Fast, easy and error-free cabinet wiring
Modular design, improves reliability
Lowers overall termination footprint
Significant labor and work reduction
Loop disconnect feature for Analog Signals
LED’s and replaceable Fuses for discrete Signals
Termination Fault Detection between discrete
traditional I/O Cards and Mass Connection
Board Signals
Introduction
The DeltaV™ S-series Mass Connection Solutions provide fast,
easy and reliable connection from field devices to DeltaV
simplex and redundant, high density traditional I/O Cards,
while providing several wiring options.
The modular design of the Mass Connection Boards further
helps to lower the overall termination footprint due to flexible
mounting capabilities.
Ribbon cable connectors will be used to connect the Mass
Connection Boards easily to the simplex or redundant, high
density traditional I/O Cards, where loop and termination
fault diagnostic information are available.
Benefits
Fast, easy way to connect terminals. The DeltaV simplex and
redundant high density traditional I/O Cards can be easily wired
to the Mass Connection Boards within seconds.
No tools are necessary to connect the ribbon cables, so you
can significantly reduce labor costs by eliminating additional
cabinet wiring.
Modular design, improves reliability. The modular designed
Mass Connection Boards are more reliable than other traditional
solution, by splitting the Signals up, to a max of 16 Signals.
Optimization of space. The DeltaV S-series Mass Connection
Solutions offer significant space advantages by integrating all
needed cabinet wiring components on one board.
Significant labor work reduction. No need for cross wiring
between I/O cards and Mass Connection Boards anymore, due
to flexible 1:1 ribbon cable based connectivity.
Significant cost reduction. Since off-the-shelf Ribbon cables
can be used inside a Cabinet with a max. Length of 3 m,
significant cost reductions can be achieved.
In some cases, longer cables are needed for connections
between two Cabinets. 6m long Standard Round Ribbon Cables
can be ordered to be used with the Mass Connection Solutions.
Loop Disconnect Features for all Signal Types. For each
Signal Type, a loop disconnect feature is available on the Mass
Connection boards.
On the AI/AO Mass Connection boards, this is realized using a
specific knife edge disconnect setup with 2mm test holes, in
this way maintenance or calibration work can be performed
without disturbing the 4-20 mA loop based Signal.
On the DI/DO Mass Connection boards, this is realized using
replaceable fuses. In this way, loop power to the field can be
easily disconnected, during maintenance activities.
Termination Fault Detection. With the DI/DO Mass
Connection boards, power or cable failures can now be
detected by DeltaV Diagnostic when used with the new
Plus Cards.
Product Description
AI/AO Plus Mass Connection Board
The AI/AO Plus Mass Connection Board connects to the new
S-series Plus (simplex or redundant) AI, 16 Channel and AO,
16 Channel cards by using either two ribbon cables with 24-Pin
connectors or the 48-Pin special Round Ribbon Cable, which is
required if the distance is longer than 3m.
Up to 16 Analog, 4-20 mA HART based Field devices can be
connected to the AI/AO Plus Mass Connection Boards by screw
terminals. 2- And 4- wire Devices are supported by the
3- row screw architecture, so you can choose on a Channel
by Channel basis.
For each Channel, a loop disconnect feature with 2mm test
holes is implemented. In this way, maintenance or calibration
work can be performed at any time, without disturbing the
4-20 mA loop based Signal.
Please refer to the Cross Reference List for your application.
DI Mass Connection Board (for simplex DI Card)
This DI Mass Connection Solution (set of two boards) connects
to the existing simplex S-series DI, 32 Channel, 24 VDC, Dry
Contact cards by using either two ribbon cables with 20-Pin
connectors or two of the 20-Pin standard Round Ribbon Cable,
which is required if the distance is longer than 3m.
Up to 16, 24 VDC based discrete input Signals can be connected
to each of the DI Mass Connection Boards by screw terminals.
Dry Contact or 24 VDC Isolated Field Signals are supported by
the 2- row screw architecture.
Yellow LED’s are providing status Indication for each Channel,
while the replaceable fuses can be used to disconnect loop
power to the field, during maintenance activities.
Please refer to the Cross Reference List for your application.
DI Plus Mass Connection Board (for DI Plus Card)
The DI Plus Mass Connection Solution (set of two boards)
connects to the new redundant S-series Plus DI, 32 Channel,
24 VDC, Dry Contact cards by using either two ribbon cables
with 20-Pin connectors or two of the 20-Pin standard Round
Ribbon Cable, which is required if the distance is longer