DCS; Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

MOLEXDocument Edition: 1.2 Date: January 17, 2012 This document applies to the SST-PB3-VME-1 and SST-PB3-VME-2 interface cards. Copyright ©2012 Molex Inc. This document and its contents are the proprietary and confidential property of Molex Inc. and/or i

From:MOLEX | Author:LIAO | Time :2025-08-20 | 293 Browse: | Share:

Document Edition: 1.2

Date: January 17, 2012

This document applies to the SST-PB3-VME-1 and SST-PB3-VME-2 interface cards.

Copyright ©2012 Molex Inc.

This document and its contents are the proprietary and confidential property of Molex Inc. and/or 

its related companies and may not be used or disclosed to others without the express prior written 

consent of Molex Inc. and/or its related companies.

SST is a trademark of Molex Inc. All other trademarks belong to their respective companies.

At Molex, we strive to ensure accuracy in our documentation. However, due to rapidly evolving 

products, software or hardware changes occasionally may not be reflected in our documents. If 

you notice any inaccuracies, please contact us (see Appendix A of this document).

Written and designed at:

Molex Incorporated

216 Bathurst Drive

Waterloo, Ontario, Canada N2V 2L7

Hardcopies are not controlled.

Purpose of this Guide

This guide contains technical and product-related information on the SST-PB3-VME-1

and SST-PB3-VME-2 network interface cards. 

The SST-PB3-VME-1 consists of a single Profibus network interface (or channel), and the 

SST-PB3-VME-2 comprises two independent interfaces, controlled by independent CPUs. 

Each CPU executes downloadable application firmware modules, which enable application-level 

product behavior. For more details, refer to relevant firmware documentation.

Note

An application running on one channel does not affect the performance 

of other channels, as it does not share memory or processor resources 

with them.

Note

In this manual, the SST-PB3-VME-1 and SST-PB3-VME-2 will be 

referred to as the card, except where product differences apply.

Conventions

This guide uses stylistic conventions, special terms, and special notation to help enhance your 

understanding.

Style

The following stylistic conventions are used throughout this guide:

Bold indicates field names, button names, tab names, and options or selections

Italics indicates keywords (indexed) or instances of new terms and/or specialized 

words that need emphasis

CAPS indicates a specific key selection, such as ENTER, TAB, CTRL, ALT, 

DELETE

Code Font indicates command line entries or text that you would type into a field

Underlining indicates a hyperlink

“>” delimiter indicates how to navigate through a hierarchy of menu selections/options

“0x” or “-H” indicates a hexadecimal value

Terminology

The following special terms are used throughout this guide:

Card the SST-PB3-VME-1 or SST-PB3-VME-2 network interface card

Channel a Profibus network interface on the card

Firmware Module the embedded software module that gets loaded to the card’s 

memory and runs on the card. This is the operating system of the 

card, enabling it to respond to commands from the host and 

manage network communications.

Host the computer system in which the card is installed

.bin an unencrypted firmware module for the card

.ss3 an encrypted firmware module for the card

Special Notation

The following special notations are used throughout this guide:

Warning

Warning messages alert the reader to situations where personal injury 

may result. Warnings are accompanied by the symbol shown, and 

precede the topic to which they refer.

Caution

Caution messages alert the reader to situations where equipment damage 

may result. Cautions are accompanied by the symbol shown, and 

precede the topic to which they refer.

Note

A note provides additional information, emphasizes a point, or gives a 

tip for easier operation. Notes are accompanied by the symbol shown, 

and follow the text to which they refer.

Warnings and Cautions

The card is an electrical component and must be treated with the following precautions:

Warning

Only qualified electrical personnel familiar with the construction/

operation of this equipment and the hazards involved should install, 

adjust, operate, and/or service this equipment. Read and understand this 

guide in its entirety before proceeding. Failure to observe this precaution 

could result in severe bodily injury or, in extreme cases, loss of life.

Warning

You must provide an external, hand-wired emergency stop circuit 

outside the programmable controller circuitry. This circuit must disable 

the system in case of improper operation. Uncontrolled machine motion 

may result if this procedure is not followed. Failure to observe this 

precaution could result in bodily injury.

Caution

The card contains static-sensitive components. Careless handling may 

severely damage the card. Do not touch any of the connectors or pins on 

the card. When not in use, the card should be stored in an anti-static bag. 

Failure to observe this precaution could result in damage to or 

destruction of the equipment.

