KEY FEATURES AND BENEFITS
• From the vibro-meter® product line
• 19″ slimline rack with a standard height of 1U
• Robust metal construction
• Modular concept allows specific modules
(cards) to be added for machinery protection
or condition monitoring
• Cabinet or panel mounting
• Backplane supporting the VM600Mk2/VM600
system’s Open collector (OC) bus, and power
supply distribution
• Integrated AC-input or DC-input power supply
• Power supply check relay
APPLICATIONS
• VM600Mk2/VM600 machinery protection and/
or condition monitoring systems
DESCRIPTION
The VM600Mk2/VM600 ABE056 slimline rack is used
to house hardware for the VM600Mk2/VM600
series of machinery protection and/or condition
monitoring systems, from Meggitt’s vibro-meter®
product line.
The VM600Mk2/VM600 ABE056 slimline rack has a
standard height of 1U and provides mounting
space (rack slots) for one single-width VM600Mk2/
VM600 processing module (card pair) and a relay
module (card). This rack is particularly suitable for
industrial environments, where equipment must
be permanently installed in 19″ cabinets or
panels.
Different versions of the integrated RPS1U power
supply enable a VM600Mk2/VM600 ABE056 slimline
rack to be powered using either an external AC or
DC mains supply. Both the power supplies support
a wide input voltage range.
The rack has an integrated backplane that
provides the electrical interconnections between
the integrated power supply (RPS1U) and the
installed VM600Mk2/VM600 modules (cards). It
also includes a power supply check relay,
available at the rear of the rack, which indicates
DESCRIPTION (continued)
that the integrated power supply is operating
normally.
VM600Mk2/VM600 processing modules (cards) are
installed in the front of the rack and the
associated input/output modules (cards) are
installed in the rear. The input/output modules
(cards) provide connectors for the connection of
sensors/measurement chains and for the sharing
of various signals with external systems such as a
DCS or PLC.
In general, VM600Mk2/VM600 ABE056 slimline
racks are configured in the factory before
delivery so they are supplied ready-to-use.
Optionally, each module (card) can be
reconfigured to meet the needs of a particular
machinery monitoring application using the
appropriate software package from
Meggitt Vibro-Meter: VibroSight® or VM600 MPSx.
For further information, contact your local
Meggitt representative.
SPECIFICATIONS
General
Housing : Zinc-plated painted sheet steel
Colour : Grey white (RAL 9002)
Power supply : An integrated RPS1U power supply provides the VM600Mk2/VM600
rack itself and all installed modules (cards) with +5 VDC and
±12 VDC.
See also AC-input power supply on page 3 and DC-input power
supply on page 3.
Power supply input : The power supply input has an AC or DC connector (with an
RFI filter) and an on/off switch.
See Ordering information on page 6 for information on mains power
supply leads (power cords).
Backplane : Proprietary VM600Mk2/VM600 rack bus (Open collector (OC) bus)
for data/signal sharing between modules (cards)
Rack slots
(module (card) positions)
: Front of rack:
• 1 × slot – module (card) position 01 – for a processing module
(card) such as MPC4Mk2, XMx16, MPC4 or AMC8.
Rear of rack:
• 1 × slot – module (card) position 01 – for an associated input/
output module (card) such as IOC4Mk2, XIO16T, IOC4T or IOC8T.
• 1 × slot – module (card) position 00 – for an associated relay
module (card) such as RLC16Mk2 or RLC16.
See also Mechanical drawings on page 5.
Notes
In general, associated input/output modules (cards) are required
while relay modules (cards) are optional.
For safety reasons, any VM600Mk2/VM600 rack slot not populated
by a module (card) must be covered by a blank panel
Rack slot number coding : For modules (cards) installed in the rear of the ABE056 rack, an
electronic keying mechanism known as slot number coding is used
to help ensure that the module (card) is installed in the correct slot,
as defined by the configuration (that is, by the VibroSight® or
VM600 MPSx software).
