DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

MEGGITTVM600Mk2/ VM600 ABE056 slimline rack

From:MEGGITT | Author:LIAO | Time :2025-08-20 | 680 Browse: | 🔊 Click to read aloud ❚❚ ▶ | Share:

KEY FEATURES AND BENEFITS

• From the vibro-meter® product line

• 19″ slimline rack with a standard height of 1U

• Robust metal construction

• Modular concept allows specific modules 

(cards) to be added for machinery protection 

or condition monitoring

• Cabinet or panel mounting

• Backplane supporting the VM600Mk2/VM600 

system’s Open collector (OC) bus, and power 

supply distribution

• Integrated AC-input or DC-input power supply

• Power supply check relay

APPLICATIONS

• VM600Mk2/VM600 machinery protection and/

or condition monitoring systems

DESCRIPTION

The VM600Mk2/VM600 ABE056 slimline rack is used 

to house hardware for the VM600Mk2/VM600 

series of machinery protection and/or condition 

monitoring systems, from Meggitt’s vibro-meter®

product line.

The VM600Mk2/VM600 ABE056 slimline rack has a 

standard height of 1U and provides mounting 

space (rack slots) for one single-width VM600Mk2/

VM600 processing module (card pair) and a relay 

module (card). This rack is particularly suitable for 

industrial environments, where equipment must 

be permanently installed in 19″ cabinets or 

panels.

Different versions of the integrated RPS1U power 

supply enable a VM600Mk2/VM600 ABE056 slimline 

rack to be powered using either an external AC or 

DC mains supply. Both the power supplies support 

a wide input voltage range.

The rack has an integrated backplane that 

provides the electrical interconnections between 

the integrated power supply (RPS1U) and the 

installed VM600Mk2/VM600 modules (cards). It 

also includes a power supply check relay, 

available at the rear of the rack, which indicates 

DESCRIPTION (continued)

that the integrated power supply is operating 

normally.

VM600Mk2/VM600 processing modules (cards) are 

installed in the front of the rack and the 

associated input/output modules (cards) are 

installed in the rear. The input/output modules 

(cards) provide connectors for the connection of 

sensors/measurement chains and for the sharing 

of various signals with external systems such as a 

DCS or PLC.

In general, VM600Mk2/VM600 ABE056 slimline 

racks are configured in the factory before 

delivery so they are supplied ready-to-use. 

Optionally, each module (card) can be 

reconfigured to meet the needs of a particular 

machinery monitoring application using the 

appropriate software package from 

Meggitt Vibro-Meter: VibroSight® or VM600 MPSx.

For further information, contact your local 

Meggitt representative.

SPECIFICATIONS

General

Housing : Zinc-plated painted sheet steel

Colour : Grey white (RAL 9002)

Power supply : An integrated RPS1U power supply provides the VM600Mk2/VM600 

rack itself and all installed modules (cards) with +5 VDC and 

±12 VDC.

See also AC-input power supply on page 3 and DC-input power 

supply on page 3.

Power supply input : The power supply input has an AC or DC connector (with an 

RFI filter) and an on/off switch.

See Ordering information on page 6 for information on mains power 

supply leads (power cords).

Backplane : Proprietary VM600Mk2/VM600 rack bus (Open collector (OC) bus) 

for data/signal sharing between modules (cards)

Rack slots

(module (card) positions)

: Front of rack:

• 1 × slot – module (card) position 01 – for a processing module 

(card) such as MPC4Mk2, XMx16, MPC4 or AMC8.

Rear of rack:

• 1 × slot – module (card) position 01 – for an associated input/

output module (card) such as IOC4Mk2, XIO16T, IOC4T or IOC8T.

• 1 × slot – module (card) position 00 – for an associated relay 

module (card) such as RLC16Mk2 or RLC16.

See also Mechanical drawings on page 5.

Notes

In general, associated input/output modules (cards) are required 

while relay modules (cards) are optional.

For safety reasons, any VM600Mk2/VM600 rack slot not populated 

by a module (card) must be covered by a blank panel

Rack slot number coding : For modules (cards) installed in the rear of the ABE056 rack, an 

electronic keying mechanism known as slot number coding is used 

to help ensure that the module (card) is installed in the correct slot, 

as defined by the configuration (that is, by the VibroSight® or 

VM600 MPSx software).

For ABE056 racks, the rack’s slot number is configurable by DIP 

switch and slot number coding requires that the rack’s slot number 

is set to match the slot number used by the module (card).

Slot number coding range : 0 to 12

Slot number coding defaults : Factory assigned default values as follows:

• Slot 01 = 1 (0001 binary) for an ABE056 rack configured for use by 

a VM600Mk2 system such as a VM600Mk2 MPC4Mk2 + IOC4Mk2.

