DCS; Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

GEGenerator Protection System Generator Protection, Control and Asset Management

From:GE | Author:LIAO | Time :2025-08-14 | 303 Browse: | Share:

Overview

The relay features generator unbalance, generator differential, over excitation, loss of 

excitation, 3rd harmonic neutral undervoltage, over and under frequency, synchrocheck 

and other essential functions with a basic order option. Additionally available with an 

advanced order option are overall differential (to protect the transformer-generator 

combined), directional overcurrent elements, restricted ground fault, 100% stator ground, 

out-of-step protection, rate of change of frequency, power factor, harmonic detection, 

frequency out-of-band accumulation and others. An optional RTD module allows for 

thermal protection and monitoring. An optional analog inputs/outputs module allows for 

monitoring of generator excitation current, vibration and other parameters.

These relays contain many innovative features. To meet diverse utility standards and 

industry requirements, these features have the flexibility to be programmed to meet 

specific user needs. This flexibility will naturally make a piece of equipment difficult to 

learn. To aid new users in getting basic protection operating quickly, setpoints are set to 

typical default values and advanced features are disabled. These settings can be 

reprogrammed at any time.

Programming can be accomplished with the front panel keys and display. Due to the 

numerous settings, this manual method can be somewhat laborious. To simplify 

programming and provide a more intuitive interface, setpoints can be entered with a PC 

running the EnerVista 8 Setup software provided with the relay. Even with minimal 

computer knowledge, this menu-driven software provides easy access to all front panel 

functions. Actual values and setpoints can be displayed, altered, stored, and printed. If 

settings are stored in a setpoint file, they can be downloaded at any time to the front panel 

program port of the relay via a computer cable connected to the USB port of any personal 

computer.

A summary of the available functions and a single-line diagram of protection and control 

features is shown below. For a complete understanding of each feature operation, refer to 

the About Setpoints chapter, and to the detailed feature descriptions in the chapters that 

follow. The logic diagrams include a reference to every setpoint related to a feature and 

show all logic signals passed between individual features. Information related to the 

selection of settings for each setpoint is also provided.

Description of the 889 Generator Protection System

CPU

Relay functions are controlled by two processors: a Freescale MPC5125 32-bit 

microprocessor that measures all analog signals and digital inputs and controls all output 

relays, and a Freescale MPC8358 32-bit microprocessor that controls all the advanced 

Ethernet communication protocols.

Analog Input and Waveform Capture

Magnetic transformers are used to scale-down the incoming analog signals from the 

source instrument transformers. The analog signals are then passed through a 11.5 kHz 

low pass analog anti-aliasing filter. All signals are then simultaneously captured by sample 

and hold buffers to ensure there are no phase shifts. The signals are converted to digital 

values by a 16-bit A/D converter before finally being passed on to the CPU for analysis.

The 'raw' samples are scaled in software, then placed into the waveform capture buffer, 

thus emulating a digital fault recorder. The waveforms can be retrieved from the relay via 

the EnerVista 8 Series Setup software for display and diagnostics.

Frequency

Frequency measurement is accomplished by measuring the time between zero crossings 

of the composite signal of three-phase bus voltages, line voltage or three-phase currents. 

The signals are passed through a low pass filter to prevent false zero crossings. Frequency 

tracking utilizes the measured frequency to set the sampling rate for current and voltage 

which results in better accuracy for the Discrete Fourier Transform (DFT) algorithm for offnominal frequencies.

The main frequency tracking source uses three-phase bus voltages. The frequency 

tracking is switched automatically by an algorithm to the alternative reference source, i.e., 

three-phase currents signal if the frequency detected from the three-phase voltage inputs 

is declared invalid. The switching will not be performed if the frequency from the 

alternative reference signal is detected invalid. Upon detecting valid frequency on the 

main source, the tracking will be switched back to the main source. If a stable frequency 

signal is not available from all sources, then the tracking frequency defaults to the nominal 

system frequency.

