A-BEasyLine Continuous Gas Analyzers Models EL3020, EL3040 Software Version 3.3

From:A-B | Author:LIAO | Time :2025-08-13 | 757 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Basic Steps 

The following basic steps should be followed for the installation and 

commissioning of the gas analyzer: 

1 Please note the information on the intended application (see page 9). 

2 Follow safety precautions (see page 10). 

3 Prepare for the installation, provide the requisite material (see 

page 14). 

4 Unpacking the gas analyzer (see page 41). 

5 Check sample gas path seal integrity (see page 119). 

6 Install the gas analyzer (see page 66). 

7 Connect the gas lines (see page 67). 

8 Connect the electrical leads (see page 79). 

9 Check the installation (see page 90). 

10 Purge the sample gas path (see page 91). 

11 Start up the gas analyzer (see page 92). 

12 Configure the gas analyzer.

Intended Application 

Intended Application of the Gas Analyzer 

The gas analyzer is designed for continuous measurement of the 

concentration of individual components in gases or vapors. 

Any other use is not as specified. 

The specified use also includes taking note of this operator's manual. 

The gas analyzer may not be used for the measurement of ignitable 

gas/air or gas/oxygen mixtures. 

The gas analyzer version with stainless steel gas lines and gas 

connections (EL3020 and EL3040 models) may be used for the 

measurement of flammable gases1

 and vapors in a non-hazardous 

environment, The special requirements for the measurement of 

flammable gases (see page 39) must be complied with. The oxygen 

sensor and the modules of the integrated gas feed (Option "Integrated 

Gas Feed" – only in the EL3020 model, not with Limas23, ZO23, 

Fidas24) may not be used for the measurement of flammable gases. 

The explosion-proof version of the gas analyzer with degree of protection 

II 3G (see page 40) (EL3040 model) may be used for the measurement 

of non-flammable gases and vapors in a hazardous environment. 

NOTE 

The version for the measurement of flammable gases and vapors and the 

explosion-proof version with degree of protection II 3G are different 

versions of the gas analyzer and designed for different applications. 

Safety Information 

Requirements for Safe Operation 

In order to operate in a safe and efficient manner the device should be 

properly handled and stored, correctly installed and set-up, properly 

operated and correctly maintained. 

Personnel Qualifications 

Only persons familiar with the installation, set-up, operation and 

maintenance of comparable devices and certified as being capable of 

such work should work on the device. 

Special Information and Precautions 

These include 

 The content of this operator's manual, 

 The safety information affixed to the device, 

 The applicable safety precautions for installing and operating 

electrical devices, 

 Safety precautions for working with gases, acids, condensates, etc. 

National Regulations 

The regulations, standards and guidelines cited in this operator's manual 

are applicable in the Federal Republic of Germany. The applicable 

national regulations should be followed when the device is used in other 

countries. 

Device Safety and Safe Operation 

The device is designed and tested in accordance with the relevant safety 

standards and has been shipped ready for safe operation. To maintain 

this condition and to assure safe operation, read and follow the safety 

information in this operator's manual. Failure to do so can put persons at 

risk and can lead to device damage as well as damage to other systems 

and devices. 

Protective Lead Connection 

The protective lead (ground) should be attached to the protective lead 

connector before any other connection is made

Risks of a Disconnected Protective Lead 

The device can be hazardous if the protective lead is interrupted inside or 

outside the device or if the protective lead is disconnected. 

Risks Involved in Opening the Covers 

Current-bearing components can be exposed when the covers or parts 

are removed, even if this can be done without tools. Current can be 

present at some connection points. 

Risks Involved in Working with an Open Device 

All work on a device that is open and connected to power should only be 

performed by trained personnel who are familiar with the risks involved. 

When Safe Operation can no Longer be Assured 

If it is apparent that safe operation is no longer possible, the device 

should be taken out of operation and secured against unauthorized use. 

The possibility of safe operation is excluded: 

 If the device is visibly damaged, 

 If the device no longer operates, 

 After prolonged storage under adverse conditions, 

 After severe transport stresses. 

WARNING EXPLOSION HAZARD 

Substitution of components may impair suitability for Class I, Division 2. 