• Slot 01 = 3 (0011 binary) for an ABE056 rack configured for use by 

a VM600 system such as a VM600 MPC4 and IOC4T.

Notes

For a VibroSight / VM600Mk2 MPC4Mk2 + IOC4Mk2 system, the 

ABE056 rack DIP switch must be set to 01, as this is the default slot 

number used by the VibroSight Protect configuration software for 

an ABE056 rack (VM600 – 1U).

For a VM600 MPSx / VM600 MPC4 and IOC4T system, the 

ABE056 rack DIP switch is typically set to 03, as this is the default slot 

number used by the VM600 MPSx configuration software for the 

ABE056 rack (VM600 – 1U).

AC-input power supply

Input voltage range : 90 to 264 VAC

Input frequency range : 47 to 63 Hz

Input current : 2.5 A / 115 VAC or 1.5 A / 230 VAC

Output voltages : +5 VDC and ±12 VDC

DC-input power supply

Nominal input (line) voltage : 24 VDC

Input voltage range : 18 to 58 VDC

Input current : 3.0 A / 24 VDC

Output voltages : +5 VDC and ±12 VDC

Power supply check relay

Maximum switching voltage : ±30 VRMS / ±42.4 VAC(PEAK) or 60 VDC

Maximum switching current : 1 A

Environmental

According to IEC 60068-2 recommendations

Temperature

• Operating : 0 to 65°C (32 to 149°F)

• Storage : −40 to 85°C (−40 to 185°F)

Humidity

• Operating : 0 to 90%, non-condensing

• Storage : 0 to 95%, non-condensing

Flammability class : UL 94 HB

Indoor use : Limited to indoor use only

Approvals

Conformity : European Union (EU) declaration of conformity (CE marking).

EAC marking, Eurasian Customs Union (EACU) certificate/

declaration of conformity.

Electromagnetic compatibility : IEC/EN 61000-6-2 and IEC/EN 61000-6-4.

TR CU 020/2011.

Electrical safety : IEC/EN 61010-1.

TR CU 004/2011.

Vibration : IEC 60255-21-1 (Class 2)

Environmental management : RoHS compliant

Russian federal agency for technical 

regulation and metrology (Rosstandart)

: Pattern approval certificate OC.C.28.004.A N° 60224

Physical

Dimensions : See Mechanical drawings on page 5

Weight : 2.5 kg (5.5 lb) approx.

with integrated power supply (RPS1U) and modules (cards)

To order please specify

Type Designation Ordering number (PNR)

ABE056 Different versions of the VM600Mk2 ABE056 slimline rack:

– Version with integrated AC-input power supply VM600SYSMK2/B0/C56S/D5/Hxx

– Version with integrated DC-input power supply VM600SYSMK2/B0/C56S/D2/H00

ABE056 Different versions of the VM600Mk2/VM600 ABE056 slimline rack:

– Version with integrated AC-input power supply VM600SYS/B0/C56S/D5/Hxx

– Version with integrated DC-input power supply VM600SYS/B0/C56S/D2/H00

Notes

Versions of the VM600Mk2 ABE056 slimline rack (PNR VM600SYSMK2/…) and versions of the VM600Mk2/VM600 ABE056 system rack 

(PNR VM600SYS/…) are currently the same, that is, the same artwork/branding/painted finish. However, when ordering a ABE056 

slimline rack with other system components as part of a complete VM600Mk2/ VM600 machinery monitoring system, then the 

appropriate VM600SYS-based ordering number should be used. For example, PNR VM600SYSMK2/… should be used for VM600Mk2

systems containing modules such as the MPC4Mk2 + IOC4Mk2, whereas PNR VM600SYS/… should be used for VM600 systems 

containing cards such as the MPC4/IOC4T. See also Ordering guidelines on page 7.

For the AC-input version of the VM600Mk2/VM600 ABE056 slimline rack (order option code D5), order option code Hxx is used to 

specify a mains power supply lead (power cord) in accordance with the table below.

For the DC-input version of the VM600Mk2/VM600 ABE056 slimline rack (order option code D2), no mains power supply lead (power 

cord) is supplied, so order option code H00 must be used. That is, “None – no mains cable” in accordance with the table below.

