REXRTOHIndraDrive Control Sections CSB02, CSE02, CSH02, CDB02

From:REXRTOH | Author:LIAO | Time :2025-08-21 | 324 Browse: | Share:

Basic design of the Rexroth IndraDrive controllers

1.2.1 General information

Power section

2 Control section

Fig. 1-1: Basic design of a Rexroth IndraDrive controller

The drive controller consists of two essential parts:

● Power section

● Control section

1.2.2 Delivery

The control section is a separate component that is plugged into the power

section. As a standard, the drive controller is supplied ex works as a com‐

plete device including the control section.

Control sections and power sections can also be ordered separately. The re‐

spective firmware package has to be simultaneously ordered for control sec‐

tions.

1.2.3 Mounting and Dismounting the Control Section

General Information

In case the control section is delivered separately, observe the following in‐

structions:

Training

Risk of damage to the control section by im‐

proper handling!

NOTICE

Only such persons trained by Rexroth for mounting and dismounting control

sections are allowed to mount and dismount control sections.

ESD Protection

Risk of damage to the control section and in‐

terference with its operational safety caused

by electrostatic charges!

NOTICE

Exposed conductive parts coming into contact with the control section must

be previously discharged by means of grounding.

Such exposed conductive parts include:

● The human body (ground connection by touching a conductive, groun‐

ded object)

● Parts and tools (place them on a conductive support)

Control sections may only be stored or dispatched in conductive packaging.

Limited Number of Plug-In Actions

Risk of damage to the control section or pow‐

er section by mounting and dismounting the

control section too often!

NOTICE

For a drive controller, the control section must not be mounted and dismoun‐

ted more than a maximum of 20 times.

12/143 Bosch Rexroth AG DOK-INDRV*-CXX02******-PR03-EN-P

IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02

In

Important directions for use

2.1 Appropriate use

2.1.1 Introduction

Rexroth products reflect the state-of-the-art in their development and their

manufacture. They are tested prior to delivery to ensure operating safety and

reliability.

Personal injury and property damage caused

by incorrect use of the products!

WARNING

The products have been designed for use in industrial environments and may

only be used in the appropriate way. If they are not used in the appropriate

way, situations resulting in property damage and personal injury can occur.

Rexroth as manufacturer is not liable for any damages resulting

from inappropriate use. In such cases, the guarantee and the

right to payment of damages resulting from inappropriate use are

forfeited. The user alone carries all responsibility of the risks.

Before using Rexroth products, the following pre-requisites must be met to

ensure appropriate use of the products:

● Personnel that in any way, shape or form uses our products must first

read and understand the relevant safety instructions and be familiar with

their appropriate use.

● If the products take the form of hardware, then they must remain in their

original state, in other words, no structural changes are permitted. It is

not permitted to decompile software products or alter source codes.

● Damaged or faulty products may not be installed or put into operation.

● Make sure that the products have been installed in the manner descri‐

bed in the relevant documentation.

2.1.2 Areas of use and application

Drive controllers made by Rexroth are designed to control electrical motors

and monitor their operation.

Control and monitoring of the Drive controllers may require additional sensors

and actors.

The drive controllers may only be used with the accessories and

parts specified in this documentation. If a component has not

been specifically named, then it may neither be mounted nor con‐

nected. The same applies to cables and lines.

Operation is only permitted in the specified configurations and

combinations of components using the software and firmware as

specified in the relevant Functional Descriptions.

Drive controllers have to be programmed before commissioning to ensure

that the motor executes the specific functions of an application.

Drive controllers of the Rexroth IndraDrive line have been developed for use

in single- and multi-axis drive and control tasks.

To ensure application-specific use of Drive controllers, device types of differ‐

ent drive power and different interfaces are available.

Typical applications include, for example:

● Handling and mounting systems,

● Packaging and food machines,

● Printing and paper processing machines and

● Machine tools.

Drive controllers may only be operated under the assembly and installation

conditions described in this documentation, in the specified position of normal

use and under the ambient conditions as described (temperature, degree of

protection, humidity, EMC, etc.).

2.2 Inappropriate use

Using the Drive controllers outside of the operating conditions described in

this documentation and outside of the technical data and specifications given

is defined as "inappropriate use".

