DI-24V Sixteen 24V AC/DC Digital Inputs
  • CTI 2500C-16-DI-120V Sixteen 120V AC/DC Digital Inputs
  • CTI 2500C-RBC-RS485 RS485 Remote Base Controller
  • CTI 2500C-RBC-PRF Profibus Remote Base Controller
  • CTI 2500C-PS-24V-35 35-Watt DC Power Supply
  • CTI 2500C-PS-120V-35 35-Watt AC Power Supply
  • CTI 2500C-R8 Eight-Slot Base
  • CTI 2500C-R4 Four-Slot Base
  • CTI 2500C-R16 Sixteen-Slot Base
  • CTI 2500C-2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2500C-J750 Compact Janus PAC with 3MB Project Memory
  • CTI 2500C-C300 CPU with 512K User Memory
  • CTI 2500C-C200 CPU with 256K User Memory
  • CTI 2500C-C100 CPU with 128K User Memory
  • CTI 2500C-8-AO 8 Analog Outputs
  • CTI 2500C-8-AI 8 Analog Inputs
  • CTI 2559-FCAL Precision Calibration Connector
  • CTI 2559-FPC 40-Position Screw-Terminal Connector
  • CTI 2500-RFC PLC to RF Modem Cable
  • CTI 2500-40F 40-Position Standard Screw-Terminal Connector
  • CTI 2505 Vibration Sensor Interface Module
  • CTI 2554-A 4-Channel Isolated High Speed Counter Module
  • CTI 2553-A 2-Channel Mag Meter Input Module
  • CTI 2502 2-Channel High Speed Counter Input Module
  • CTI 2559-TC 8-Channel Thermocouple Input Module
  • CTI 2556-A 16-Channel Isolated Thermocouple Input Module
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2551-A 8-Channel Isolated Thermocouple Input Module
  • CTI 2559-RTD 8-Channel RTD Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2557 16-Channel RTD Input Module
  • CTI 2552-A 8-Channel Isolated RTD Input Module
  • CTI 2534 8-Point Form-C Relay Output Module
  • CTI 2532 16-Point Form-A Relay Output Module
  • CTI  2531 32-Point Form-A Relay Output Module
  • CTI  2530 8-Point Form-C Relay Output Module
  • CTI  2562 8-Channel Analog Output Module
  • CTI  2560-A 8-Channel Isolated Analog Output Module
  • CTI  2501 8in/4out Analog Module
  • CTI  2558 8-Channel Analog Input Module
  • CTI  2555-A 16-Channel Analog Input Module
  • CTI  2550-A 8-Channel Isolated Analog Input Module
  • CTI  2599 8/16/32-Point AC Output Module
  • CTI  2598-8 8-Point AC Output Module
  • CTI   2598 8/16-Point AC Output Module
  • CTI   2597 8/16/32-Point DC Output Module
  • CTI 2596-8 8-Point DC Output Module
  • CTI 2596 8/16-Point DC Output Module
  • CTI 2595 16-Point TTL/Word Output Module
  • CTI 2591-EF 16-Point Isolated 11-146 VDC Output with Front Panel Accessible Fuses
  • CTI 2591-A 16-Point Isolated 11-146 VDC Output Module
  • CTI 2590-EF 16-Point Isolated 20-132 VAC Output with Front Panel Accessible Fuses
  • CTI 2590-A 16-Point Isolated Discrete 20-132 VAC Output Module
  • CTI 2589-B 8/16/32-Point Universal Discrete Input Module
  • CTI 2589-A 8/16/32-Point Universal Discrete Input Module
  • CTI 2588-8 8-Point Universal Discrete Input Module
  • CTI 2585 16-Point TTL/Word Input Module
  • CTI 2582 16-Point Isolated 125 VDC Input Module
  • CTI 2581 16-Point Isolated 12-56 VDC Input Module
  • CTI 2580 16-Point Isolated 95-132 VAC Input Module
  • CTI 2500-TAP RS485 Network Tap
  • CTI 2500-RIO-B RS485 Remote Base Controller
  • CTI 2500-RIO-A RS485 Remote Base Controller
  • CTI 2500-RBC Profibus Remote Base Controller
  • CTI 2515-A 100-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2515 100-Watt AC Power Supply (MATURE - replaced by 2515-A)
  • CTI 2513-A 75-Watt DC Power Supply with Redundancy Support
  • CTI 2513 75-Watt 24VDC Power Supply
  • CTI 2512-A 75-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2512 75-Watt AC/DC Power Supply
  • CTI 2510 125 VDC Power Supply
  • CTI 2500-SSB Single Slot Blank Front Panel
  • CTI 2500-R11-A Eleven-Slot Redundant Base
  • CTI 2500P-R16 Sixteen-Slot Base with High-Speed Channel
  • CTI 2500P-R8 Eight-Slot Base with High-Speed Channel
  • CTI 2500P-R4 Four-Slot Base with High-Speed Channel
  • CTI 2541 Redundant Processor Manager Module
  • CTI 2577 Profibus DP Slave Adapter
  • CTI 2573-MOD Serial Interface Adapter with MODBUS
  • CTI 2572-AF Fast Ethernet TCP/IP Adapter with Optical Fiber Connection
  • CTI 2572-A Fast Ethernet TCP/IP Adapter
  • CTI 2572 Ethernet TCP/IP Adapter
  • CTI 2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2576 DeviceNet™ Scanner Module (MATURE)
  • CTI 2500P-ECC1 Ethernet Communications Coprocessor
  • CTI 2500P-JACP Janus Application Coprocessor
  • CTI 2500P-ACP1 Application Coprocessor (MATURE - replaced by 2500P-JACP)
  • CTI 2500P-J450 Janus PAC with 2MB Project Memory
  • CTI 2500-C400 CPU with 3072K User Memory
  • CTI 2500-C300 CPU with 512K User Memory
  • CTI 2500-C200 CPU with 256K User Memory
  • CTI 2500-C100 CPU with 128K User Memory
  • CTI 2500P-J750 Janus PAC with 3MB Project Memory
  • Shinkawa WHF3006M Displacement Converter
  • Shinkawa JBP-220 (P-24-94A / P-24-94B) Circuit Board Module
  • SHINKAWA   WKN-142K5  2-WIRE VIBRATION TRANSDUCER
  • Shinkawa FRP-321 (P-26-54A / P-26-54B) Circuit Board Module
  • Shinkawa IOP-160 (P-25-72A / P-25-72B) Circuit Board Module
  • Shinkawa PK-147B-1 / PK-147A-1 Circuit Board Module
  • Shinkawa CPP-91A Circuit Board Module
  • Shinkawa FRP-177 PCB Module
  • Shinkawa CPP-127 (P-26-74A / P-26-74B) Circuit Board Module
  • Shinkawa FRP-227 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa MDP-104 (P-25-83A / P-25-83B) Circuit Board Controller
  • Shinkawa VK-143P2 High-precision eddy current sensor driver/signal conditioner
  • Shinkawa FRP-226 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa CPP-107A P-22-99A P-22-99B Circuit Board Module