operation of XMx16 + XIO16T modules for
condition monitoring and/or combustion
monitoring, including the processing and
presentation of measurement data for analysis.
VibroSight is also used to configure and manage
CPUMMk2 + IOCNMk2 modules.
Refer to the VibroSight® machinery monitoring
system software data sheet for further information.
VibroSight® / VM600Mk2 MPC4Mk2
condition monitoring licensing
In VibroSight® / VM600Mk2 MPC4Mk2 systems, the
MPC4Mk2 + IOC4Mk2 module can provide
machinery protection system (MPS) functionality
and/or condition monitoring system (CMS)
functionality, depending on the requirements of
the application.
For the VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery
protection and condition monitoring module,
machinery protection functionality is available by
default for all versions of the module, while
condition monitoring functionality is optional.
Accordingly, MPC4Mk2 condition monitoring can
be used by either (1) ordering a version of the
module with condition monitoring enabled or (2)
ordering and uploading a condition monitoring
license to a version of the module without
condition monitoring enabled (using
VibroSight System Manager).
Note: MPC4Mk2 condition monitoring also requires
a VibroSight® software edition / license that
supports condition monitoring.
For example, a VibroSight / VM600Mk2 MPC4Mk2
system consisting of MPC4Mk2 + IOC4Mk2 modules
can initially be installed and used as a MPS only.
Then, CMS functionality can be quickly and easily
added at any time by upgrading the licenses for
the MPC4Mk2 + IOC4Mk2 module(s) and for
VibroSight software, as required.
Applications information
As part of a VibroSight® / VM600Mk2 system,
MPC4Mk2 + IOC4Mk2 machinery protection and
condition monitoring modules are ideal for the
protection and/or condition monitoring of critical
assets such as gas, steam or hydro turbines and
other high-value rotating machines in a wide
range of industrial applications.
For further information, contact your local
Meggitt representative.
Supported sensors
Currently available : Compatible with a wide range of sensors and measurement chains
with current (2-wire) or voltage (3-wire) outputs, including the
following sensors from the Meggitt vibro-meter® product line:
• CAxxx vibration sensors (piezoelectric accelerometers)
• CExxx and PVxxx vibration sensors (piezoelectric accelerometers
and velocity sensors)
• CVxxx and VExxx vibration sensors (velocity sensors)
• CPxxx dynamic pressure sensors (piezoelectric pressure sensors)
• TQxxx proximity sensors
• LSxxx air-gap sensors.
Dynamic inputs
Number of channels : 4 (independent channels)
Voltage inputs
• DC measurement range : 0 to +20 VDC or 0 to −20 VDC.
Note: 10 Hz DC filter (see DC filtering on page 5).
• AC measurement range : ±20 VPEAK-PEAK
• AC + DC measurement range : ±24 VPEAK-PEAK
Common-mode voltage range : −50 to +50 VDC
Common-mode rejection ratio (CMRR) : >55 dB, up to 60 Hz.
>60 dB, from 45 to 65 Hz.
Current inputs
• DC measurement range : 0 to 35 mA
• AC measurement range : ±30 mAPEAK-PEAK
• AC + DC measurement range : ±50 mAPEAK-PEAK
Frequency bandwidth : DC to 20 kHz
Input impedance
• Voltage : ≥100 kΩ, between the differential (high and low) inputs
• Current : 200 Ω ±0.2%
Accuracy
• Amplitude : ±1% of full scale
• Phase : ±1° from 10 Hz to 2 kHz.
±15° from 2 to 20 kHz.
Dynamic input range : ≥80 dB, from 3 Hz to 20 kHz
DC filtering
DC filter
• Cutoff frequency (−3 dB) : 10 Hz ±3.5 Hz
• Roll-off : −40 dB/decade (second order)
Note: The DC filter is used to extract the DC part of a dynamic input when it is configured as a DC input.
High-pass filtering
High-pass filter
• Cutoff frequency (−3 dB) : 0.1, 1 or 3 Hz (or bypassed)
• Roll-off : −20 dB/decade (first order)
• Phase error : <1° at 100 times the cutoff frequency (10, 100 or 300 Hz)
Note: The high-pass filter is used to configure a dynamic input for an AC only input signal with one of 3 different
cutoff frequencies. This filter can be disabled in order to allow the DC-coupling of the input signal (AC + DC).
Auxiliary inputs
Number of channels : 2 (independent channels)
configurable as either tachometer inputs or DC inputs
Common-mode voltage range : −50 to +50 VDC
Common-mode rejection ratio (CMRR) : >50 dB, up to 60 Hz.
>55 dB, from 45 to 65 Hz.
Tachometer input
• Triggering method : Crossing of threshold on rising edge or falling edge of signal
• Triggering threshold : 2/3 of peak-peak value ±10% for rising edge.
1/3 of peak-peak value ±10% for falling edge.
• Tachometer pulse acquisition/
detection (on input)
: Up to 51.2 kHz.
• Speed / frequency measurement
range
: 1 to 100000 RPM / 0.01667 to 1666.67 Hz.
Note: Configurable tacho divider of 1 to 255 (pulses per revolution).
• Voltage range : 0.6 to 50 VPEAK-PEAK from 2 Hz to 10 kHz.
2 to 50 VPEAK-PEAK from 10 kHz to 50 kHz.
Auxiliary input
• Current range input : ±50 mAPEAK-PEAK (AC + DC measurement range)
• Voltage range input : ±50 VPEAK-PEAK
DC input
• Voltage measurement range : 0 to +20 VDC or 0 to −20 VDC.