For ABE056 racks, the rack’s slot number is configurable by DIP
switch and slot number coding requires that the rack’s slot number
is set to match the slot number used by the module (card).
Slot number coding range : 0 to 12
Slot number coding defaults : Factory assigned default values as follows:
• Slot 01 = 1 (0001 binary) for an ABE056 rack configured for use by
a VM600Mk2 system such as a VM600Mk2 MPC4Mk2 + IOC4Mk2.
• Slot 01 = 3 (0011 binary) for an ABE056 rack configured for use by
a VM600 system such as a VM600 MPC4 and IOC4T.
Notes
For a VibroSight / VM600Mk2 MPC4Mk2 + IOC4Mk2 system, the
ABE056 rack DIP switch must be set to 01, as this is the default slot
number used by the VibroSight Protect configuration software for
an ABE056 rack (VM600 – 1U).
For a VM600 MPSx / VM600 MPC4 and IOC4T system, the
ABE056 rack DIP switch is typically set to 03, as this is the default slot
number used by the VM600 MPSx configuration software for the
ABE056 rack (VM600 – 1U).
AC-input power supply
Input voltage range : 90 to 264 VAC
Input frequency range : 47 to 63 Hz
Input current : 2.5 A / 115 VAC or 1.5 A / 230 VAC
Output voltages : +5 VDC and ±12 VDC
DC-input power supply
Nominal input (line) voltage : 24 VDC
Input voltage range : 18 to 58 VDC
Input current : 3.0 A / 24 VDC
Output voltages : +5 VDC and ±12 VDC
Power supply check relay
Maximum switching voltage : ±30 VRMS / ±42.4 VAC(PEAK) or 60 VDC
Maximum switching current : 1 A
Environmental
According to IEC 60068-2 recommendations
Temperature
• Operating : 0 to 65°C (32 to 149°F)
• Storage : −40 to 85°C (−40 to 185°F)
Humidity
• Operating : 0 to 90%, non-condensing
• Storage : 0 to 95%, non-condensing
Flammability class : UL 94 HB
Indoor use : Limited to indoor use only
Approvals
Conformity : European Union (EU) declaration of conformity (CE marking).
EAC marking, Eurasian Customs Union (EACU) certificate/
declaration of conformity.
Electromagnetic compatibility : IEC/EN 61000-6-2 and IEC/EN 61000-6-4.
TR CU 020/2011.
Electrical safety : IEC/EN 61010-1.
TR CU 004/2011.
Vibration : IEC 60255-21-1 (Class 2)
Environmental management : RoHS compliant
Russian federal agency for technical
regulation and metrology (Rosstandart)
: Pattern approval certificate OC.C.28.004.A N° 60224
Physical
Dimensions : See Mechanical drawings on page 5
Weight : 2.5 kg (5.5 lb) approx.
with integrated power supply (RPS1U) and modules (cards)
To order please specify
Type Designation Ordering number (PNR)
ABE056 Different versions of the VM600Mk2 ABE056 slimline rack:
– Version with integrated AC-input power supply VM600SYSMK2/B0/C56S/D5/Hxx
– Version with integrated DC-input power supply VM600SYSMK2/B0/C56S/D2/H00
ABE056 Different versions of the VM600Mk2/VM600 ABE056 slimline rack:
– Version with integrated AC-input power supply VM600SYS/B0/C56S/D5/Hxx
– Version with integrated DC-input power supply VM600SYS/B0/C56S/D2/H00
Notes
Versions of the VM600Mk2 ABE056 slimline rack (PNR VM600SYSMK2/…) and versions of the VM600Mk2/VM600 ABE056 system rack
(PNR VM600SYS/…) are currently the same, that is, the same artwork/branding/painted finish. However, when ordering a ABE056
slimline rack with other system components as part of a complete VM600Mk2/ VM600 machinery monitoring system, then the
appropriate VM600SYS-based ordering number should be used. For example, PNR VM600SYSMK2/… should be used for VM600Mk2
systems containing modules such as the MPC4Mk2 + IOC4Mk2, whereas PNR VM600SYS/… should be used for VM600 systems
containing cards such as the MPC4/IOC4T. See also Ordering guidelines on page 7.
