DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

johnsoncontrolsNAE55 Catalog Page

From:johnsoncontrols | Author:LIAO | Time :2025-08-20 | 1082 Browse: | 🔊 Click to read aloud ❚❚ | Share:

configuration software

Use the password-protected software to enable,

configure, commission, archive data, monitor,

command, and perform system diagnosis from any

device through a web browser, without the need for

separate workstation software.

Linux® operating system

The NAE55 network engines at Release 10.0 and

later run on Linux, which is a robust, widelyaccepted, and readily-supported operating system.

Background file transfer

With this new feature, you can transfer firmware

upgrades, archive databases, HTTPS security

certificates, and security databases from the

System Configuration Tool (SCT) to the NAE55

while the engine remains operational, minimizing

system disruptions. Background file transfer is

only available for NAE55s at Release 10.1 or later,

and for the new family of SNE and SNC network

engines that were introduced at Release 10.1. For

information about the newest engines, refer to the

SNE/SNC Product Bulletin (LIT-12013296)

Ordering information

Contact the nearest Johnson Controls representative to order a network engine. The following tables list the

product code numbers and accessories for all available network engines based on model. If you receive an

NAE55 engine from the factory that is imaged with an older release, you can field-upgrade the engine to

Release 12.0 if the upgrade is supported. To order repair parts, add -702 or -703 in place of the last number

(for example, MS-NAE5521-703).

Table 1: NAE5510-2U ordering information (Release 8.1 only)

Product code number Release Description

MS-NAE55xx-x. Base

features of each NAE55

N/A NAE55 Network Automation Engines: Requires a 24 VAC power supply.

Each model includes two RS-232-C serial ports, two USB serial ports,

two RS-485 ports, one Ethernet port, and one MS-BAT1010-0 Data

Protection Battery. Supports a BACnet IP network.

MS-NAE5510-2U

Note: You cannot purchase a MSNAE5510-2U as it is

discontinued. However, you can still

upgrade an MSNAE5510-2U to the

Metasys UL 864

Release 8.1.

8.1 Supports two N2 Bus or two BACnet MS/TP, RS-485 trunks or one N2

Bus trunk and one BACnet MS/TP trunk. Supports a maximum of 100

devices on each N2 Bus or BACnet MS/TP trunk.

Note: This model is UL 864 10th Edition UUKL/ORD-C100-13

UUKLC Standard for Smoke Control Equipment for Release 8.1

only. Refer to the Metasys® System UL 864 10th Edition UUKL/

ORD-C100-13 UUKLC Smoke Control System Technical Bulletin

(LIT-12012487) for detailed specifications, requirements, and procedures for installing and operating UUKL 864 Listed Metasys

system devices. For example, in order to be UL/cUL compliant,

this model must be pre-installed and pre-wired in a standard or

custom panel built at the Johnson Controls Reynosa factory.

MS-NAE5510-3U 8.1 Supports two N2 Bus or two BACnet MS/TP (RS-485) trunks or one N2

Bus trunk and one BACnet MS/TP trunk. Supports a maximum of 100

devices on each N2 Bus or BACnet MS/TP trunk.

Note: This model is UL 864 10th Edition UUKL/ORD-C100-13

UUKLC Standard for Smoke Control Equipment for Release 8.1

only. Refer to the Metasys® System UL 864 10th Edition UUKL/

ORD-C100-13 UUKLC Smoke Control System Technical Bulletin

(LIT-12012487) for detailed specifications, requirements, and procedures for installing and operating UUKL 864 Listed Metasys

system devices. For example, in order to be UL/cUL compliant,

this model must be pre-installed and pre-wired in a standard or

custom panel built at the Johnson Controls Reynosa factory.

Table 2: NAE55-3 ordering information (Release 8.1 or 12.0)

Product code number Release Description

MS-NAE55xx-x, base

features of each NAE55

N/A NAE55 Network Automation Engines: Requires a 24 VAC power supply.

Each model includes two RS-232-C serial ports, two USB serial ports,

two RS-485 ports, one Ethernet port, and one MS-BAT1010-0 Data

Protection Battery. Supports a BACnet IP network.

MS-NAE5510-3 12.0 Supports two third-party trunks, Modbus RTU or TCP, M-Bus, or KNX,

and two N2 or two BACnet MS/TP (RS-485) trunks or one N2 trunk and

one BACnet MS/TP trunk. Supports up to 100 devices on each N2 or

BACnet MS/TP trunk. Supports a BACnet/IP or BACnet/SC network.

This model is a BACnet BTL-Listed controller at protocol revision 15

(PR15). Supports BACnet/SC at Release 12.0.

MS-NAE5510-3U 8.1 Supports two N2 Bus or two BACnet MS/TP (RS-485) trunks or one N2

Bus trunk and one BACnet MS/TP trunk.

Note: This model is UL 864 10th Edition UUKL/ORD-C100-13

UUKLC Standard for Smoke Control Equipment for Release 8.1

only. Refer to the Metasys® System UL 864 10th Edition UUKL/

ORD-C100-13 UUKLC Smoke Control System Technical Bulletin

(LIT-12012487) for detailed specifications, requirements, and procedures for the installation and operation of UUKL 864 Listed

Metasys system devices. For example, in order to be UL/cUL compliant, this model must be pre-installed and pre-wired in a standard or custom panel built at the Johnson Controls Reynosa factory.