Phasors, Transients, and Harmonics

All waveforms are processed eight times every cycle through a DC decaying removal filter 

and a Discrete Fourier Transform (DFT). The resulting phasors have fault current transients 

and all harmonics removed. This results in an overcurrent relay that is extremely secure 

  • D20MIC10BASE-T 820-0756 Network card
  • WES13-3 5167-0001-0210 CPU/Auxiliary Control board
  • WES13-3 2508-21001 Embedded digital module
  • D20ME 526-2005-216943 control module
  • D20EME 0526-21170-1 Enhanced Master Communications Module for D20 Substation RTUs
  • 2400-21004 / 2010-3101-0442 – Redundant Power Supply Module for Mark VIe Turbine Control
  • PACSystems™ IC695CPE400 RX3i 64 MB
  • DS200DCFBG2BNC DC2000 DC Feedback Board
  • OLDI Ethernet interface module 56SAM-844
  • IS200BPPBH2CAA Mark VIe Power Supply Module
  • IS210MACCH2AEG Motor Control and Communication Module
  • IS210MACCH2AGG Mark VIe Speedtronic Turbine Control Module
  • IS200AEPAH1AFD Printed circuit board
  • IS200AEPAH1ACB Analog I/O Module
  • IS200WREAS1ADB AERO TRIP TB DBRD sub-board
  • IS200WETAH1AEC large board component made Mark VI system
  • IS200AEPAH1AHD A High-Precision Excitation Control Board for Turbine Systems
  • IS200WEMAH1AEA Control board
  • IS210MACCH1AGG processor card
  • IS230TNRLH1B Discrete Output Modular Assembly
  • Mark V Series DS200PCCAG1ACB PCB Power Connect Card
  • DS200SI0CG1AEA Instantaneous overcurrent card
  • DS200SHVMG1AGE Analog I/O board
  • DS200SI0CG1A6A Input/Output Module
  • DS200SHVMG1AFE SCR High Voltage Interface Board
  • DS200RT8AG3AHC Relay Output Terminal Board
  • DS200FSAAG1ABA PCB Field Supply Gate Amplifier Board
  • 531X307LTBAFG1 F31X307LTBA LAN I/O Terminal Board
  • ABB AFS670 19" Ruggedized Switch AFS670-EREEDDDSSEEEEEEEPZYX05.1.0
  • NI Controller for VXI VXIPC-871B
  • IS200EPMCH1GE Mark VIe Patch Cord Power Distribution Card
  • VMICPCI-7632-03310 IS215UCCAH3A 350-657362-003310J GE gas turbine system control processor board
  • WEA13-13 2508-21001 Control Module / I/O Board
  • WES5120 2340-21004 Controller Main Module
  • WES5120 2340-21006 Field Controller Master Unit Module
  • ​ WESDAC D20ME 18-MAR-13 Excitation Control Module
  • D20 EME 2400-21004 Ethernet communication and expansion module
  • GE DS3800XTFP1E1C Thyristor Fan Out Board Brand
  • GE SR745-W2-P1-G1-HI-A-L-R-E Feeder protection relay
  • GE IS230TNDSH2A Discrete Output Relay Module Brand
  • GE Fanuc IS200TDBSH2ACC Mark VI Terminal Board Brand
  • GE PMC-0247RC-282000 350-93750247-282000F Disk Drive
  • GE PMC-0247RC-282000 350-93750247-282000F Disk Drive
  • GE VMIVME-1150 Serial Communications Controller
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE VMIC Isolated Digital Output VMIVME-2170A
  • GE MULTILIN 760 FEEDER MANAGEMENT RELAY 760-P5-G5-S5-HI-A20-R-E
  • GE IS200AEPAH1BKE IS215WEPAH2BB Printed circuit board
  • GE IS210BPPCH1A Mark VIe I/O Pack Processor Card
  • GE IS220PRTDH1A 336A4940CSP6 High-Performance RTD Input Module
  • GE IS220PDIAH1BE 336A5026ADP4 Discrete Input Module
  • GE IS420ESWBH3A IONET Switch Module
  • GE 516TX 336A4940DNP516TX 16-port Ethernet switch
  • GE EVMECNTM13 Embedded control module
  • GE EVPBDP0001 EVPBDP032 control module
  • GE Hydran M2-X Enhanced Monitoring with Extended Sensor Life
  • GE UR6CH Digital I/O Module
  • GE IC695CPU315-CD Central processing unit
  • GE 531X305NTBAMG1 DR Terminal Board