For the AC-input version of the VM600Mk2/VM600 ABE056 slimline rack (order option code D5), order option code Hxx is used to
specify a mains power supply lead (power cord) in accordance with the table below.
For the DC-input version of the VM600Mk2/VM600 ABE056 slimline rack (order option code D2), no mains power supply lead (power
cord) is supplied, so order option code H00 must be used. That is, “None – no mains cable” in accordance with the table below.
Mains power supply lead (power cord) order option codes (Hxx):
Order option
code Designation
Equivalent
ordering
number (PNR)
H00 None – no mains cable ---
H01 No plug – flying lead with wire-end ferrules 957.18.13.0020
HCH J plug as per SEV 1011 (Switzerland) 957.18.13.0021
HEU E+F plug as per CEE7/VII (Europe, Russia, Ukraine) 957.18.13.0022
HUK G plug as per BS 1363 (UK, Hong Kong, Malaysia, Singapore) 957.18.13.0023
HJP B plug as per JIS 8303 (Japan) 957.18.13.0024
HUS B plug as per NEMA 5-15 (United States, Canada) 957.18.13.0025
ORDERING GUIDELINES
The ordering numbers (PNRs) given in Ordering information on page 6 of this data sheet should be used when
ordering a VM600Mk2/VM600 ABE056 slimline rack as an individual system component for use as a replacement
or spare part.
However, when ordering this component with other system components as part of a complete
VM600Mk2/VM600 machinery monitoring system, then a VM600SYS-based ordering number should be used.
Contact your local Meggitt representative for further information.
Meggitt (Meggitt PLC) is a leading international engineering company, headquartered in England, that designs and delivers high-performance
components and subsystems for aerospace, defence and selected energy markets. Meggitt comprises four customer-aligned divisions:
Airframe Systems, Engine Systems, Energy & Equipment and Services & Support.
The Energy & Equipment division includes the Energy Sensing and Controls product group that specialises in sensing and monitoring solutions for a
broad range of energy infrastructure, and control valves for industrial gas turbines, primarily for the Power Generation, Oil & Gas and Services markets.
Energy & Equipment is headquartered in Switzerland (Meggitt SA) and incorporates the vibro-meter® product line, which has over 65 years of sensor
and systems expertise and is trusted by original equipment manufacturers (OEMs) globally.
All information in this document, such as descriptions, specifications, drawings, recommendations and other statements, is believed to be
reliable and is stated in good faith as being approximately correct, but is not binding on Meggitt (Meggitt SA) unless expressly agreed in
writing. Before acquiring and/or using this product, you must evaluate it and determine if it is suitable for your intended application. You
should also check our website at www.meggittsensing.com/energy for any updates to data sheets, certificates, product drawings, user
manuals, service bulletins and/or other instructions affecting the product.
Unless otherwise expressly agreed in writing with Meggitt SA, you assume all risks and liability associated with use of the product. Any
recommendations and advice given without charge, whilst given in good faith, are not binding on Meggitt SA. Meggitt (Meggitt SA) takes
no responsibility for any statements related to the product which are not contained in a current Meggitt SA publication, nor for any
statements contained in extracts, summaries, translations or any other documents not authored and produced by Meggitt SA.
The certifications and warranties applicable to the products supplied by Meggitt SA are valid only for new products purchased directly from
Meggitt SA or from an authorised distributor of Meggitt SA.
In this publication, a dot (.) is used as the decimal separator and thousands are separated by thin spaces. Example: 12345.67890.
Copyright© 2023 Meggitt SA. All rights reserved. The information contained in this document is subject to change without prior notice.