The service personnel, when operating directly on the powered unit, must be electrostatically
discharged.
All safety related regulations must be observed.
Installation Environment
The equipment is not intended for continuous exposure to direct sunlight. This might accelerate the
aging process of the front panel film.
The equipment is not intended for installation in contact with corrosive chemical compounds. Check
the resistance of the front panel film to a specific compound before installation.
3.7 Cleaning Faceplates
The equipment must be cleaned only with a soft cloth and neutral soap product. Do not use solvents.
3.8 Getting Started
ePALMs must be programmed with the Designer software.
To program an ePALM you will have to connect it to a personal computer running the Designer
software; the ePALM must be in Configuration mode to be programmed.
3.8.1 Serial Communication
Make sure that Designer is correctly configured to communicate with the communication port to
which the cable attached.
The serial communication parameters between the panel and the personal computer are:
speed: 9600/38400 baud
parity: None
stop bit: 1
The Designer software defaults to the correct parameters.
3.8.2 Ethernet Communication
When applicable, Designer can use Ethernet to connect to the panel. Make sure all network
parameters are properly set to ensure communication between Designer and the panel.
The version of Designer software must be compatible with the firmware version of the panel to be
programmed. Call technical support for more information on compatibility between firmware and
programming software.
3.9 Troubleshooting
In the case it might be impossible to switch the handheld to Configuration Mode due to problems in
the start-up phase, follow the procedure described below:
1. Switch off the unit
2. Press and hold any 3 keys
3. Turn on the unit and hold the keys pressed until Configuration Mode will be shown on the screen.
Connections
The ePALM10 is available in several versions, featuring different communication cables and different
solutions for the enabling switches.
4.1 Serial Communication - Types –0061 and –0062
ePALM types –0061 and -0062 include all standard UniOP connections and are suitable for all
common serial communication links.
The ePALM10-0061 includes a communication cable with a length of 5 meters.
The ePALM10-0062 includes a communication cable with a length of 10 meters.
The cable does not have a connector at its loose end as it is intended to be wired directly in the control
cabinet.
The following groups of signals are available in the cable:
PC/Printer Port
PLC Port
Aux Port
Power
Emergency Stop button – two NC contacts
Two 2-positions enabling switches – NO contacts
In all the most common configurations, the signals are wired to the cable and there will be no need to
open the unit to access the terminal blocks.
Note: the ePALM10 unit does not include a current loop (20 mA) interface in the PLC port. The
communication modules TCM04 (Interbus), TCM07 (Simatic S7 MPI without optical
insulation), TCM08/TCM18 (Profibus DP) and TCM10/SCM11 (Ethernet) are not supported.
Internally to the product all signals, excluding emergency stop, are wired to a detachable interface
board with five terminal blocks.
The position of the terminal blocks and the numbering of the contacts are shown in the figure belo