R 1/2 Process Connection (1/2 NPT to R 1/2 Adapter) ...................................R
Five Year Warranty ....................................................W
Supplemental Customer Tag (Stainless Steel Tag wired onto Transmitter) .........................T
Model Codes IGP20 1
Gauge, Abs. and d/p Pressure IGP10 - IGP20 - IAP10
09/1999 CA 2A-1C13 B-(en)
1-3
Intelligent Bracket-Mounted Gauge Pressure Transmitter IGP20
Electronics Versions and Output Signal
Digital, FOXCOM, or 4 to 20 mA dc, Software Selectable .............D
Digital, HART/4 to 20 mA .............................T
4 to 20 mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Structure Code - Process Cover, Sensor Material, and Sensor Fill Fluid
Hi-Side Cover . Sensor Material. . Fill Fluid
Steel ...... Co-Ni-Cr...... Silicone . . . . . . . . . . . . . . . . . . . . . 10
Steel ...... Co-Ni-Cr...... Fluorinert . . . . . . . . . . . . . . . . . . . . . 11
Steel ...... 316L ss ...... Silicone. . . . . . . . . . . . . . . . . . . . . . 12
Steel ...... 316L ss ...... Fluorinert . . . . . . . . . . . . . . . . . . . . . 13
Steel ...... Hastelloy C .... Silicone. . . . . . . . . . . . . . . . . . . . . . 16
Steel ...... Hastelloy C .... Fluorinert . . . . . . . . . . . . . . . . . . . . . 17
316 ss . . . . . Co-Ni-Cr...... Silicone ...... Value Package . . . . . . . 20
316 ss . . . . . Co-Ni-Cr...... Fluorinert . . . . . . . . . . . . . . . . . . . . . 21
316 ss . . . . . 316L ss ...... Silicone. . . . . . . . . . . . . . . . . . . . . . 22
316 ss . . . . . 316L ss ...... Fluorinert . . . . . . . . . . . . . . . . . . . . . 23
316 ss . . . . . Hastelloy C .... Silicone. . . . . . . . . . . . . . . . . . . . . . 26
316 ss . . . . . Hastelloy C .... Fluorinert . . . . . . . . . . . . . . . . . . . . . 27
Hastelloy C. . . Hastelloy C .... Silicone. . . . . . . . . . . . . . . . . . . . . . 46
Hastelloy C. . . Hastelloy C .... Fluorinert . . . . . . . . . . . . . . . . . . . . . 47
Span Limits (Differential Pressure Units)
kPa . . . . . . psi . . . . . . . . mbar . . . . . . . inH2O.... mmHg
0.87 and 50 . . 0.125 and 7 . . . . 8.7 and 500 . . . . 3.5 and 200 . . 6.5 and 375 . . . . B
MPa . . . . . psi . . . . . . . . bar or kg/cm² . . inH2O.... mmHg
0.007 and 0.21 1 and 30 ..... 0.07 and 2.1 . . . 28 and 840 . . 52 and 1550 ....C
0.07 and 2.1 . . 10 and 300 . . . . 0.7 and 21 . . . . . . . . . . . . . . . . . . . . . . . . D
0.7 and 21 . . . 100 and 3000 . . . 7 and 210 ........................E
Process Connector Type (Material Same as Process Cover Material)
None, Cover tapped for 1/4 NPT ....................................0
1/4 NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1/2 NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rc 1/4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Rc 1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1/2 Schedule 80 Welding Neck.....................................6
Conduit Connection
1/2 NPT Conduit Connection, Both Sides ...................................1
PG 13.5 Conduit Connection, Both Sides (available only with Electrical Safety Codes E & N) .........2
Electrical Safety (See Electrical Safety Specifications Section for Description)
CENELEC Certified Intrinsically Safe, ia .......................................E
CENELEC Certified Flameproof, d..........................................D
CSA Certified, ia, d, and n ..............................................C
EUROPEAN Ex, N, IIC. Nonsparking ........................................N
FM Approved, ia, d, and n ..............................................F
SAA Certified, EEx, d, IIC ..............................................A
Options
Mounting Bracket Set
Painted Steel Bracket with Plated Steel Bolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M1
Stainless Steel Bracket with Stainless Steel Bolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M2
Indicator with Internal Pushbuttons (Standard equipment on Electr. Version I)
Digital Indicator, Pushbuttons, and Window Cover, for Electr. VersionD&T only. . . . . . . . . . . . . . . . . . . . . . L1
DIN 19213 Construction, used with Process Connector Code 0 and 316 ss Covers Only(b)
Single Ended Process Cover with M10, B7 Steel Bolting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D1
Double Ended Process Cover with M10, B7 Steel Bolting (Blind Kidney Flange on Back)(c)(d). . . . . . . . . . . . . . . D2
Single Ended Process Cover with 7/16 in, B7 Steel Bolting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D3
Double Ended Process Cover with 7/16 in, B7 Steel Bolting (Blind Kidney Flange on Back)(c)(d). . . . . . . . . . . . . . D4
Cleaning and Preparation
Unit Degreased - (Not for Oxygen/Chlorine) (Available only with Structu-re Codes having Silicone). . . . . . . . . . . . . X1
Cleaned and Prepared for Oxygen Service (Available only withStructure Codes having Flourinert