Drive controllers may not be used, if ...

● they are subject to operating conditions that do not meet the specified

ambient conditions. This includes, for example, operation under water,

under extreme temperature fluctuations or extremely high maximum

temperatures.

● Furthermore, Drive controllers may not be used in applications which

have not been expressly authorized by Rexroth. Please carefully follow

the specifications outlined in the general Safety Instructions!

Components of the Rexroth IndraDrive system are products of

category C3 (with limited availability) according to IEC 61800‑3.

To ensure that this category (limit values) is maintained, suitable

line filters must be used in the drive system.

These components are not provided for use in a public low-volt‐

age network supplying residential areas with power. If these com‐

ponents are used in such a public network, high-frequency inter‐

ference is to be expected. This can require additional measures

of radio interference suppression.

Safety instructions for electric drives and controls

3.1 Definitions of terms

Application Documentation Application documentation comprises the entire documentation used to in‐

form the user of the product about the use and safety-relevant features for

configuring, integrating, installing, mounting, commissioning, operating, main‐

taining, repairing and decommissioning the product. The following terms are

also used for this kind of documentation: Operating Instructions, Commis‐

sioning Manual, Instruction Manual, Project Planning Manual, Application De‐

scription, etc.

Component A component is a combination of elements with a specified function, which

are part of a piece of equipment, device or system. Components of the elec‐

tric drive and control system are, for example, supply units, drive controllers,

mains choke, mains filter, motors, cables, etc.

Control system A control system comprises several interconnected control components

placed on the market as a single functional unit.

Device A device is a finished product with a defined function, intended for users and

placed on the market as an individual piece of merchandise.

Electrical equipment Electrical equipment encompasses all devices used to generate, convert,

transmit, distribute or apply electrical energy, such as electric motors, trans‐

formers, switching devices, cables, lines, power-consuming devices, circuit

board assemblies, plug-in units, control cabinets, etc.

Electric drive system An electric drive system comprises all components from mains supply to mo‐

tor shaft; this includes, for example, electric motor(s), motor encoder(s), sup‐

ply units and drive controllers, as well as auxiliary and additional compo‐

nents, such as mains filter, mains choke and the corresponding lines and ca‐

bles.

Installation An installation consists of several devices or systems interconnected for a

defined purpose and on a defined site which, however, are not intended to be

placed on the market as a single functional unit.

Machine A machine is the entirety of interconnected parts or units at least one of

which is movable. Thus, a machine consists of the appropriate machine drive

elements, as well as control and power circuits, which have been assembled

for a specific application. A machine is, for example, intended for processing,

treatment, movement or packaging of a material. The term "machine" also

covers a combination of machines which are arranged and controlled in such

a way that they function as a unified whole.

Manufacturer The manufacturer is an individual or legal entity bearing responsibility for the

design and manufacture of a product which is placed on the market in the in‐

dividual's or legal entity's name. The manufacturer can use finished products,

finished parts or finished elements, or contract out work to subcontractors.

However, the manufacturer must always have overall control and possess

the required authority to take responsibility for the product.

Product Examples of a product: Device, component, part, system, software, firmware,

among other things.

Project planning manual A project planning manual is part of the application documentation used to

support the sizing and planning of systems, machines or installations.

Qualified persons In terms of this application documentation, qualified persons are those per‐

sons who are familiar with the installation, mounting, commissioning and op‐

eration of the components of the electric drive and control system, as well as

with the hazards this implies, and who possess the qualifications their work

requires. To comply with these qualifications, it is necessary, among other

things,

● to be trained, instructed or authorized to switch electric circuits and devi‐

ces safely on and off, to ground them and to mark them.

● to be trained or instructed to maintain and use adequate safety equip‐

ment.

● to attend a course of instruction in first aid.

User A user is a person installing, commissioning or using a product which has

been placed on the market.

3.2 General information

3.2.1 Using the Safety instructions and passing them on to others

Do not attempt to install and operate the components of the electric drive and

control system without first reading all documentation provided with the prod‐

uct. Read and understand these safety instructions and all user documenta‐

tion prior to working with these components. If you do not have the user doc‐

umentation for the components, contact your responsible Rexroth sales part‐

ner. Ask for these documents to be sent immediately to the person or per‐

sons responsible for the safe operation of the components.