I/O connectors must only be connected to Class 2 circuits

Fidas24: Information on the safe operation of the gas analyzer 

  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 8DIO / 2UAI
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1550 Slice I/O, RS232/485. 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1550 Slice I/O, RS232/485. 8DIO / 2UAI
  • CTI 2500S-23-1550 Slice I/O, RS232/485. 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1050 Slice I/O, Ethernet, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1050 Slice I/O, Ethernet, 8DIO / 2UAI
  • CTI 2500S-23-1050 Slice I/O, Ethernet, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500C-32F-CJC 32-Pin Field Wiring Connector with Cold Junction Compensation
  • CTI 2500C-32F 32-Pin Field Wiring Connector
  • CTI 2500C-8-TC Eight Thermocouple Inputs
  • CTI 2500C-8-RTD Eight RTD Inputs
  • CTI 2500C-8-RL-FC 8 Form-C Relay Outputs
  • CTI 2500C-8-IDO-24V 8 Isolated 24VDC Outputs
  • CTI 2500C-8-IDO-120V 8 Isolated 120VAC Outputs
  • CTI 2500C-16-DO-24V Sixteen 24VDC Digital Outputs
  • CTI 2500C-16-DO-120V Sixteen 120VAC Digital Outputs
  • CTI 500C-16-IDI-24V Sixteen Isolated 24V AC/DC Digital Inputs
  • CTI 2500C-16-IDI-120V Sixteen Isolated 120V AC/DC Digital Inputs
  • CTI 2500C-16-DIDO-SIM Sixteen Digital Input and Output SImulator
  • CTI 2500C-16-DI-24V Sixteen 24V AC/DC Digital Inputs
  • CTI 2500C-16-DI-120V Sixteen 120V AC/DC Digital Inputs
  • CTI 2500C-RBC-RS485 RS485 Remote Base Controller
  • CTI 2500C-RBC-PRF Profibus Remote Base Controller
  • CTI 2500C-PS-24V-35 35-Watt DC Power Supply
  • CTI 2500C-PS-120V-35 35-Watt AC Power Supply
  • CTI 2500C-R8 Eight-Slot Base
  • CTI 2500C-R4 Four-Slot Base
  • CTI 2500C-R16 Sixteen-Slot Base
  • CTI 2500C-2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2500C-J750 Compact Janus PAC with 3MB Project Memory
  • CTI 2500C-C300 CPU with 512K User Memory
  • CTI 2500C-C200 CPU with 256K User Memory
  • CTI 2500C-C100 CPU with 128K User Memory
  • CTI 2500C-8-AO 8 Analog Outputs
  • CTI 2500C-8-AI 8 Analog Inputs
  • CTI 2559-FCAL Precision Calibration Connector
  • CTI 2559-FPC 40-Position Screw-Terminal Connector
  • CTI 2500-RFC PLC to RF Modem Cable
  • CTI 2500-40F 40-Position Standard Screw-Terminal Connector
  • CTI 2505 Vibration Sensor Interface Module
  • CTI 2554-A 4-Channel Isolated High Speed Counter Module
  • CTI 2553-A 2-Channel Mag Meter Input Module
  • CTI 2502 2-Channel High Speed Counter Input Module
  • CTI 2559-TC 8-Channel Thermocouple Input Module
  • CTI 2556-A 16-Channel Isolated Thermocouple Input Module
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2551-A 8-Channel Isolated Thermocouple Input Module
  • CTI 2559-RTD 8-Channel RTD Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2557 16-Channel RTD Input Module
  • CTI 2552-A 8-Channel Isolated RTD Input Module
  • CTI 2534 8-Point Form-C Relay Output Module
  • CTI 2532 16-Point Form-A Relay Output Module
  • CTI  2531 32-Point Form-A Relay Output Module
  • CTI  2530 8-Point Form-C Relay Output Module
  • CTI  2562 8-Channel Analog Output Module
  • CTI  2560-A 8-Channel Isolated Analog Output Module
  • CTI  2501 8in/4out Analog Module
  • CTI  2558 8-Channel Analog Input Module
  • CTI  2555-A 16-Channel Analog Input Module
  • CTI  2550-A 8-Channel Isolated Analog Input Module
  • CTI  2599 8/16/32-Point AC Output Module