MS-NAE5520-3 12.0 Supports a LonWorks trunk, two third-party trunks, Modbus RTU or

TCP, M-Bus, or KNX, or two N2 trunks/BACnet MS/TP (RS-485) trunks,

or one N2 trunk and one BACnet MS/TP trunk. Supports up to 255

devices on the LonWorks trunk. Supports up to 100 devices on each N2

or BACnet MS/TP trunk. Supports a BACnet/IP or BACnet/SC network.

  • GE 151X1233DD01SA02 Pitch Battery Charger Assy IS200AEPBH1B
  • GE 151X1233DB02SA02 Rev A IS200AEPBH1B Wind Turbine Converter
  • GE 151X1207CK02SA02 SCR 4400 V 1850 A IS200EDEXG1ADA General Electric EX2100
  • Triconex 3723X 32-Channel TMR Analog Input Module with HART
  • SHINKAWA VM-21G  SIGNAL CONDITIONER SOCKET
  • SHINKAWA VM-21R REVOLUTION SIGNAL CONDITIONER
  • SHINKAWA VM-21T DISPLACEMENT INPUT THRUST SIGNAL CONDITIONER
  • SHINKAWA VM-21D 6-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21P 3-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21A  VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-21K DISPLACEMENT INPUT VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-25S01 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-25 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-772B DEVICE CONFIG
  • SHINKAWA VM-771B MCL VIEW
  • SHINKAWA VM-76B INSTRUMENT RACK
  • SHINKAWA VM-75B POWER SUPPLY MODULE
  • SHINKAWA VM-742B NETWORK COMMUNICATION MODULE
  • SHINKAWA VM-741B LOCAL COMMUNICATION &  PHASE MARKER MODULE
  • SHINKAWA VM-722B 9-CHANNEL RELAY MODULE
  • SHINKAWA VM-707B AERODERIVATIVE GAS TURBINE  MONITOR MODULE
  • SHINKAWA VM-706B ROD DROP MONITOR MODULE
  • SHINKAWA VM-705B 18-CHANNEL TEMPERATURE   MONITOR MODULE
  • SHINKAWA VM-704B TEMPERATURE MONITOR MODULE
  • SHINKAWA VM-702B ABSOLUTE VIBRATION  MONITOR MODULE
  • SHINKAWA VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE
  • SHINKAWA MODEL VM-5X INTERFACE UNIT
  • SHINKAWA MODEL VM-5W2 DUAL POWER SUPPLY INSTRUMENT RACK
  • SHINKAWA MODEL VM-5H4  INSTRUMENT RACK (for VM-5Z5.6.7)
  • SHINKAWA MODEL VM-5G  SINGLE UNIT   INSTRUMENT RACK
  • SHINKAWA MODEL VM-5Z5,6,7  POWER SUPPLY UNIT
  • SHINKAWA MODEL VM-5Y1,2,3 RELAY MODULE UNIT
  • SHINKAWA MODEL VM-5P3 PHASE MARKER UNIT
  • SHINKAWA MODEL VM-53 DUAL COMMUNICATION UNIT
  • SHINKAWA MODEL VM-52 BOTTOM HOLD MONITOR
  • SHINKAWA MODEL VM-51 ROD DROP MONITOR
  • SHINKAWA MODEL VM-5R TACHOMETER
  • SHINKAWA MODEL VM-5S DUAL TACHOMETER
  • SHINKAWA MODEL VM-5A DUAL VALVE
  • SHINKAWA MODEL VM-5E DUAL CASE
  • SHINKAWA MODEL VM-5L COMPLEMENTARY INPUT
  • SHINKAWA MODEL VM-5N RAMP DIFFERENTIAL
  • SHINKAWA MODEL VM-5D DUAL DIFFERENTIAL
  • SHINKAWA MODEL VM-5T DUAL THRUST MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5M DUAL PATH MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5U DUAL SEISMIC MONITOR
  • SHINKAWA MODEL VM-55 VIBRATION MONITOR
  • SHINKAWA VM-742B1-5 VIBRATION MONITORING SYSTEM CARD
  • Shinkawa PSP-17B P-24-64A P-24-64B Circuit Board Module
  • SHINKAWA MGP-67 PCB
  • Shinkawa JBP-278 P-22-48A-1 P-22-48B-1 Circuit Board Module
  • Shinkawa VM-721B 18-CHANNEL RELAY MODULE
  • Shinkawa FRP-337 P-26-54A P-26-54B Circuit Board Module
  • Shinkawa CPP-111 P-25-59A P-25-59B Circuit Board Module
  • Shinkawa WKN-142K2-2 Vibration Transmitter
  • SHINKAWA VL-202A08L-1012 Rotor Position Monitor Probe Sensor
  • Shinkawa CPP-128 P-26-74A P-26-74B Circuit Board Module
  • Honeywell 51402755-100 PROCESSOR CARD
  • Honeywell 51107595-100 Power
  • HONEYWELL 51304544-100 Control Board
  • HONEYWELL 51109919-100 BOARD
  • HHoneywell 51204160-175 Digital Input Module
  • Honeywell 51304754-150 High Level Analog Input Module
  • HONEYWELL 51304690-100 DIGITAL INPUT CARD
  • Honeywell 51401635-150  COMM CONTROL