If the component is resold, rented and/or passed on to others in any other

form, these safety instructions must be delivered with the component in the

official language of the user's country.

Improper use of these components, failure to follow the safety instructions in

this document or tampering with the product, including disabling of safety de‐

vices, could result in property damage, injury, electric shock or even death.

3.2.2 Requirements for safe use

Read the following instructions before initial commissioning of the compo‐

nents of the electric drive and control system in order to eliminate the risk of

injury and/or property damage. You must follow these safety instructions.

● Rexroth is not liable for damages resulting from failure to observe the

safety instructions.

● Read the operating, maintenance and safety instructions in your lan‐

guage before commissioning. If you find that you cannot completely un‐

derstand the application documentation in the available language,

please ask your supplier to clarify.

● Proper and correct transport, storage, mounting and installation, as well

as care in operation and maintenance, are prerequisites for optimal and

safe operation of the component.

● Only qualified persons may work with components of the electric drive

and control system or within its proximity.

● Only use accessories and spare parts approved by Rexroth.

● Follow the safety regulations and requirements of the country in which

the components of the electric drive and control system are operated.

● Only use the components of the electric drive and control system in the

manner that is defined as appropriate. See chapter "Appropriate Use".

● The ambient and operating conditions given in the available application

documentation must be observed.

16/143 Bosch Rexroth AG DOK-INDRV*-CXX02******-PR03-EN-P

IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02

S

Safety instructions for electric drives and controls

Applications for functional safety are only allowed if clearly and explicitly

specified in the application documentation "Integrated Safety Technolo‐

gy". If this is not the case, they are excluded. Functional safety is a safe‐

ty concept in which measures of risk reduction for personal safety de‐

pend on electrical, electronic or programmable control systems.

● The information given in the application documentation with regard to

the use of the delivered components contains only examples of applica‐

tions and suggestions.

The machine and installation manufacturers must

– make sure that the delivered components are suited for their indi‐

vidual application and check the information given in this applica‐

tion documentation with regard to the use of the components,

– make sure that their individual application complies with the appli‐

cable safety regulations and standards and carry out the required

measures, modifications and complements.

● Commissioning of the delivered components is only allowed once it is

sure that the machine or installation in which the components are instal‐

led complies with the national regulations, safety specifications and

standards of the application.

● Operation is only allowed if the national EMC regulations for the applica‐

tion are met.

● The instructions for installation in accordance with EMC requirements

can be found in the section on EMC in the respective application docu‐

mentation.

The machine or installation manufacturer is responsible for compliance

with the limit values as prescribed in the national regulations.

● The technical data, connection and installation conditions of the compo‐

nents are specified in the respective application documentations and

must be followed at all times.

National regulations which the user has to comply with

● European countries: In accordance with European EN standards

● United States of America (USA):

– National Electrical Code (NEC)

– National Electrical Manufacturers Association (NEMA), as well as

local engineering regulations

– Regulations of the National Fire Protection Association (NFPA)

● Canada: Canadian Standards Association (CSA)

● Other countries:

– International Organization for Standardization (ISO)

– International Electrotechnical Commission (IEC)

3.2.3 Hazards by improper use

● High electrical voltage and high working current! Danger to life or seri‐

ous injury by electric shock!

● High electrical voltage by incorrect connection! Danger to life or injury by

electric shock!

● Dangerous movements! Danger to life, serious injury or property dam‐

age by unintended motor movements!

● Health hazard for persons with heart pacemakers, metal implants and

hearing aids in proximity to electric drive systems!

● Risk of burns by hot housing surfaces!

● Risk of injury by improper handling! Injury by crushing, shearing, cutting,

hitting!

● Risk of injury by improper handling of batteries!

● Risk of injury by improper handling of pressurized lines!

3.3 Instructions with regard to specific dangers

3.3.1 Protection against contact with electrical parts and housings

This section concerns components of the electric drive and con‐

trol system with voltages of more than 50 volts.

Contact with parts conducting voltages above 50 volts can cause personal

danger and electric shock. When operating components of the electric drive

and control system, it is unavoidable that some parts of these components

conduct dangerous voltage.

