Basic design of the Rexroth IndraDrive controllers
1.2.1 General information
Power section
2 Control section
Fig. 1-1: Basic design of a Rexroth IndraDrive controller
The drive controller consists of two essential parts:
● Power section
● Control section
1.2.2 Delivery
The control section is a separate component that is plugged into the power
section. As a standard, the drive controller is supplied ex works as a com‐
plete device including the control section.
Control sections and power sections can also be ordered separately. The re‐
spective firmware package has to be simultaneously ordered for control sec‐
tions.
1.2.3 Mounting and Dismounting the Control Section
General Information
In case the control section is delivered separately, observe the following in‐
structions:
Training
Risk of damage to the control section by im‐
proper handling!
NOTICE
Only such persons trained by Rexroth for mounting and dismounting control
sections are allowed to mount and dismount control sections.
ESD Protection
Risk of damage to the control section and in‐
terference with its operational safety caused
by electrostatic charges!
NOTICE
Exposed conductive parts coming into contact with the control section must
be previously discharged by means of grounding.
Such exposed conductive parts include:
● The human body (ground connection by touching a conductive, groun‐
ded object)
● Parts and tools (place them on a conductive support)
Control sections may only be stored or dispatched in conductive packaging.
Limited Number of Plug-In Actions
Risk of damage to the control section or pow‐
er section by mounting and dismounting the
control section too often!
NOTICE
For a drive controller, the control section must not be mounted and dismoun‐
ted more than a maximum of 20 times.
12/143 Bosch Rexroth AG DOK-INDRV*-CXX02******-PR03-EN-P
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
In
Important directions for use
2.1 Appropriate use
2.1.1 Introduction
Rexroth products reflect the state-of-the-art in their development and their
manufacture. They are tested prior to delivery to ensure operating safety and
reliability.
Personal injury and property damage caused
by incorrect use of the products!
WARNING
The products have been designed for use in industrial environments and may
only be used in the appropriate way. If they are not used in the appropriate
way, situations resulting in property damage and personal injury can occur.
Rexroth as manufacturer is not liable for any damages resulting
from inappropriate use. In such cases, the guarantee and the
right to payment of damages resulting from inappropriate use are
forfeited. The user alone carries all responsibility of the risks.
Before using Rexroth products, the following pre-requisites must be met to
ensure appropriate use of the products:
● Personnel that in any way, shape or form uses our products must first
read and understand the relevant safety instructions and be familiar with
their appropriate use.
● If the products take the form of hardware, then they must remain in their
original state, in other words, no structural changes are permitted. It is
not permitted to decompile software products or alter source codes.
● Damaged or faulty products may not be installed or put into operation.
● Make sure that the products have been installed in the manner descri‐
bed in the relevant documentation.
2.1.2 Areas of use and application
Drive controllers made by Rexroth are designed to control electrical motors
and monitor their operation.
Control and monitoring of the Drive controllers may require additional sensors
and actors.
The drive controllers may only be used with the accessories and
parts specified in this documentation. If a component has not
been specifically named, then it may neither be mounted nor con‐
nected. The same applies to cables and lines.
Operation is only permitted in the specified configurations and
combinations of components using the software and firmware as
specified in the relevant Functional Descriptions.
Drive controllers have to be programmed before commissioning to ensure
that the motor executes the specific functions of an application.
Drive controllers of the Rexroth IndraDrive line have been developed for use
in single- and multi-axis drive and control tasks.
To ensure application-specific use of Drive controllers, device types of differ‐
ent drive power and different interfaces are available.
Typical applications include, for example:
● Handling and mounting systems,
● Packaging and food machines,
● Printing and paper processing machines and
● Machine tools.
Drive controllers may only be operated under the assembly and installation
conditions described in this documentation, in the specified position of normal
use and under the ambient conditions as described (temperature, degree of
protection, humidity, EMC, etc.).
2.2 Inappropriate use
Using the Drive controllers outside of the operating conditions described in
this documentation and outside of the technical data and specifications given
is defined as "inappropriate use".
Drive controllers may not be used, if ...
● they are subject to operating conditions that do not meet the specified
ambient conditions. This includes, for example, operation under water,