DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

ABBMNS® Digital ABB Ability™ Condition Monitoring for electrical systems - CMES User Management – Quick guide ABB Ability™ Condition Monitoring for

From:ABB | Author:LIAO | Time :2025-08-08 | 281 Browse: | 🔊 Click to read aloud ❚❚ | Share:
  1. General 1.1. Target Group The MNS Digital Edge device is the hardware platform for ABB Ability™ Condition Monitoring for electrical systems (in the following ‘CMES’). Audiences of this manual are service technicians and switchgear operators on site. This document describes the communication and user interfaces of the MNS Digital Edge device and CMES. The reader shall be familiar with the terms and concept of ABB MNS Low Voltage Switchgear. The reader shall be familiar with the terms and concept of Microsoft Windows®.

    1.2. Terminology List of the terms, acronyms, abbreviations and definitions that the document uses. Abbreviation Term Description CMES Abbreviation for on-premise ABB Ability™ Condition Monitoring for electrical systems MNS Digital Edge Hardware platform for on-premise Edge computing, including CMES and cloud connectivity MNS Modular Low Voltage Switchgear family from ABB Windows OS Windows Operating System. Windows® is a registered trademark of Microsoft Corporation. All other trademarks are the property of their respective owners. 1.3. Related Documentation [1] 1TGC908002M0203 ABB Ability Condition Monitoring for electrical systems – CMES - User Manual 1.4. Related System Version The content of this document is related to MNS Digital Release 2.0 INTRODUCTION 2 1TGC908006M0202 2. Introduction This document provides an introduction on how to setup or change login credentials for the user management of the CMES. 2.1. Default settings The MNS Digital Edge is provided from ABB with the custom specific project installed. Within project specification the customer defines the number of users which have access to CMES and the respective user roles. In this case ABB will set-up the CMES with the agreed user accounts. After delivery it’s mandatory to change at least the user passwords. In case the users and roles are not defined from project, 2 default users are installed: Administrator and Operator. This is also valid when the MNS Digital Edge is ordered as spare part. Default login credentials are: Administrator User name: EdgeGwAdmin Password: PleaseChangeMe Operator User name: EdgeGwUser Password: PleaseChangeMe For cyber security reason, it’s mandatory to change the password after installation of the MNS Digital Edge. ABB will take no liability caused by using the default passwords. Please contact your IT department about details of password management and cyber security measures in your company. A process for regular update of anti-virus software needs to be implemented. By default, the Windows Defender is installed and activated. Please ensure to update the Windows OS and the anti-virus software on regular basis.


  2. 1.2. Terminology List of the terms, acronyms, abbreviations and definitions that the document uses. Abbreviation Term Description CMES Abbreviation for on-premise ABB Ability™ Condition Monitoring for electrical systems MNS Digital Edge Hardware platform for on-premise Edge computing, including CMES and cloud connectivity MNS Modular Low Voltage Switchgear family from ABB Windows OS Windows Operating System. Windows® is a registered trademark of Microsoft Corporation. All other trademarks are the property of their respective owners. 1.3. Related Documentation [1] 1TGC908002M0203 ABB Ability Condition Monitoring for electrical systems – CMES - User Manual 1.4. Related System Version The content of this document is related to MNS Digital Release 2.0 INTRODUCTION 2 1TGC908006M0202 2. Introduction This document provides an introduction on how to setup or change login credentials for the user management of the CMES. 2.1. Default settings The MNS Digital Edge is provided from ABB with the custom specific project installed. Within project specification the customer defines the number of users which have access to CMES and the respective user roles. In this case ABB will set-up the CMES with the agreed user accounts. After delivery it’s mandatory to change at least the user passwords. In case the users and roles are not defined from project, 2 default users are installed: Administrator and Operator. This is also valid when the MNS Digital Edge is ordered as spare part. Default login credentials are: Administrator User name: EdgeGwAdmin Password: PleaseChangeMe Operator User name: EdgeGwUser Password: PleaseChangeMe For cyber security reason, it’s mandatory to change the password after installation of the MNS Digital Edge. ABB will take no liability caused by using the default passwords. Please contact your IT department about details of password management and cyber security measures in your company. A process for regular update of anti-virus software needs to be implemented. By default, the Windows Defender is installed and activated. Please ensure to update the Windows OS and the anti-virus software on regular basis.

  3. Password Complexity Rules and Password History The password has to contain characters from three of the following categories: • Uppercase letters of European languages (A through Z, with diacritic marks, Greek and Cyrillic characters) • Lowercase letters of European languages (a through z, sharp-s, with diacritic marks, Greek and Cyrillic characters) • Base 10 digits (0 through 9) • Non-alphanumeric characters (special characters): (~!@#$%^&*_-+=`|(){}[]:;"'<>,.?/) Currency symbols such as the Euro or British Pound are not counted as special characters for this policy setting. • Any Unicode character that is categorized as an alphabetic character but is not uppercase or lowercase. This includes Unicode characters from Asian languages A new password is only accepted by Windows when it is differs from four previous passwords.

  4. Since the MNS Digital Edge is connected to an Ethernet network it is customer’s sole responsibility to provide and continuously ensure a secure connection between the MNS Digital Edge and customer network or any other network (as the case may be). The MNS Digital Edge has following service ports open on the integrated Ethernet interfaces: Port Service Purpose 443 https / wss WEB user-interface of ABB Ability™ Condition Monitoring for electrical systems - CMES 3389 RDP Windows remote login, e.g. used for the above described user password management Customer shall establish and maintain appropriate measures (such as but not limited to the installation of firewalls, application of authentication measures, encryption of data, installation of antivirus programs, etc.) to protect the MNS Digital Edge including CMES, the network, its system and interfaces against any kind of security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB Ltd. and its affiliates are not liable for damages and/or losses related to such security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information.

  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO HSL-4XMO-TB-D103 HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • AADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink  PICMG Single Board Computers  NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 industrial control motherboard
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC
  • ADLINK/AMPRO CM-435-v2/CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Technology 51-37111-0C1 PCB Interface Card