1.2 Card Features

The card is a VME interface for communication with Profibus networks. Each channel can:

• Act as a DP master

• Act as a DP slave 

• Send and receive FDL (layer 2) messages

• Support Master Class 1 and Master Class 2 messaging

• Support simultaneous operation in all of the above modes

• Support the standard Profibus baud rates of 9.6K, 19.2K, 93.75K, 187.5K, 500K, 1.5M, 

  • UNIOP MKDR-04-0021 Monochrome LCD (with Contrast Control)
  • UNIOP eTOP03-0046 Monochrome LCD (STN)
  • UNIOP MKDR-16-TA-0045 HMI TOUCH SCREEN
  • UNIOP Operator Interface Display MD02R-04-0042
  • UniOP Display Screen eTOP20C-0050 eTOP20C
  • UniOp eTOP05-0045 eTOP05. eTOP05P Operator Interface Touch Panel
  • UNIOP ETOP11-0050 HMI 5.6Color Operator Interface Touch Panel
  • UniOp eTOP306 Panel
  • UniOP CP04F-04-0045 Human Machine Interface
  • UniOP eTOP308 ETOP308U301 HMI Panel
  • UniOP MD00R-02-0045 Ultra-Compact Industrial Operator Terminal
  • UniOP ePALM10-0061 Handheld Robot Trainer
  • ​UniOP CP05R-04-0045 High-Value Character Operator Terminal
  • UniOP CP01R-04. CP05R-04 and CP01F-02
  • Uniop MD02R-04 - MD02R-04-0045 Industrial PLC Workstation
  • Uniop Cp02r-04-0021 Operating Interface
  • UniOP CP04F-04-1945 Rugged VFD Operator Interface
  • UniOP ECT-16-0045 High-Performance Color Touchscreen HMI
  • UniOP ERT-16-0042 High-Durability Industrial Operator Interface
  • UniOP ePAD04-0046 Compact Industrial Interface
  • UniOP BKDR-16 High-Reliability Monochrome Operator Interface
  • UniOP MKDR-04-004 Control Unit Panel
  • UniOP eTOP515 Series 500 HMI
  • Woodward 8200-1300 High-Precision 505D Steam Turbine Controller
  • ABB PFSK138 3BSE016323R3 High-Performance Digital Board Connection Unit
  • ABB PFSK163 3BSE000435R1 High-Performance Interface Module
  • UniOP ETT-VGA Human-Machine Interface (HMI) terminal
  • ABB PFSK165 3BSE027778R1 VP74201-933CW07 Signal Processing and Communication Unit
  • ABB PFSK164 3BSE021180R1 Tension sensor module and processing board
  • ABB 3BSE006505R1 PFSK 142 Control board
  • ABB PFSK160A 3BSE009514R1 Regulated High-Capacity 24V DC
  • ABB PFSK162 3BSE015088R1 High-performance signal conditioning and processing board
  • ABB PFSK152 3BSE018877R1 Signal concentrator board
  • ALSTOM PIB1201A 3BEC0067 Power Interface Board (PIB)
  • ALSTOM PIB310 3BHB0190 Adapter Module / Printed Circuit Board (PCB)
  • ALSTOM PIB102A 3BEB0180 Communication Card / PCB Module
  • ALSTOM BGTR8HE 24491276A1004 High-Frequency Power Controller / Rack Module
  • ALSTOM AM164 Analog Output / Remote I/O
  • ALSTOM UT150-1 PID temperature controller / process control board
  • ALSTOM AL132 AL132A STO0982E01 Control Motherboard / CPU Card
  • ALSTOM AS111-1 Analog Output (AO) Module
  • ALSTOM AH116-2 Servo Drive / Control Module
  • ALSTOM V4555724-0100 Electromechanical Contactor /Power Switch
  • WATLOW 999D,999A Digital/Analog Dual-Channel Base Unit
  • WATLOW 998D 998A Digital/Analog Dual-Channel Base Unit
  • WATLOW 999D-11FF-AARG Dual-channel digital unit with universal process outputs
  • WATLOW Wattlo 998D-22KK-ARRG is a high-performance dual-channel digital controller.
  • WATLOW 996A Single-loop controller
  • WATLOW 996D-11CC-CUGR Single-loop digital controller
  • WATLOW 996D Single-Channel Digital Temperature/Process Controller
  • WATLOW 997D Digital Dual-Channel Base Unit
  • WATLOW 997A Analog Dual-Channel Variant
  • WATLOW DAC / SDAC,Digital-to-Analog / Serial-to-Analog Modules
  • WATLOW MLS300-OIT Operator Interface Terminal (Keypad/Display),Discontinued
  • WATLOW CIM300 Communication Interface Module (EIA-232/485),Discontinued
  • WATLOW MLS300-CIM Control Interface Module (Comm Bridge),Discontinued
  • WATLOW MLS300-AIM,Analog Input Module (16-channel expansion),Discontinued
  • WATLOW MLS300-PM Processor Module (Central CPU),Discontinued
  • Watlow MLS332 32-Loop Processor Base Unit,Discontinued
  • Watlow MLS316 Multi-loop thermal controller
