# Introduction to HIMA F8652 98465266 PLC Module
You may be referring to the HIMA F8652 series PLC modules. Below is an introduction covering the features, technical parameters, applications, and other aspects of different models:
## Product Features
### High Safety
- **Redundant Design**: Adopts a redundant hardware architecture. Critical components such as power modules and processors are usually backed up to ensure the system operates normally even if a component fails.
- **Strict Development Process**: Follows rigorous software development processes, undergoes extensive testing and verification, and complies with relevant safety standards such as IEC 61508. It can meet safety requirements up to SIL 3 or even SIL 4, making it suitable for various hazard protection applications.
### High Performance
- **Multi-Core Processor Architecture**: Based on multi-core processors, it can quickly process large volumes of input/output signals and complex control logic. It meets the real-time requirements of complex safety applications and responds rapidly to safety events such as emergency shutdowns, fire alarms, and gas leakage alarms.
- **High-Speed Data Processing**: Equipped with high-speed data processing capabilities, it can complete data collection, analysis, and processing in a short time, ensuring the system's rapid response and stable operation.
### Ease of Use
- **Intuitive Programming Interface**: Provides an intuitive programming interface supporting languages such as F Programming Language, Structured Text, and Ladder Logic, facilitating user development and maintenance. Even non-professionals can easily get started.
- **Rich Function Library**: Features a rich function library containing various commonly used control algorithms and functional modules. Users can directly call them, reducing programming workload and difficulty.
### Flexible Scalability
- **Expandable I/O Modules**: Can be expanded with multiple I/O modules. For example, the F8652X can support up to 64 I/O modules, meeting I/O point requirements in different scenarios, with a maximum capacity of 4,096 I/O points.
- **Multiple Communication Interfaces**: Equipped with various communication interfaces such as Ethernet, PROFIBUS, CAN, RS-232, and RS-485, enabling high-speed and stable data communication and integration with other devices or systems, facilitating the construction of complex distributed control systems.
## Main Models and Parameters
### F8652X
- **Processor**: Multi-core processor
- **Memory**: 1GB RAM, 8GB storage space
- **Communication Interfaces**: Ethernet, PROFIBUS, CAN, etc.
- **Safety Level**: SIL 4
- **Operating Temperature**: -40°C to 85°C
- **Dimensions**: 144mm x 144mm x 64mm
- **Installation Method**: DIN rail mounting
### F8652E
- **Processor**: NXP MPC8572E, 1GHz主频
- **Memory**: 512MB DDR2, 2GB Flash
- **Expansion Interfaces**: PCIe, Ethernet
- **Communication Interfaces**: RS-232, RS-485
- **Power Supply Voltage**: 24V DC
- **Power Consumption**: <50W
- **Ambient Temperature**: -40°C to +85°C
- **Protection Rating**: IP67
- **Dimensions**: 233mm x 175mm x 30mm
- **Weight**: 0.8 kg
## Application Fields
- **Oil and Gas Industry**: Used to control safety in processes such as oil and gas production, storage, and transportation, e.g., preventing blowouts, fire explosions, and leaks.
- **Chemical Industry**: Applied to control safety in chemical production processes, such as preventing explosions, poisoning, and fires.
- **Power Industry**: Utilized to ensure safety in power generation, transmission, and distribution, e.g., preventing short circuits, overloads, and accidents.
- **Nuclear Industry**: Employed to control safety in nuclear power plants, such as preventing nuclear leaks and accidents to protect personnel and the environment.
- **Railway Transportation**: Used to ensure railway traffic safety, such as preventing train collisions and derailments, and safeguarding train operation.
- **Manufacturing**: Applied to production line control, equipment monitoring, and process control to ensure the safety and stability of production processes.
HIMA F8652 is a central module commonly used in safety control systems. The following is an introduction to its usage precautions and parameters: ### Usage Precautions - **Module Installation and Removal**: When installing, the module should be placed on the terminal block and pressed firmly inward to avoid triggering error signals in the system. Before removal, the fixing screws must be fully loosened. The module can be quickly taken out upward by pressing the eject lever (located at the front label), and attention should also be paid to preventing the triggering of error signals. - **Parameter Setting**: It is necessary to check whether the bus station number and transmission rate settings at switch S1 are correct. For the serial interface, the bus station number can only be set to 1-31; in an Ethernet network, the bus station number can be set to 1-99. Switches S1-6/7 and S1-1/2/3/4/5 need to be set correctly. - **Battery-related Matters**: The buffer battery can last for 200 days at 60°C when there is no voltage supply. It is recommended to replace the buffer battery at the latest 6 years after the module is in operation, or within three months when "bati" is displayed. - **Daily Maintenance**: Pay attention to checking the LED indicators on the power modules F7126, F7130A, and other modules. If the LED is off, check the 24V DC power supply. Only replace faulty modules; otherwise, it may cause the PLC to shut down. ### Module Parameters - **Electrical Parameters**: Input voltage is 24V DC, output voltage is 0-10V DC, and maximum output current is 500mA. - **Performance Parameters**: It usually adopts a dual-core ARM Cortex-A9 or TDA4VM processor, with 1GB RAM and 4GB Flash memory. It can be expanded to up to 32 input/output modules and supports communication protocols such as Modbus, Profinet, and EtherNet/IP. - **Safety Parameters**: Complies with IEC 61508 SIL 3 and IEC 62368-1/VDE V 3.0 safety standards, featuring high security. - **Environmental Parameters**: Operating temperature range is -20°C to 60°C, and the protection rating is IP20. - **Physical Parameters**: The size is approximately 120mm x 80mm x 40mm (slight variations may exist among different models), and it is lightweight, facilitating installation and use.