Measurement made easy
Engineered solutions for all applications
Base accuracy
• from 0.06 % of calibrated span (optional 0.04 %)
Reliable sensing system coupled with very latest digital technologies
• provides large turn down ratio up to 100:1
Comprehensive sensor choice
• optimize in-use total performance and stability
10–year stability
• 0.15 % of URL
Flexible configuration facilities
• provided locally via local LCD keypad
TTG (Through-The-Glass) keypad technology
• allows quick and easy local configuration without opening the cover,
even in explosion proof environments
IEC 61508 certification
• version for SIL2 (1oo1) and SIL3 (1oo2) applications
PED compliance
• Category III for PS > 20 MPa, 200 bar
• Sound Engineering Practice (SEP) for PS ≤ 20 MPa, 200 bar
WirelessHART version
• the battery powered solution compliant to IEC 62591
Best-in-class battery life
• up to 10 years @ 32 s update time
• in-field replaceable
Product in compliance with Directive 2011/65/UE (RoHS II)
In-built advanced diagnostics
Specification – functional
Range and span limits
Sensor
code
Upper range limit
(URL)
Lower range limit
(LRL)
Minimum
measuring span
A 1 kPa
10 mbar
4 inH2O
–1 kPa
–10 mbar
–4 inH2O
0.05 kPa
0.5 mbar
0.2 inH2O
B 4 kPa
40 mbar
16 inH2O
–4 kPa
–40 mbar
–16 inH2O
0.2 kPa
2 mbar
0.8 inH2O
E 16 kPa
160 mbar
64 inH2O
–16 kPa
–160 mbar
–64 inH2O
0.54 kPa
5.4 mbar
2.16 inH2O
F 40 kPa
400 mbar
160 inH2O
–40 kPa
–400 mbar
–160 inH2O
0.4 kPa
4 mbar
1.6 inH2O
H* 160 kPa
1600 mbar
642 inH2O
–160 kPa
–1600 mbar
–642 inH2O
1.6 kPa
16 mbar
6.4 inH2O
M* 600 kPa
6 bar
87 psi
–600 kPa
–6 bar
–87 psi
6 kPa
0.06 bar
0.87 psi
P* 2400 kPa
24 bar
348 psi
–2400 kPa
–24 bar
–348 psi
24 kPa
0.24 bar
3.5 psi
Q* 8000 kPa
80 bar
1160 psi
–8000 kPa
–80 bar
–1160 psi
80 kPa
0.8 bar
11.6 psi
S* 16000 kPa
160 bar
2320 psi
–16000 kPa
–160 bar
–2320 psi
160 kPa
1.6 bar
23.2 psi
* For 266DSH gauge version the LRL for sensors H, M, P, Q, S is 1 kPa abs /
10 mbar abs / 0.15 psia
Span limit
Maximum span = URL
(can be further adjusted up to ± URL (TD = 0.5) for
differential models, within the range limits)
IT IS RECOMMENDED TO SELECT THE TRANSMITTER
SENSOR CODE PROVIDING THE TURNDOWN VALUE AS
LOWEST AS POSSIBLE TO OPTIMIZE PERFORMANCE
CHARACTERISTICS.
Zero suppression and elevation
Zero and span can be adjusted to any value within the
range limits detailed in the table as long as:
– calibrated span ≥ minimum span
Damping (feature not available for WirelessHART version)
Selectable time constant : between 0 and 60 s
This is in addition to sensor response time.
Turn on time
Operation within specification in less than 10 s with
minimum damping.
Insulation resistance
> 100 MΩ at 500 V DC (terminals to earth)
Specification – operative limits
Pressure limits
Overpressure limits
The differential pressure transmitters, models 266DSH,
work without damage within the following pressure limits:
Sensors Fill fluid Overpressure limits
Sensor F to S Silicone oil 0.07 kPa abs, 0.7 mbar abs, 0.5 mmHg
and 21 MPa, 210 bar, 3045 psi *, **
Sensor E Silicone oil 0.07 kPa abs, 0.7 mbar abs, 0.5 mmHg
and 16 MPa, 160 bar, 2320 psi *
Sensor B Silicone oil 0.07 kPa abs, 0.7 mbar abs, 0.5 mmHg
and 7 MPa, 70 bar, 1015 psi *
Sensor A Silicone oil 0.07 kPa abs, 0.7 mbar abs, 0.5 mmHg
and 2 MPa, 20 bar, 290 psi *
Sensor F to S Inert
(Galden)
0.135 kPa abs, 1.35 mbar abs, 1 mmHg
and 21 MPa, 210 bar, 3045 psi *, **
Sensor E Inert
(Galden)
0.135 kPa abs, 1.35 mbar abs, 1 mmHg
and 16 MPa, 160 bar, 2320 psi *
* 1 MPa, 10 bar, 145 psi for Kynar-PVDF
** 16 MPa, 160 bar, 2320 psi for AISI 316 ss NACE “exposed bolting“
For flange mounted version
Flange Fill fluid Overpressure limits
ASME B16.5
Class 150
Silicone oil 0.07 kPa abs, 0.7 mbar abs, 0.5 mmHg
and 230 psi
ASME B16.5
Class 300
Silicone oil 0.07 kPa abs, 0.7 mbar abs, 0.5 mmHg
and 600 psi
EN 1092-1 PN 16 Silicone oil 0.07 kPa abs, 0.7 mbar abs, 0.5 mmHg
and 13.5 bar
EN 1092-1 PN 40 Silicone oil 0.07 kPa abs, 0.7 mbar abs, 0.5 mmHg
and 33.8 bar
ASME B16.5
Class 150
Inert
(Galden)
0.135 kPa abs, 1.35 mbar abs, 1 mmHg
and 230 psi
ASME B16.5
Class 300
Inert
(Galden)
0.135 kPa abs, 1.35 mbar abs, 1 mmHg
and 600 psi
EN 1092-1 PN 16 Inert
(Galden)
0.135 kPa abs, 1.35 mbar abs, 1 mmHg
and 13.5 bar
EN 1092-1 PN 40 Inert
(Galden)
0.135 kPa abs, 1.35 mbar abs, 1 mmHg
and 33.8 bar
Static pressure limits
The differential pressure transmitters, models 266DSH
work within specifications between the following limits:
Sensors Static pressure limits
Sensor F to S 1.3 kPa abs, 13 mbar abs, 0.2 psia
and 21 MPa, 210 bar, 3045 psi *, **
Sensor E 1.3 kPa abs, 13 mbar abs, 0.2 psia
and 16 MPa, 160 bar, 2320 psi *
Sensor B 1.3 kPa abs, 13 mbar abs, 0.2 psia
and 7 MPa, 70 bar, 1015 psi *
Sensor A 1.3 kPa abs, 13 mbar abs, 0.2 psia
and 2 MPa, 20 bar, 290 psi *
* 1 MPa, 10 bar, 145 psi for Kynar-PVDF
** 16 MPa, 160 bar, 2320 psi for AISI 316 ss NACE “exposed bolting“
Flange Static pressure limits
ASME B16.5 Class 150 1.3 kPa abs, 13 mbar abs, 0.2 psia and 230 psi
ASME B16.5 Class 300 1.3 kPa abs, 13 mbar abs, 0.2 psia and 600 psi