High electrical voltage! Danger to life, risk of injury by electric shock or seri‐

ous injury!

● Only qualified persons are allowed to operate, maintain and/or repair the

components of the electric drive and control system.

● Follow the general installation and safety regulations when working on

power installations.

● Before switching on, the equipment grounding conductor must have

been permanently connected to all electric components in accordance

with the connection diagram.

● Even for brief measurements or tests, operation is only allowed if the

equipment grounding conductor has been permanently connected to the

points of the components provided for this purpose.

● Before accessing electrical parts with voltage potentials higher than

50 V, you must disconnect electric components from the mains or from

the power supply unit. Secure the electric component from reconnec‐

tion.

● With electric components, observe the following aspects:

Always wait 30 minutes after switching off power to allow live capacitors

to discharge before accessing an electric component. Measure the elec‐

trical voltage of live parts before beginning to work to make sure that the

equipment is safe to touch.

● Install the covers and guards provided for this purpose before switching

on.

● Never touch any electrical connection points of the components while

power is turned on.

● Do not remove or plug in connectors when the component has been

powered.

● Under specific conditions, electric drive systems can be operated at

mains protected by residual-current-operated circuit-breakers sensitive

to universal current (RCDs/RCMs).

18/143 Bosch Rexroth AG DOK-INDRV*-CXX02******-PR03-EN-P

IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02

S

● Secure built-in devices from penetrating foreign objects and water, as

well as from direct contact, by providing an external housing, for exam‐

ple a control cabinet.

High housing voltage and high leakage current! Danger to life, risk of injury

by electric shock!

● Before switching on and before commissioning, ground or connect the

components of the electric drive and control system to the equipment

grounding conductor at the grounding points.

● Connect the equipment grounding conductor of the components of the

electric drive and control system permanently to the main power supply

at all times. The leakage current is greater than 3.5 mA.

● Establish an equipment grounding connection with a minimum cross

section according to the table below. With an outer conductor cross sec‐

tion smaller than 10 mm2

 (8 AWG), the alternative connection of two

equipment grounding conductors is allowed, each having the same

cross section as the outer conductors.

Cross section outer con‐

ductor

Minimum cross section equipment grounding conductor

Leakage current ≥ 3.5 mA

1 equipment grounding

conductor

2 equipment grounding

conductors

1.5 mm2

 (16 AWG)

10 mm2

 (8 AWG)

2 × 1.5 mm2

 (16 AWG)

2.5 mm2

 (14 AWG) 2 × 2.5 mm2

 (14 AWG)

4 mm2

 (12 AWG) 2 × 4 mm2

 (12 AWG)

6 mm2

 (10 AWG) 2 × 6 mm2

 (10 AWG)

10 mm2

 (8 AWG) -

16 mm2

 (6 AWG)

16 mm2

 (6 AWG)

-

25 mm2

 (4 AWG) -

35 mm2

 (2 AWG) -

50 mm2

 (1/0 AWG) 25 mm2

 (4 AWG)

Protective extra-low voltage as protection against electric shock 

Protective extra-low voltage is used to allow connecting devices with basic in‐

sulation to extra-low voltage circuits.

On components of an electric drive and control system provided by Rexroth,

all connections and terminals with voltages up to 50 volts are PELV ("Protec‐

tive Extra-Low Voltage") systems. It is allowed to connect devices equipped

with basic insulation (such as programming devices, PCs, notebooks, display

units) to these connections.

Danger to life, risk of injury by electric shock! High electrical voltage by incor‐

rect connection!

If extra-low voltage circuits of devices containing voltages and circuits of

more than 50 volts (e.g., the mains connection) are connected to Rexroth

products, the connected extra-low voltage circuits must comply with the re‐

quirements for PELV ("Protective Extra-Low Voltage").

3.3.3 Protection against dangerous movements

Dangerous movements can be caused by faulty control of connected motors.

Some common examples are:

● Improper or wrong wiring or cable connection

● Operator errors

● Wrong input of parameters before commissioning

● Malfunction of sensors and encoders

● Defective components

● Software or firmware errors

These errors can occur immediately after equipment is switched on or even

after an unspecified time of trouble-free operation.

