The main function is differential protection: to protect against differential currents in power systems such as generators and substations. High-precision measurement: Provide high-precision measurement to ensure the accuracy of data collection. Real-time data collection: It can collect and transmit data in real time, supporting real-time monitoring and analysis. Multiple communication interfaces: Equipped with multiple communication interfaces, it facilitates data exchange with other devices and control systems. Automatic calibration: It features an automatic calibration function to ensure the stability and accuracy of the measurement. Multi-point measurement: Supports simultaneous monitoring of data from multiple points at different locations or in pipelines. Data recording and storage: It is equipped with data recording and storage functions, facilitating subsequent analysis and review. Product features: High reliability: Provides stable protection performance under various operating conditions. High sensitivity: It can quickly detect fault currents in the system and take protective measures in a timely manner. Fast response speed: It can protect the system in a short time and prevent faults from expanding. Good stability: It maintains stable performance during long-term operation, ensuring the safe operation of the power system. Digital technology design: By adopting digital technology, measurement accuracy and stability are enhanced, adapting to complex power systems. The price information varies among different suppliers. For instance, some suppliers quote 999 yuan per piece, while others quote 52 yuan per unit. If you need to make a purchase, it is recommended that you contact multiple suppliers for inquiries, understand the prices and services of different suppliers, so as to make the best choice. Pay attention to verifying the specific model and configuration of the product to ensure that they meet the actual needs. In conclusion, the ABB SPAD346C3-AA is a powerful and stable microcomputer protection device, suitable for protection and control scenarios in various power systems.
ABB SPAD 346 C3-AA is a multi-functional protection relay, mainly used to protect two-winding power transformers and generator transformer units and other equipment. The following is an introduction to its usage method: Function configuration Differential protection: Through the differential relay module, set appropriate differential current threshold values, ratio braking characteristics and other parameters to protect the equipment from winding short circuits and inter-turn faults. Ground fault protection: According to the grounding method of the system, select the protection principle of the ground fault relay module, such as the stable differential current principle, high impedance principle, etc., and set the corresponding action current and time. Overcurrent protection: By using an overcurrent relay module, parameters such as the operating current and operating time of three-phase overcurrent are configured to provide backup protection for the equipment. Parameter setting: Rated current setting: According to the rated current of the protected equipment, set the rated current value of the relay. Generally, there are two options: 1A and 5A. CT ratio setting: According to the actual ratio of the current transformer used, the corresponding CT ratio setting is carried out in the relay to ensure the accuracy of measurement and protection. Protection setting: According to the protection requirements of the equipment, set the action setting values of various protection functions, such as differential current threshold value, ground fault action current, overcurrent action current, etc. Wiring and connection of current input wiring: Correctly connect the current circuits of each phase and the ground fault current circuit of the equipment to the corresponding current input terminals of the relay. Output wiring: According to the requirements of the protection action, connect the output contacts of the relay to the tripping circuit of the circuit breaker, signal circuit, etc. Power supply and communication wiring: Provide a stable power supply for the relay and connect communication interfaces as needed to achieve data exchange with the monitoring system. Pre-power-on inspection for debugging and testing: Check whether all wiring is correct and secure, and confirm that the power supply polarity and voltage level meet the requirements. Preliminary power-on test: After power-on, observe whether the indicator lights, display screens, etc. of the relay are normal, and check the working status of each module. Protection function test: By simulating various fault conditions, such as differential current fault, ground fault, overcurrent fault, etc., test whether the protection action of the relay is correct and reliable. Communication function test: If the communication function is configured, it is necessary to test whether the communication with the monitoring system is normal and whether the data transmission is accurate. Regular inspection for operation and maintenance: Regularly check the working status of the relay to see if there are any abnormal alarms or fault information. Data recording and analysis: By leveraging the data recording function of relays, regularly analyze the operational data and fault information of the equipment to promptly identify potential issues. Software upgrade and maintenance: According to the software upgrade package provided by the manufacturer, upgrade the software of the relay in a timely manner to obtain better functions and performance. When using ABB SPAD 346 C3-AA, relevant safety operation procedures and operation guidelines should be strictly followed to ensure the safety of personnel and equipment. Meanwhile, for specific parameter Settings and debugging operations, it is recommended to refer to the user manual of the equipment or consult professional technicians for operation.
ABB SPAD346C3-AA is an integrated differential relay, mainly used to protect double-winding transformers and generator-transformer devices from winding short circuits, inter-turn faults, ground faults and short circuits, and can also protect generators from winding short circuits and short circuits. The following are some key parameters and features of ABB SPAD346C3-AA: Technical Parameters Brand: ABB Model: SPAD346C3-AA Product Features Integrated Protection: including three-phase differential relay, overcurrent relay and ground fault relay. Differential protection: It adopts the principles of stable differential current, high impedance, calculation or measurement of residual current, and neutral point current to provide protection against winding short circuits and inter-turn faults. Overcurrent protection: It provides three-level overcurrent protection and two-level ground fault backup protection. Operating characteristics: Short operating time, and stable operation even when the current transformer is partially saturated. Harmonic locking: Locking is carried out based on the ratio of the second harmonic to the fundamental component of the differential current to prevent false operation when there is a surge current in the transformer. Locking is carried out based on the ratio of the five-wave and fundamental components of the differential current to prevent false operation when the transformer is over-excited. Digital vector group matching: Double-winding transformer protection does not require transformers, and the digital vector groups on the high-voltage side and low-voltage side are matched. Output and input: Four trip and four signal relay outputs, five programmable external control inputs. Rated current: The rated currents of the relay are 1A and 5A respectively.
User name | Member Level | Quantity | Specification | Purchase Date |
---|