DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

MTLCertificate Number Baseefa09ATEX0155 Issue 6

From:MTL | Author:LIAO | Time :2025-08-20 | 415 Browse: | 🔊 Click to read aloud ❚❚ | Share:

transformers that provide galvanic isolation between the hazardous and non-hazardous area circuitry, zener diode chains

and resistors providing voltage and current limitation. The above, together with other electronic components are mounted

on a single printed circuit board (PCB) and housed in a moulded plastic enclosure. Polarised plugs and sockets are

provided for hazardous and non-hazardous area connections. LED indication is fitted to indicate power-on.

The MTL454IS Single Channel Repeater Power Supply, 4/20mA for 'Smart' Transmitters is a depopulated version ofthe

MTL4544S and has only one channel populated.

The MTL4544D Repeater Power Supply, 4/20mA for 2 or 3 Wire Transmitters with two outputs is designed to provide a

floating d.c. supplies for energising a 2 or 3-Wire 4/20mA Transmitter located in the hazardous area and repeat the current

on two channels in the non-hazardous area, whilst restricting the transfer of energy from the unspecified non-hazardous

area apparatus to the intrinsically safe circuits by means of limitation of current and voltage. The apparatus also allows bidirectional signal communication between the hazardous and non-hazardous area by the connection of a hand-held

communicator (HHC). The apparatus uses the same printed circuit board and enclosure as the MTL4544S but is populated

with only one hazardous area transmitter connection and two non-hazardous area outputs fitted.

The MTL454IT Single Channel Repeater Power Supply, 4/20mA for 2 or 3-Wire Transmitters is similar to the

MTL454I S but is fitted with different voltage and current limitation components and therefore has different output

parameters.

MTL4541S, MTL4544S & MTL4544D Input / Output Parameters

Non-hazardous Area Terminals 8, 9, 11, 12, 13 & 14

Urn 253V Lm.S.

The apparatus is designed to operate on non-hazardous area terminals 8, 9, 11, 12, 13 & 14 from a d.c. supply voltage of

up to 35V.

Hazardous Area Terminals 2 W.r.t. 1 (Channel 1)

Or

Hazardous Area Terminals 5 W.r.t. 4 (Channel 2 - MTL4544S model)

28V

93mA

O.65W

o

o

Hazardous Area Terminals 3 W.r.t. 1 (Channel 1)

Or

Hazardous Area Terminals 6 w.r.t. 4 (Channel 2 - MTL4544S model)

1.1V

53mA

15mW

UI

I 1

30V

121mA

C1

L1

o

o

Although the apparatus does not comply with the simple apparatus requirements of Clause 5.7 of EN 60079-11: 2012,

when terminals 3 W.r.t. 1 or terminals 6 W.r.t 4 (MTL4544S model only) are connected in an intrinsically safe circuit the

internal stored energy, voltage and current of the interface will not add more than the values specified in Clause 5.7 of

EN 60079-11: 2012 to the parameters ofthe circuit into which it is connected.

When an external intrinsically safe source is connected to these terminals it should have a source resistance of Uj / Ii and

the capacitance and either the inductance or inductance to resistance ratio (L/R) ofthe hazardous area connections must not

exceed the values detailed in the certificate of the intrinsically safe source. Hazardous area terminals 2 and 5 must not be

used when the source is connected.

Hazardous Area Terminals 2 W.r.t. 3 (Channel 1)

Or

Hazardous Area Terminals 5 W.r.t. 6 (Channel 2 - MTL4544S model)

28V

87mA

0.61W

o

o

Each channel must be considered as a separate intrinsically safe circuit.