The monitoring functions in the components of the electric drive and control

system will normally be sufficient to avoid malfunction in the connected

drives. Regarding personal safety, especially the danger of injury and/or

property damage, this alone cannot be relied upon to ensure complete safety.

Until the integrated monitoring functions become effective, it must be as‐

sumed in any case that faulty drive movements will occur. The extent of faulty

drive movements depends upon the type of control and the state of opera‐

tion.

Dangerous movements! Danger to life, risk of injury, serious injury or property

damage!

A risk assessment must be prepared for the installation or machine, with its

specific conditions, in which the components of the electric drive and control

system are installed.

As a result of the risk assessment, the user must provide for monitoring func‐

tions and higher-level measures on the installation side for personal safety.

The safety regulations applicable to the installation or machine must be taken

into consideration. Unintended machine movements or other malfunctions

are possible if safety devices are disabled, bypassed or not activated.

To avoid accidents, injury and/or property damage:

● Keep free and clear of the machine’s range of motion and moving ma‐

chine parts. Prevent personnel from accidentally entering the machine’s

range of motion by using, for example:

– Safety fences

– Safety guards

– Protective coverings

– Light barriers

● Make sure the safety fences and protective coverings are strong enough

to resist maximum possible kinetic energy.

● Mount emergency stopping switches in the immediate reach of the oper‐

ator. Before commissioning, verify that the emergency stopping equip‐

ment works. Do not operate the machine if the emergency stopping

switch is not working.

● Prevent unintended start-up. Isolate the drive power connection by

means of OFF switches/OFF buttons or use a safe starting lockout.

● Make sure that the drives are brought to safe standstill before accessing

or entering the danger zone.

● Additionally secure vertical axes against falling or dropping after switch‐

ing off the motor power by, for example,

– mechanically securing the vertical axes,

– adding an external braking/arrester/clamping mechanism or

– ensuring sufficient counterbalancing of the vertical axes.

● The standard equipment motor holding brake or an external holding

brake controlled by the drive controller is not sufficient to guarantee per‐

sonal safety!

● Disconnect electrical power to the components of the electric drive and

control system using the master switch and secure them from reconnec‐

tion ("lock out") for:

– Maintenance and repair work

– Cleaning of equipment

– Long periods of discontinued equipment use

● Prevent the operation of high-frequency, remote control and radio equip‐

ment near components of the electric drive and control system and their

supply leads. If the use of these devices cannot be avoided, check the

machine or installation, at initial commissioning of the electric drive and

control system, for possible malfunctions when operating such high-fre‐

quency, remote control and radio equipment in its possible positions of

normal use. It might possibly be necessary to perform a special electro‐

magnetic compatibility (EMC) test.

3.3.4 Protection against electromagnetic and magnetic fields during opera‐

tion and mounting

Electromagnetic and magnetic fields!

Hazards for persons with active medical implants or passive metallic im‐

plants, as well as for pregnant women.

● Persons with active medical implants (e.g. heart pacemakers), passive

metallic implants (e.g. hip implants) and pregnant women might possibly

risk hazards by electromagnetic or magnetic fields in the immediate vi‐

cinity of components of the electric drive and control system and the as‐

sociated current-carrying conductors.

Entering the following areas can cause danger to these persons:

– Areas in which components of the electric drive and control system

and the associated current-carrying conductors are mounted, com‐

missioned and operated.

– Areas in which parts of motors with permanent magnets are stored,

repaired or mounted.

● Before entering these areas, the above-mentioned persons should seek

advice from their physician.

● Observe the occupational safety and health regulations applicable at the

site of operation, for installations equipped with components of the elec‐

DOK-INDRV*-CXX02******-PR03-EN-P Bosch Rexroth AG 21/143

IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02

S

Protection against contact with hot parts

Hot surfaces of components of the electric drive and control system. Risk of

burns!

● Do not touch hot surfaces of, for example, braking resistors, heat sinks,

supply units and drive controllers, motors, windings and laminated

cores!

● According to the operating conditions, temperatures of the surfaces can

be higher than 60 °C (140 °F) during or after operation.

● Before touching motors after having switched them off, let them cool

down for a sufficient period of time. Cooling down can require up to 140

minutes! The time required for cooling down is approximately five times

the thermal time constant specified in the technical data.

