packing/unpacking functions, and many supporting functions.
There is also a data freeze detection function that can be used to
help detect if a data value has stopped being updated.
• Alarm reset : CPUM front-panel button used to manually clear the alarms (and
relays) latched by MPC4/IOC4T and AMC8/IOC8T card pairs in the
rack
• VM600 MPS rack (CPUM) security : Used to limit the functionality of a machinery protection system
(MPS) that is available via the system Ethernet connections of a
CPUM/IOCN card pair, helping to reduce the possibility of
interference in the machinery protection function of the rack itself
and/or in the machinery being monitored
• Event logging : VM600 system event and measurement event logging with up to
10000 of the most recent events stored on the CPUM (in nonvolatile memory).
Note: System event logs and measurement event logs are
downloaded from a CPUM using the VM600 MPSx software.
• Status indication : CPUM front-panel LEDs (front of VM600 rack) indicate the mode of
operation and status of the CPUM card
Communications interface
• VM600 rack (system)
communications
: Uses a VME communications link for communications with
MPC4/IOC4T and AMC8/IOC8T card pairs (via the VME bus on the
VM600 rack’s backplane).
Uses a system Ethernet connection for communications with a
computer running software such as VM600 MPSx.
• Fieldbus communications
(data gateway)
: Acts as a fieldbus server (slave) device that obtains data from
cards in the VM600 rack (that is, from MPC4/IOC4T and
AMC8/IOC8T card pairs) to share with fieldbus client (master)
devices such as a DCS or PLC:
• The CPUM can act as a Modbus server and use the fieldbus
interfaces to share data via Modbus RTU and/or Modbus TCP.
Note: The configuration of the fieldbus interfaces and the definition
of the data to be shared via fieldbus is defined by a Modbus
configuration file that is uploaded to the CPUM card using the
CPUM Configurator software.
Fieldbus interfaces
Number of channels : Multiple fieldbus interfaces (ports).
Ethernet and/or serial: Modbus and/or PROFINET.
Data transfer
• Modbus : Up to 131072 registers/words and 131072 coils/bits total.
That is, up to 2 × 65536 registers/words and 2 × 65536 coils/bits
(holding and discrete).
• PROFINET : Maximum slot size of 128 bytes.
Note: PROFINET is supported by later versions of the CPUM card
running firmware version 081 or later.
It was originally only supported by earlier versions of the CPUM card
running a special PROFINET version of firmware (version 801) that is
no longer supported.
Contact your local Meggitt representative or Meggitt SA for further
information.
CPU module (CPUM PC/104 slot 1)
Note: The CPU module is fitted to all versions of the CPUM card.
Module type : PFM-541I or equivalent
Processor type : AMD Geode™ LX800
Processor Speed : 500 MHz
Memory : 256 MB DRAM
Power supply to module (input) : 5 VDC, <1.8 A
Operating system : QNX
Communication interfaces – serial
Number : 2
Primary serial interface
• Network interface : RS-232
• Data transfer rate : Up to 115.2 kBaud
• Network topologies : Point-to-point
• Protocols : Meggitt TCP/IP proprietary protocol for communication with the
VM600 MPSx software
• Function : VM600 rack configuration and communications using the
VM600 MPSx software
• Connector : RS232 on CPUM card (see Connectors on page 10)
Secondary serial interface (requires IOCN card)
• Network interface : RS-232 or RS-485 (half-duplex (2-wire) or full-duplex (4-wire))
• Data transfer rate : Up to 115.2 kBaud
• Distance between devices : According to the relevant standard
• Network topologies : Point-to-point for RS-232 links.
Point-to-point or linear (daisy-chained) for RS-485 networks.
• Protocols : Modbus RTU
• Function : Fieldbus Modbus RTU communications
• Connector : RS on IOCN card (see Connectors on page 10)
• RS-485 (fieldbus) isolation : 500 VDC
Communication interfaces – Ethernet
Number : 2
Primary Ethernet interface
• Network interface : 10/100BASE-TX – Ethernet / Fast Ethernet
• Data transfer rate : Up to 100 Mbps
• Distance between devices : Up to 100 m
• Protocols : Meggitt TCP/IP proprietary protocol for communication with the
VM600 MPSx software, Modbus TCP and/or PROFINET
• Function : VM600 rack configuration and communications using the
VM600 MPSx software, fieldbus Modbus TCP communications
and/or fieldbus PROFINET communications
• Connectors : NET on CPUM card or 1 on IOCN card (see Connectors on page 10)
Secondary Ethernet interface (requires IOCN card)
• Network interface : 10/100BASE-TX – Ethernet / Fast Ethernet
• Data transfer rate : Up to 10 Mbps
• Distance between devices : Up to 100 m
• Protocols : Modbus TCP
• Function : Fieldbus Modbus TCP communications
• Connector : 2 on IOCN card (see Connectors on page 10)
Serial communications module (CPUM PC/104 slot 2)
Note: The serial communications module is optional and is only fitted to the serial redundant version of the
CPUM card.
Module type : AIM104-COM4 or equivalent
Power supply to module (input) : 5 VDC, <220 mA
Isolation : >100 VDC