  • GE 531X305NTBALG1 NTB/3TB Terminal Board 531X Series
  • GE 531X305NTBAJG1 NTB/3TB Terminal Board.
  • GE 531X305NTBAHG1 NTB/3TB Terminal Board 531X
  • GE 531X305NTBAEG1 is a PCB that functions as a DR terminal board.
  • General Electric 531X305NTBACG1 NTB/3TB Terminal Board 531X
  • GE Digital Energy D20 Analog Input Module
  • GE 94-164136-001 main board Control board
  • GE 269 PLUS-D/O-100P-125V Digital motor relay
  • GALIL DMC-9940 High-performance motion controller
  • FUJI NP1BS-08 base plate
  • FUJI NP1Y32T09P1 Transistor drain type digital output module
  • FUJI NP1Y16R-08 Digital Output Module
  • FUJI NP1X3206-A High-speed digital input module
  • FUJI NP1AYH4I-MR current output module
  • FUJI NP1S-22 Power module redundancy
  • FUJI RPXD2150-1T servo drive module
  • FUJI FVR008E7S-2UX Ac frequency converter
  • FUJI Ac frequency converter FVR008E7S-2
  • FUJI FVR004G5B-2 Small general-purpose frequency converter
  • FUJI A50L-2001-0232 Industrial control module
  • FUJI A50L-001-0266#N High-performance servo amplifier
  • Honeywell FS7-2173-2RP Gas sensor
  • Honeywell 10106/2/1 Digital Input Module in Stock
  • FRCE SYS68K CPU-40 B/16 PLC core processor module
  • Foxboro FBM I/O cards PBCO-D8-009
  • Foxboro AD916AE Digital Control System (DCS) Module
  • GE SR750-P5-G5-S5-HI-A20-R-E Multilin Relay
  • FOXBORO H90 H90C9AA0117S Industrial Computer Workstation
  • FOXBORO RH928AW | I/A Series Relay Output Module
  • Foxboro N-2AX+DIO Multi-functional input/output module
  • Foxboro RH924WA FCP280 Fiber Optic Network Adapter
  • FOXBORO H92 Versatile Hardware Component In
  • Foxboro FBM218 P0922VW HART® Communication Redundant Output Interface Module
  • Foxboro E69F-TI2-J-R-S E69F Series Current-To-Pneumatic Signal Converter
  • Foxboro E69F-BI2-S Converter
  • Foxboro H92A049E0700 The host of the DCS control station
  • Foxboro H90C9AA0117S Industrial computer workstation
  • Foxboro RH101AA High-performance industrial control module
  • Foxboro P0922YU FPS400-24 I/A Series Power supply
  • FOXBORO P0973LN Chassis-based managed switch with independent power supply
  • FOXBORO P0926PA Input/output module
  • Fanuc A06B-6050-H402 3 AXIS ANALOG AC SERVO DRIVE
  • FOXBORO L0130AD L0130AE-0H Power module group
  • FOXBORO 0399085B 0303440C+0303458A Combination Control Module
  • FOXBORO SY-0399095E (SY-0303451D+SY-0303460E) Process control board
  • FOXBORO 0399071D 0303440C+0303443B Input/Output (I/O) Module
  • FOXBORO RH924UQ Redundant Controller module
  • FFOXBORO E69F-TI2-S current pneumatic converter
  • FOXBORO FBM219 RH916RH Discrete I/O Module
  • FOXBORO FBM227 P0927AC Module
  • FOXBORO 0399144 SY-0301059F SY-1025115C/SY-1025120E I/O module
  • FOXBORO SY-60399001R SY-60301001RB Industrial Control Module
  • FOXBORO 0399143 SY-0301060R SY-1025115C SY-1025120E Combined control board
  • FOXBORO 873EC-JIPFGZ electrodeless conductivity analyzer
  • FOXBORO P0916PH (High-density HART I/O Module)
  • FOXBORO 870ITEC-AYFNZ-7 Intelligent Electrochemical Transmitters
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • FOXBORO P0916WG Terminal cable
  • FOXBORO P0926MX 2-Port Splitter
  • FOXBORO AD908JQ High-Frequency Module
  • FOXBORO AD916CC Processor module
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • Foxboro p0903nu 1×8 unit sub-component module
  • Foxboro P0911SM Industrial control module
  • Foxboro CM902WM I/O module
  • Foxboro CM902WL Power module