● After switching chokes, supply units and drive controllers off, wait 15 mi‐

nutes to allow them to cool down before touching them.

● Wear safety gloves or do not work at hot surfaces.

● For certain applications, and in accordance with the respective safety

regulations, the manufacturer of the machine or installation must take

measures to avoid injuries caused by burns in the final application.

These measures can be, for example: Warnings at the machine or in‐

stallation, guards (shieldings or barriers) or safety instructions in the ap‐

plication documentation.

3.3.6 Protection during handling and mounting

Risk of injury by improper handling! Injury by crushing, shearing, cutting, hit‐

ting!

● Observe the relevant statutory regulations of accident prevention.

● Use suitable equipment for mounting and transport.

● Avoid jamming and crushing by appropriate measures.

● Always use suitable tools. Use special tools if specified.

● Use lifting equipment and tools in the correct manner.

● Use suitable protective equipment (hard hat, safety goggles, safety

shoes, safety gloves, for example).

● Do not stand under hanging loads.

● Immediately clean up any spilled liquids from the floor due to the risk of

falling!

3.3.7 Battery safety

Batteries consist of active chemicals in a solid housing. Therefore, improper

handling can cause injury or property damage.

Risk of injury by improper handling!

● Do not attempt to reactivate low batteries by heating or other methods

(risk of explosion and cauterization).

● Do not attempt to recharge the batteries as this may cause leakage or

explosion.

● Do not throw batteries into open flames.

● Do not dismantle batteries.

● When replacing the battery/batteries, do not damage the electrical parts

installed in the devices.

● Only use the battery types specified for the product.

Environmental protection and disposal! The batteries contained in

the product are considered dangerous goods during land, air, and

sea transport (risk of explosion) in the sense of the legal regula‐

tions. Dispose of used batteries separately from other waste. Ob‐

serve the national regulations of your country.

3.3.8 Protection against pressurized systems

According to the information given in the Project Planning Manuals, motors

and components cooled with liquids and compressed air can be partially sup‐

plied with externally fed, pressurized media, such as compressed air, hy‐

draulics oil, cooling liquids and cooling lubricants. Improper handling of the

connected supply systems, supply lines or connections can cause injuries or

property damage.

Risk of injury by improper handling of pressurized lines!

● Do not attempt to disconnect, open or cut pressurized lines (risk of ex‐

plosion).

● Observe the respective manufacturer's operating instructions.

● Before dismounting lines, relieve pressure and empty medium.

● Use suitable protective equipment (safety goggles, safety shoes, safety

gloves, for example).

● Immediately clean up any spilled liquids from the floor due to the risk of

falling!

Environmental protection and disposal! The agents (e.g., fluids)

used to operate the product might not be environmentally friendly.

Dispose of agents harmful to the environment separately from

other waste. Observe the national regulations of your country.

DOK-INDRV*-CXX02******-PR03-EN-P Bosch Rexroth AG 23/143

IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02

S

Explanation of signal words and the Safety alert symbol

The Safety Instructions in the available application documentation contain

specific signal words (DANGER, WARNING, CAUTION or NOTICE) and,

where required, a safety alert symbol (in accordance with

ANSI Z535.6-2011).

The signal word is meant to draw the reader's attention to the safety instruc‐

tion and identifies the hazard severity.

The safety alert symbol (a triangle with an exclamation point), which pre‐

cedes the signal words DANGER, WARNING and CAUTION, is used to alert

the reader to personal injury hazards.

DANGER 

In case of non-compliance with this safety instruction, death or serious injury

will occur.

WARNING 

In case of non-compliance with this safety instruction, death or serious injury

could occur.

CAUTION 

In case of non-compliance with this safety instruction, minor or moderate in‐

jury could occur.

NOTICE 

In case of non-compliance with this safety instruction, property damage could

occur.