  • CTI  2598-8 8-Point AC Output Module
  • CTI   2598 8/16-Point AC Output Module
  • CTI   2597 8/16/32-Point DC Output Module
  • CTI 2596-8 8-Point DC Output Module
  • CTI 2596 8/16-Point DC Output Module
  • CTI 2595 16-Point TTL/Word Output Module
  • CTI 2591-EF 16-Point Isolated 11-146 VDC Output with Front Panel Accessible Fuses
  • CTI 2591-A 16-Point Isolated 11-146 VDC Output Module
  • CTI 2590-EF 16-Point Isolated 20-132 VAC Output with Front Panel Accessible Fuses
  • CTI 2590-A 16-Point Isolated Discrete 20-132 VAC Output Module
  • CTI 2589-B 8/16/32-Point Universal Discrete Input Module
  • CTI 2589-A 8/16/32-Point Universal Discrete Input Module
  • CTI 2588-8 8-Point Universal Discrete Input Module
  • CTI 2585 16-Point TTL/Word Input Module
  • CTI 2582 16-Point Isolated 125 VDC Input Module
  • CTI 2581 16-Point Isolated 12-56 VDC Input Module
  • CTI 2580 16-Point Isolated 95-132 VAC Input Module
  • CTI 2500-TAP RS485 Network Tap
  • CTI 2500-RIO-B RS485 Remote Base Controller
  • CTI 2500-RIO-A RS485 Remote Base Controller
  • CTI 2500-RBC Profibus Remote Base Controller
  • CTI 2515-A 100-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2515 100-Watt AC Power Supply (MATURE - replaced by 2515-A)
  • CTI 2513-A 75-Watt DC Power Supply with Redundancy Support
  • CTI 2513 75-Watt 24VDC Power Supply
  • CTI 2512-A 75-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2512 75-Watt AC/DC Power Supply
  • CTI 2510 125 VDC Power Supply
  • CTI 2500-SSB Single Slot Blank Front Panel
  • CTI 2500-R11-A Eleven-Slot Redundant Base
  • CTI 2500P-R16 Sixteen-Slot Base with High-Speed Channel
  • CTI 2500P-R8 Eight-Slot Base with High-Speed Channel
  • CTI 2500P-R4 Four-Slot Base with High-Speed Channel
  • CTI 2541 Redundant Processor Manager Module
  • CTI 2577 Profibus DP Slave Adapter
  • CTI 2573-MOD Serial Interface Adapter with MODBUS
  • CTI 2572-AF Fast Ethernet TCP/IP Adapter with Optical Fiber Connection
  • CTI 2572-A Fast Ethernet TCP/IP Adapter
  • CTI 2572 Ethernet TCP/IP Adapter
  • CTI 2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2576 DeviceNet™ Scanner Module (MATURE)
  • CTI 2500P-ECC1 Ethernet Communications Coprocessor
  • CTI 2500P-JACP Janus Application Coprocessor
  • CTI 2500P-ACP1 Application Coprocessor (MATURE - replaced by 2500P-JACP)
  • CTI 2500P-J450 Janus PAC with 2MB Project Memory
  • CTI 2500-C400 CPU with 3072K User Memory
  • CTI 2500-C300 CPU with 512K User Memory
  • CTI 2500-C200 CPU with 256K User Memory
  • CTI 2500-C100 CPU with 128K User Memory
  • CTI 2500P-J750 Janus PAC with 3MB Project Memory
  • Shinkawa WHF3006M Displacement Converter
  • Shinkawa JBP-220 (P-24-94A / P-24-94B) Circuit Board Module
  • SHINKAWA   WKN-142K5  2-WIRE VIBRATION TRANSDUCER
  • Shinkawa FRP-321 (P-26-54A / P-26-54B) Circuit Board Module
  • Shinkawa IOP-160 (P-25-72A / P-25-72B) Circuit Board Module
  • Shinkawa PK-147B-1 / PK-147A-1 Circuit Board Module
  • Shinkawa CPP-91A Circuit Board Module
  • Shinkawa FRP-177 PCB Module
  • Shinkawa CPP-127 (P-26-74A / P-26-74B) Circuit Board Module
  • Shinkawa FRP-227 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa MDP-104 (P-25-83A / P-25-83B) Circuit Board Controller
  • Shinkawa VK-143P2 High-precision eddy current sensor driver/signal conditioner
  • Shinkawa FRP-226 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa CPP-107A P-22-99A P-22-99B Circuit Board Module