Mains power supply lead (power cord) order option codes (Hxx):

Order option 

code Designation

Equivalent 

ordering 

number (PNR)

H00 None – no mains cable ---

H01 No plug – flying lead with wire-end ferrules 957.18.13.0020

HCH J plug as per SEV 1011 (Switzerland) 957.18.13.0021

HEU E+F plug as per CEE7/VII (Europe, Russia, Ukraine) 957.18.13.0022

HUK G plug as per BS 1363 (UK, Hong Kong, Malaysia, Singapore) 957.18.13.0023

HJP B plug as per JIS 8303 (Japan) 957.18.13.0024

HUS B plug as per NEMA 5-15 (United States, Canada) 957.18.13.0025

ORDERING GUIDELINES

The ordering numbers (PNRs) given in Ordering information on page 6 of this data sheet should be used when 

ordering a VM600Mk2/VM600 ABE056 slimline rack as an individual system component for use as a replacement 

or spare part.

However, when ordering this component with other system components as part of a complete

VM600Mk2/VM600 machinery monitoring system, then a VM600SYS-based ordering number should be used. 

Contact your local Meggitt representative for further information.

Meggitt (Meggitt PLC) is a leading international engineering company, headquartered in England, that designs and delivers high-performance 

components and subsystems for aerospace, defence and selected energy markets. Meggitt comprises four customer-aligned divisions: 

Airframe Systems, Engine Systems, Energy & Equipment and Services & Support.

The Energy & Equipment division includes the Energy Sensing and Controls product group that specialises in sensing and monitoring solutions for a 

broad range of energy infrastructure, and control valves for industrial gas turbines, primarily for the Power Generation, Oil & Gas and Services markets. 

Energy & Equipment is headquartered in Switzerland (Meggitt SA) and incorporates the vibro-meter® product line, which has over 65 years of sensor 

and systems expertise and is trusted by original equipment manufacturers (OEMs) globally.

All information in this document, such as descriptions, specifications, drawings, recommendations and other statements, is believed to be 

reliable and is stated in good faith as being approximately correct, but is not binding on Meggitt (Meggitt SA) unless expressly agreed in 

writing. Before acquiring and/or using this product, you must evaluate it and determine if it is suitable for your intended application. You 

should also check our website at www.meggittsensing.com/energy for any updates to data sheets, certificates, product drawings, user 

manuals, service bulletins and/or other instructions affecting the product.

Unless otherwise expressly agreed in writing with Meggitt SA, you assume all risks and liability associated with use of the product. Any 

recommendations and advice given without charge, whilst given in good faith, are not binding on Meggitt SA. Meggitt (Meggitt SA) takes 

no responsibility for any statements related to the product which are not contained in a current Meggitt SA publication, nor for any 

statements contained in extracts, summaries, translations or any other documents not authored and produced by Meggitt SA.

The certifications and warranties applicable to the products supplied by Meggitt SA are valid only for new products purchased directly from 

Meggitt SA or from an authorised distributor of Meggitt SA.

In this publication, a dot (.) is used as the decimal separator and thousands are separated by thin spaces. Example: 12345.67890.

Copyright© 2023 Meggitt SA. All rights reserved. The information contained in this document is subject to change without prior notice.