  • EMERSON MVME61006E-0163R VMEbus Single-Board Computer
  • EMERSON Ovation 5X00453G01 Remote I/O Node Controller Module
  • EMERSON 5X00070G04 Analog input
  • EMERSON Ovation 5X00070G01 Analog Input Module
  • EMERSON Ovation 5X00790G01 Compact Controller Module
  • EMERSON 5X00846G01 HART analog output module
  • EMERSON 1C31113G01 Digital output module (5-60VDC)
  • EMERSON KJ4110X1-BA1 I/O terminal module
  • EMERSON CSI3125 A3125/022-020 Shaft-Vibration Monitor
  • EMERSON 5X00273G01 Digital output module
  • EMERSON KJ4001X1-NB1 12P3368X012 REV:E 1-Wide I/O Carrier Extender Left
  • EMERSON KJ4001X1-NA1 12P3373X012 REV:C 1-Wide I/O Carrier Extender Right
  • EMERSON A6312/06 Speed and Key Monitor
  • EMERSON KJ4001X1-BE1 8-Wide I/O Carrier
  • EMERSON KJ2005X1-MQ1 KJ2005X1-MQ2 13P0072X082 MQ Controller
  • EMERSON 5X00226G03 - Ovation™ I/O Interface Controller, Electronics Module
  • EMERSON PR6423/00R-010+CON031 Vibration sensor
  • EMERSON 9199-00002 A6120 Control Module
  • Emerson Ovation 1C31234G01 - Ovation™ 16 Channel Compact Digital Input
  • Emerson Ovation KJ3002X1-BF1 12P1732X042 Controller module
  • Emerson Ovation 5X00226G01 I/O Interface Module
  • Emerson Ovation™ Controller Model OCR1100(5X00481G04/5X00226G04)
  • Emerson Ovation 5X00499G01 Digital Input 24Vdc Single 32CH
  • Emerson Ovation 5X00500G01 32-Channel Digital Output Module
  • Emerson ovation VE4001S2T2B4 Analog output card
  • Emerson ovation 5X00501G01 5X00502G01 Ethernet link controller
  • EMERSON A6824R 9199-00098-13 Module
  • EMERSON A6140 9199-00058 Industrial Control Module
  • EMERSON 1C31194G03 Industrial Control Module
  • EMERSON DB1-1 Industrial Control Module
  • EMERSON PMC-IO-ADAPTER I/O module
  • EMERSON L0115012 L0115032 Control module
  • EMERSON PMC-IO-PROZESSOR Process control module
  • EMERSON PMC PROFINET Manage Gigabit Ethernet switches
  • EMERSON A3120022-000 CSI3120 Bearing-Vibration Monitor
  • EMERSON SE3008 KJ2005X1-SQ1 12P6383X032 Controller
  • EMERSON 1000554 Printed circuit board
  • EMERSON PR6423/002-041 Sensor module
  • EMERSON 1C31232G02 Westinghouse control module
  • Abaco TRRM940 Switch
  • Abaco SWE440A Switch
  • Abaco NETernity™ RM984RC Ethernet Switch
  • Abaco NETernity™ GBX411 Ethernet Switch
  • Abaco NETernity™ GBX25
  • Abaco NETernity SWE540A
  • Abaco CP3-GESW8-TM8 Ethernet switch
  • Abaco SWE440S Ethernet switch
  • Abaco SWE450S 100GbE 3U VPX Switch Aligned to SOSA™ Standard
  • Abaco SWE550S 100GbE 6U VPX Switch Aligned to SOSA™ Standard
  • Abaco SPR870A Wideband Digital Receiver/Exciter
  • Abaco SPR507B Serial FPDP XMC/PMC
  • Abaco ICS-1572A Transceiver Module
  • Abaco daq8580 FMV Compression System
  • Abaco VP868 FPGA Card
  • Abaco HPC2812 Rugged 6U VPX High Performance Computer with Dual Intel
  • Abaco VSR347D 3U VPX Rugged Virtual Secure Router
  • Abaco VSR8000 Fully Rugged, COTS System Secure Router
  • Abaco RES3000 Compact, Rugged Ethernet Switches
  • Abaco PMC238 Expansion Card
  • Abaco EXP238 PMC/XMC Expansion Card for XVB603 VME Single Board Computer
  • Abaco VME-REPEAT-A-L VMEbus Repeater Link
  • Abaco VME-4514A VME Analog I/O Input/Output Board
