modules monitor and protect rotating machinery
as part of a VM600Mk2 rack-based monitoring
system.
The MPC4Mk2 module is always used with an
associated IOC4Mk2 module as a set of modules.
Both the MPC4Mk2 and the IOC4Mk2 are singlewidth module that occupy a single VM600Mk2
rack slot (module position). The MPC4Mk2 is
installed in the front of a VM600Mk2 rack and the
associated IOC4Mk2 is installed in the rear of the
rack, in the slot directly behind the MPC4Mk2.
Each module connects directly to the rack’s
backplane using two connectors.
Note: The MPC4Mk2 + IOC4Mk2 modules are
compatible with all VM600Mk2 racks (ABE04x
system racks and ABE056 slimline racks) and later
VM600 racks.
System communications
In a VM600Mk2 system (one or more
MPC4Mk2 + IOC4Mk2 modules and any associated
RLC16Mk2 modules), the main communications
interface is the LAN (Ethernet) connector on the
front panel of each MPC4Mk2 module, which is
used for used for communication with the
VibroSight® software running on an external
computer.
In a VM600Mk2 rack (ABE4x), the VME bus can be
used to share information between modules in
the rack. For example, an MPC4Mk2 + IOC4Mk2
module can provide information such as
measurement, alarm and/or status data to a set
of CPUMk2 + IOCMk2 modules which can then
share the information via one of its industry
standard fieldbuses.
In a VM600Mk2 system (one or more
MPC4Mk2 + IOC4Mk2 modules and any associated
MPC4Mk2 modules), the RLC16Mk2 modules are
controlled and operated by a MPC4Mk2, as
determined by the configuration. The VM600Mk2
rack’s Open collector (OC) bus and Raw bus are
used to exchange control and status information
between the MPC4Mk2 + IOC4Mk2 and RLC16Mk2
modules.
Relays
The MPC4Mk2 + IOC4Mk2 machinery protection
modules include five relays. The four userconfigurable relays (RL1 to RL4) can be used by a
VM600Mk2 system to remotely indicate system
alarm and/or status information. While, a
common circuit-fault relay (FAULT) is used to
indicate a problem with the MPC4Mk2 + IOC4Mk2
modules as detected by the internal diagnostics
(BIST).
The relays in a VM600Mk2 system (specifically one
or more sets of MPC4Mk2 + IOC4Mk2 modules and
any associated RLC16Mk2 modules), are driven by
control circuitry that supports a VM600Mk2 system
safety-line, that is, a system-wide control signal
that automatically drives all system relays
(IOC4Mk2 and RLC16Mk2) and analog outputs
(IOC4Mk2) to a safe state should a problem be
detected. In this way, IOC4Mk2 and RLC16Mk2
relays configured as normally energised (NE) can
always be de-energised in the event of a problem
with one of the components of the relay coil
control signal.
Note: This supports the “de-energise to trip
principle” required in safety-related applications.
Software
MPC4Mk2 + IOC4Mk2 modules, as part of a
VM600Mk2 system), are software configured using
the VibroSight® software.
To meet stringent cybersecurity and API 670
requirements, MPC4Mk2 + IOC4Mk2 modules
segregate machinery protection (MPS) and
condition monitoring (CMS) by using separate
configurations and different VibroSight
configuration software:
• VibroSight Protect supports the configuration
and operation of the machinery protection (MPS)
functionality for a VM600Mk2 system.
• VibroSight Capture supports the configuration
and operation of the condition monitoring (CMS)
functionality for a VM600Mk2 system.
• Other VibroSight software modules support
operations such as data display and analysis
(VibroSight Vision), data logging and postprocessing (VibroSight Server) system
maintenance (VibroSight System Manager), etc.
DESCRIPTION (continued)
More generally for extended condition monitoring
system (CMS) applications, the VibroSight
software supports the configuration and
operation of XMx16/XIO16T modules for condition
monitoring and/or combustion monitoring,
including the processing and presentation of
measurement data for analysis. VibroSight is also
used to configure and manage CPUMk2 + IOCMk2
modules.
Note: The VibroSight® software is also from the
vibro-meter® product line.
Applications information
As part of a VM600Mk2 system,
MPC4Mk2 + IOC4Mk2 machinery protection
modules are ideal for the monitoring and
protection of critical assets such as gas, steam or
hydro turbines and other high-value rotating
machines in a wide range of industrial
applications.
For further information, contact your local
Meggitt representative
Supported sensors
Currently available : Compatible with a wide range of sensors and measurement chains
with current (2-wire) or voltage (3-wire) outputs, including the
following sensors from the Meggitt vibro-meter® product line:
• CAxxx vibration sensors (piezoelectric accelerometers)
• CExxx and PVxxx vibration sensors (piezoelectric accelerometers