  • Beckhoff CX5620-0225    CPU module
  • Beckhoff CX5620-0220    CPU module
  • Beckhoff CX5620-0215    CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0210 CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0195    CPU module
  • Beckhoff CX5620-0190    CPU module
  • Beckhoff CX5620-0185    CPU module
  • Beckhoff CX5620-0175    CPU module
  • Beckhoff CX5620-0170    CPU module
  • Beckhoff CX5620-0163    CPU module
  • Beckhoff CX5620-0161 CPU module
  • Beckhoff CX5620-0160 CPU module
  • Beckhoff CX5620-0100 CPU module
  • Beckhoff CX5120-0195    CPU module
  • Beckhoff CX5120-0190 CPU module
  • Beckhoff CX5120-0185 CPU module
  • Beckhoff CX5120-0175 CPU module
  • Beckhoff CX5120-0170    CPU module
  • Beckhoff CX5120-0163    CPU module
  • Beckhoff CX5120-0162    CPU module,
  • Beckhoff CX5120-0161    CPU module
  • Beckhoff CX5120-0150 CPU module
  • Beckhoff CX5120-0143 CPU module
  • Beckhoff CX5120-0142 CPU module
  • Beckhoff CX5120-0141 CPU module
  • Beckhoff CX5120-0140 CPU module
  • Beckhoff CX5120-0130 CPU module
  • Beckhoff CX5120-0123 CPU module
  • Beckhoff CX5120-0122 CPU module
  • Beckhoff CX5120-0120 CPU module, Microsoft Windows Embedded Standard 7 P
  • Beckhoff CX5120-0113 CPU module
  • Beckhoff CX5120-0112 CPU module
  • Beckhoff CX5120-0111 CPU module
  • Beckhoff CX5120-0110 CPU module, Microsoft Windows Embedded Compact 7
  • Beckhoff CX5120-0100 CPU module, no operating system
  • Beckhoff C6017-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6017 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0030  | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff CX2500-M510 | Fieldbus master module
  • Beckhoff CX2500-M310 | Fieldbus master module
  • Beckhoff CX2500-B510 | Fieldbus slave module
  • Beckhoff CX2500-B310 | Fieldbus slave module PROFIBUS for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0070 | USB 3.0 module for CX20xx, CX52xx, CX53x0. CX56x0
  • Beckhoff CX2500-0062 | 2.5 Gbit Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1061 | Power over Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1060 | Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0031 | Serial Interface RS485/RS422 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0030 | Serial Interface RS232 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX5230-0195 CPU module
  • Beckhoff CX5230-0190  CPU module
  • Beckhoff CX5230-0175    CPU module,
  • Beckhoff CX5230-0170    CPU module
  • Beckhoff CX5230-0100   CPU module, no operating system, no TwinCAT
  • Beckhoff CU8130-0240 | UPS modul, battery-backed
  • Beckhoff CU8130-0120 | UPS module, battery-backed
  • Beckhoff CU8110-0120 | UPS module, capacitive
  • Beckhoff CU8110-0060 | UPS module, capacitive
  • Beckhoff CX5130-0195    CPU module
  • Beckhoff CX5130-0190    CPU module
  • Beckhoff CX5130-0185 CPU module
  • Beckhoff CX5130-0170    CPU module, Microsoft Windows 10 IoT Enterprise 2019 LTSC
  • Beckhoff  CX5130-0163 CPU module
  • Beckhoff  CX5130-0162    CPU module
  • Beckhoff CX5130-0161 CPU module
  • Beckhoff CX5130-0160    CPU module
  • Beckhoff CX5130-0155  CPU module
  • Beckhoff CX5130-0150    CPU module
  • Beckhoff CX5130-0143    CPU module
  • Beckhoff CX5130-0142 CPU module
  • Beckhoff CX5130-0140    CPU module
  • Beckhoff CX5130-0135 CPU module
  • Beckhoff CX5130-0130 CPU module
  • Beckhoff CX5130-0125  CPU module
  • Beckhoff CX5130-0123    CPU module
  • Beckhoff CX5130-0122    CPU module
  • Beckhoff CX5130-0121    CPU module
  • Beckhoff CX5130-0115    CPU module
  • Beckhoff CX5130-0113    CPU module
  • Beckhoff CX5130-0112 CPU module
  • Beckhoff CX5130-0111   CPU module
  • Beckhoff CX5130-0110 CPU module, Microsoft Windows Embedded Compact 7. no TwinCAT
  • Beckhoff CX5130-0100 CPU module, no operating system, no TwinCAT
  • DEIF FAS-113DG Synchronisation & circuit breaker closing
  • DEIF FAS-115DG Synchronisation & circuit breaker closing
  • DEIF HAS-111DG Synchronisation & circuit breaker closing
  • DEIF LSU-122DG Load sharing, paralleling & operation
  • DEIF LSU-114DG Load sharing, paralleling & operation
  • DEIF LSU-113DG Load sharing, paralleling & operation
  • DEIF LSU-112DG Load sharing, paralleling & operation
  • DEIF RMF-112D Frequency relay
  • DEIF RMC-142D Current relay
  • DEIF RMC-132D Current relay
  • DEIF RMC-131D Current relay
  • DEIF RMC-122D Current relay
  • DEIF RMC-121D Current relay
  • DEIF RMC-111D Current relay
  • DEIF MVR-V211 Busbar Protection
  • DEIF MVR-T257 Transformer Differential Protection
  • DEIF MVR-T256 Transformer Differential Protection
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Differential Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F215 Directional Feeder Protection
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF MVR-F201 Basic Feeder Protection
  • DEIF MVR-200 series Medium Voltage Relay
  • DEIF MDR-2 Multi-differential relay
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • DEIF iE 650 PLC - The most robust programmable automation controller available
  • DEIF iE 350 PLC - Programmable Automation PLC Controller
  • DEIF iE 250 PLC Versatile and modular intelligent energy PLC controller
  • DEIF PPM-3 EDG Protection and Power Management
  • DEIF AGC 3X 4198000234E AUTOMATIC GENSET CONTROLLER
  • SAUTER ASF123 Damper actuator with spring return
  • SAUTER ASF122 Damper actuator with spring return
  • SAUTER ASF113F122 Damper actuator with spring return