  • Abaco VME-3128A Analog I/O
  • Abaco VME-3125A analog-to-digital Conversion board
  • Abaco VME-3123A VME Analog I/O Input Boards
  • Abaco PMC239/F Analog input/output board
  • Abaco PEX431 Multi-fabric Switch
  • Abaco CPCI-100A-BP 2-slot IndustryPack carrier for 3U CompactPCI
  • Abaco PMC522 Serial Controller
  • Abaco PMC522/FP Serial Controller
  • Abaco VME-2170A Digital Output 32-bit optically isolated
  • Abaco VME-1129 Digital Input Board 128-bit high voltage
  • Abaco IP-OCTALPLUS232 Eight EIA-232 asynchronous serial ports
  • Abaco IP-DIGITAL482 Digital I/O with 48 TTL Channels
  • Abaco PMC523 16-Port Serial Controller
  • EMERSON CE4003S2B1 M-series Traditional I/O
  • EMERSON SE3008 DeltaV™ SQ Controller
  • EMERSON 1C31227G01 - Ovation™ 8 Channel Analog Input
  • EMERSON 1C31224G01 - Ovation™ 8 Channel Analog Input
  • ABB UNS0119A-P,V101 3BHE029154P3 3BHE029153R0101 Digital input
  • ABB 3BDH000050R1 AM811F Battery Module
  • ABB 3ASC25H705-7 Digital output board
  • ABB UDD406A 3BHE041465P201 control board
  • ABB 3BHE014967R0002 UNS 2880B-P,V2: COB PCB Assembled
  • ABB PPC380AE02 HIEE300885R0102 module
  • ABB NU8976A99 HIER466665R0099 Processor Module
  • ABB DIS0006 2RAA005802A0003G Digital Input Module
  • ABB Bailey IMDS003 infi 90 Digital Output Slave Module
  • ABB XO08R1-B4.0 Expand the output relay module
  • ABB VA-MC15-05 Controller module
  • ABB VA-3180-10 Controller module
  • ABB 72395-4-0399123 Excitation module
  • ABB PU516A 3BSE032402R1 Engineering Board - PCI
  • ABB 3BHE044481R0101 3BHE044477P3 PPE091A101 Module
  • ABB UCD224A102 Control unit
  • ABB SNAT603CNT SNAT 603 CNT Motor Control Board
  • ABB SNAT634PAC Drive board
  • ABB UAD149A0011 Servo controller
  • ABB UCD224A103 Industrial controller module
  • ABB 3BHE029154P3/3BHE029153R0101 UNS0119A-P,V101 Processor Module
  • ABB ARCOL 0338 ARCOL 0346 Solid-state motor starter
  • ABB ARCOL 0339 Solid-state motor controller
  • ABB KUC720AE01 3BHB003431R0001 3BHB000652R0001 power control drive board card
  • ABB UFC718AE01 HIEE300936R0101 Main Circuit Interface Board
  • ABB 216DB61 HESG324063R100 Input/output and trip unit module
  • ABB 3HAC17973-1 DSQC332A I/O Unit
  • ABB DSQC509 Circuit board connection unit
  • ABB DSQC346B Control module
  • ABB 3HAB9271-1 Dummy Module Drive System
  • ABB 3HAC5566-1 Robot drive system cable
  • ABB 3HAC9710-1 Heat exchanger unit
  • ABB SPBLK01 Blank Faceplate
  • ABB IMFECI2 Multifunctional control board
  • ABB IMDSO14 ,Digital Slave Output Module
  • ABB 3HAC031683-004 Cable Teach Pendant 30m
  • ABB Millmate Strip Scanner Edge Sensor PMSG12x
  • ABB Millmate Controller 400 PFXA401SF
  • ABB UAC318AE Controller module
  • ABB UNS2980c-ZV4 Medium-voltage control mainboard
  • ABB 3ASC25H204 DAPU100 Control board, I/O
  • ABB 3HAB8101-19 DSQC545A Modules Drive System
  • ABB CP-E 24/1.25 Power supply
  • ABB YYT107A RECTIFIER ROBOT MODULE
  • ABB YB560100-EA S3 Teaching device
  • ABB 3BSE002253R1 TC630 AF 100 Optical Modem
  • ABB TC625 3BSE002224R1 AF100 Coaxial Modem
  • ABB TA25DU-32M Thermal Overload Relay
  • ABB SR511 Regulator 24V/5V