  • HONEYWELL 51204174-175 MC-TAOY 52 ANALOG OUTPUT BOARD
  • HONEYWELL  51400596-100
  • HONEYWELL 51401291-100 board card
  • HONEYWELL 51401642-150 I/O LINK MODULE
  • Honeywell LCN‑E Hub Power Supply 38500148‑300
  • Honeywell LCN‑E Hub redundant 38500143‑202 Twisted‑pair LCN
  • Honeywell LCN‑E Hub non‑redundant,38500143‑102
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAC01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAB01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MT11‑520
  • Honeywell STI‑CE Smart Transmitter Interface 51304516‑150
  • Honeywell STI Smart Transmitter Interface 51304516‑100 MC‑PSTX02
  • Honeywell ulse Counter IOP,51304386‑100.MU‑PPIX02
  • Honeywell DO Digital Output IOP‑CE 51304487‑150 CE  version
  • Honeywell DO Digital Output IOP  51304487‑100 MC‑PDOX02
  • Honeywell TDC‑3000 SOE DI IOP,51402625-175 MC‑PDIS12
  • Honeywell TDC‑3000  DI Digital Input IOP‑CE 51304485‑150
  • Honeywell TDC‑3000 DI Digital Input IOP 51304485‑100 MC‑PDIX02
  • Honeywell TDC‑3000 AO Analog Output IOP 51304757‑100 MU‑PAOX02
  • Honeywell TDC‑3000  TC Thermocouple IOP 51304756‑100 MU‑TAMT03
  • Honeywell TDC‑3000   51304755‑100 MU‑TAMR03
  • Honeywell TDC‑3000 LLAI Multiplex AI IOP,51304362‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP‑CE,51304363‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP,51304363‑100.4‑20mA
  • Honeywell TDC‑3000  HPM Power Supply,51401731‑100
  • Honeywell TDC‑3000 Standard 1986.HPM High‑Performance PM CPU,51402362‑100
  • Honeywell TDC‑3000 APM Advanced Process Manager CPU,51304459‑100
  • Honeywell TDC‑3000 Standard 1986.PM Process Manager CPU,51304362‑100
  • Honeywell TDC‑3000 NIM Network Interface Module,51304481‑200
  • Honeywell TDC‑3000 NIM Network Interface Module 51304481‑100
  • Honeywell TDC‑3000 BASIC,LCN Terminator Resistor,30732052‑001.Coaxial
  • Honeywell TDC‑3000 BASIC,Hiway Coupler,30753732-001
  • Honeywell TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309
  • Honeywell TDC‑3000 BASIC,HLPIU High‑Level PIU,4DP7APCFA106
  • Honeywell TDC‑3000 BASIC,Multifunction Controller(TDC‑2000 DHW),4DP7MFA103
  • Honeywell TDC‑3000 BASIC,Extended Controller(TDC‑2000 DHW),4DP7AXA102
  • Honeywell TDC‑3000 BASIC,Basic Controller(TDC‑2000 DHW),4DP7BBA101
  • Honeywell TDC‑3000 BASIC,XLCNE2 LCN Extender,51305508‑100.Coaxial LCN
  • Honeywell TDC‑3000 BASIC,E‑PLCG PLC Gateway,51400997‑200
  • Honeywell TDC‑3000 BASIC,PLNM Plant Network Module,51401163‑100
  • Honeywell TDC‑3000 BASIC,CG Computer Gateway,80360206‑001
  • Honeywell TDC‑3000 BASIC,HG High‑Speed Gateway,51304526‑100
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑200
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑100
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑800.K2LCN‑8
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑600.K2LCN‑6
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑400,K2LCN‑4
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑300.K2LCN‑3
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑200,K2LCN‑2
  • Honeywell TDC‑3000 BASIC,US Universal Station CPU,51401288‑200
  • TDC‑3000 BASIC,US Universal Station CPU,51401288‑100
  • SHINKAWA VM-21P1 Signal Conditioner 0-50MM 24VDC
  • Shinkawa RiverNew Vibration Transducer VK202 Series
  • Shinkawa Electric VM-3E2 Vibration Monitor Module
  • Shinkawa JBP-47 P-22-48A-1 / P-22-48B-1 Circuit Board Module
  • Shinkawa MODEL VM-5K DUAL VIBRATION MONITOR
  • Shinkawa CMU-15A (CMU15A) Industrial Camera Controller
  • Shinkawa CMU-13A CMU13A Industrial Camera Controller
  • Shinkawa EFU-10 (EFU10) Spark Generator Unit
  • Shinkawa UTC-1000 ZUP-02C Board
  • Shinkawa MDP-89 MDP89 P-24-674A P-24-674B Circuit Board Module