  • Watlow CLS208 C10000CP high-performance, 8-loop PID temperature controller
  • Watlow CAS 16CLS/CAS Multi-loop temperature controller
  • HIMA K9212 Module Overview
  • ABB CP555 1SBP260179R1001 Product Overview
  • Watlow MLS300 Multi-Loop Control System
  • Watlow 997D-11CC-JURG SERIES 997 Vertical Limit Control
  • Watlow CLS216 | Multi-Loop PID Temperature Controller
  • Watlow NLS300-CIM316 Multi-Loop Control Interface Module
  • Watlow PPC-TB50 (30280-00) Precision Power Controller
  • ABB PPD113-B03-23-111615 high-performance Processor / Controller Module
  • ABB MB510 3BSE002540R1 Control System Accessory
  • ABB 3BSE000863R1 SR511 Power Supply
  • ABB 3BSE014227R1 RF533 Central Unit
  • ABB PDD500A101 high-performance Drive Board / Processor Module
  • ABB PPD512A10-150000 high-performance Controller/Processor Module
  • ABB 500BIO01 1MRB150005R0001 1MRB200060/E Binary Input/Output (Combined)
  • ABB 500BIM01-1MRB160024R0002 Binary (Digital) Input Module
  • ABB 500PSM03 1MRB150038R1 894-030375D 136-011100H Power Supply Module
  • ABB 500PSM02 1MRB150015R1 AD-272.100.20-01 AZ:C Power Supply Module
  • ABB 500AIM02 1MRB150022R001 1HDF 930412 X010 Analog Input Module (AIM)
  • ABB 500MTM02 1MRB150020R0712 1HDF 930512 X010 Multivariable Transmitter Module
  • ABB 500SCM01 1MRB150004R0001 1MRB200059/C Signal Regulation and Monitoring Module
  • ABB 500TRM02 1MRB150011R0001 Terminal/Input-Output Board
  • ABB 500CPU03 1HDF700003R5122 Central Processing Unit module
  • ABB 500PB101 1MRB178009R0001 1MRB200064/C Communication Module
  • ABB 500CSP04 HE401314/0002 1MRB150051R2 Control and System Processing Module
  • ABB 500CMP04 HE401314/0001 1MRB150051R1 Communication motherboard
  • ABB 500TTM02 1MB150021R01161HF930712X010 Temperature / Logic Interface Module
  • ABB DSAO110 57120001-AT/1 Analog Output 4 Channels
  • ABB UNS4684A-P,V.1 HIEE305114R00R0001 Overvoltage protection (OVP) and pulse coupling panel (PCP) module
  • ABB PVD164A2059 3BHE014340R2059 high-performance Excitation Processor Module
  • ABB PFCL201CE 10KN 3BSX105983-100 Pressductor® Curved Plate Force Sensor
  • ABB 500SCM01 1MRB200059/C 1MRB15004R0001 Control Module
  • ABB 500CPU05 1MRB150081R1/E Central Processing Unit module
  • ABB 500CIM05 1MRB150077R1/B Communication Interface Module
  • ABB 500BIO01 1MRB150005R1/J high-performance Binary Input/Output (BIO) module
  • Metso D201379L ACN RT Controller / Processor
  • Metso D201505 (ACN C20 Controller)
  • Metso D201463 high-performance Network Controller / Processor Module
  • Metso D201505R (ACN C20 Series)
  • Metso D201380 CPU / Processor Module
  • Metso D202275 ACN Communication / Gateway Node
  • Metso D201376 ACN RT (Real-Time) Controller Node
  • METSO D200175 Application Control Node (ACN) Proc
  • METSO D200137 high-performance controller module
  • METSO IOP111 Analog Input Module
  • METSO IOP353 Digital Output Module
  • METSO IOP304 high-performance Thermocouple (TC) / Millivolt (mV) Input Module
  • METSO PDP601 high-performance Distributed Processing Unit
  • METSO IOP345 Digital Input/Output Module
  • METSO DPU-MR high-performance Distributed Processing Unit
  • METSO IOP114 high-precision Analog Input Module
  • METSO IOT300A Terminal substrate / Interface module
  • Metso R/I-TB 9139041 nput/output (I/O) interface module
  • YOKOGAWA YS1700-100/A06/A31 Programmable Logic Controller
  • YOKOGAWA PW482-10 AC Input Power Module
  • YOKOGAWA SCP451-11 CPU
  • YOKOGAWA SR1030B62 high-precision Power Supply Unit (PSU)
  • YOKOGAWA AAI143-H50 high-density Analog Input Module
  • YOKOGAWA AMM42 high-density Analog Input/Output Module
  • YOKOGAWA SDV144-S63 Digital input module
  • YOKOGAWA AIP830-111 Operating keyboard
  • YOKOGAWA S9361DH-00 High-performance terminal board module
  • YOKOGAWA ATK4A-00 S1 Terminal block adapter
  • YOKOGAWA PW701 Power Supply Module
  • YOKOGAWA AVR10D-A22010 Bus Converter
  • YOKOGAWA PROFIBUS-DP communication module
  • YOKOGAWA AIP578 AIP591 Optical link transceiver module