Load Parameters

The capacitance and either the inductance or inductance to resistance ratio (L/R) of the hazardous area load connected

must not exceed the following values for either channel:

GROUP CAPACITANCE INDUCTANCE OR LIRRATIO

(J1F) (mH) (J1H/ohm)

Hazardous Area Terminals 2 w.r.t. 1 or 5 W.r.t. 4 (MTL4544S only)

IIC 0.083 4.2 56

IIB* 0.65 12.6 210

IIA 2.15 33.6 444

I 3.76 53.7 668

Hazardous Area Terminals 3 W.r.t. 1 or 6 W.r.t 4 (MTL4544S only)

IIC 100 12.8 2,438

IIB* 1,000 47.8 8,932

IIA 1,000 104.7 18,140

I 1,000 156.2 28,229

Hazardous Area Terminals 2 W.r.t. 3 or 5 W.r.t. 6 (MTL4544S only)

IIC 0.083 4.9 59

lIB* 0.65 20.0 222

IIA 2.15 40.9 469

I 3.76 59.1 710

* Group lIB parameters also applicable for associated apparatus [Ex ia Da] IIIC

Notes:

1) The above load parameters apply when one ofthe two conditions below is given:

- the total Lj ofthe external circuit (excluding the cable) is < 1% ofthe Lovalue or

- the total Ci ofthe external circuit (excluding the cable) is < 1% ofthe Co value.

The above parameters are reduced to 50% when both ofthe two conditions below are given:

- the total Lj ofthe external circuit (excluding the cable) is 1% ofthe Lovalue and

- the total Cj ofthe external circuit (excluding the cable) is 1% ofthe Co value.

The reduced capacitance ofthe external circuit (including cable) shall not be greater than I/-lF for Groups IIB, IIA

& I and 600nF for Group IIC.

MTL4541T Input / Output Parameters

Non-hazardous Area Terminals 8, 9, 11, 13 & 14

Urn 253V r.m.s.

The apparatus is designed to operate on non-hazardous area terminals 8, 9, 11, 13 & 14 from a d.c. supply voltage of up to

35V.

Hazardous Area Terminals 2 W.r.t. 1

22V

167mA

0.92W

o

o

Hazardous Area Terminals 3 W.r.t. 1

1.0V

53mA

14mW

30V

121mA

o

o

Although the apparatus does not comply with the simple apparatus requirements of Clause 5.7 of EN 60079-11: 2012,

when terminals 3 W.r.t. 1 are connected in an intrinsically safe circuit the internal stored energy, voltage and current ofthe

  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO HSL-4XMO-TB-D103 HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • AADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink  PICMG Single Board Computers  NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 industrial control motherboard
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC
  • ADLINK/AMPRO CM-435-v2/CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Technology 51-37111-0C1 PCB Interface Card
  • Adlink Centralized Motion Controllers PCI-8164
  • ADLINK PCI-7230/33/34 32-CH Isolated DIO PCI Cardsrd
  • ADLINK NUPRO-E320DV/NUPRO-E320 industrial control motherboard
  • Adlink PCI-8154 Advanced 4-axis Servo & Stepper Motion Controller
  • Adlink cPCI-3534/3538-S Series 4/8-port Asynchronous Serial Communications Modules
  • ADLINK Adlink Digital I/O PCI-7396
  • ADLINK 6U Rear Transition Modules cPCI-R6700 Series
  • ADLINK cPCI-6700B Industrial Control Board
  • ADLINK NuPRO-965/ NuPRO-965LV PICMG Single Board Computers
  • ADLINK HSL-DI16DO16-M-NN 16-CH Discrete Input 16-CH Discrete Output Module
  • Adlink cPCI-6770 6U CompactPCI 2.0 Blades
  • ADLINK NuPRO-598 REV A1 INDUSTRIAL CONTROL MOTHERBOARD
  • ADLINK PCI-7200 PCI Motion Control Card Acquisition Card 51-12001-0C20
  • ADLINK TECHNOLOGY EOS-1200/M4G/SSD32G(G) Industrial Systems
  • ADLINK Centralized Motion Controllers PCI-8134
  • ADLINK cPCI-HR6847E/M2G-1 COMPACT PCI BOARD
  • ADLINK PXIE-8638 BUS EXPANSION MODULE
  • ADLINK cPCI-6910 6U CompactPCI 2.0 Blades
  • Adlink NuPRO-E42 51-41808-0A30 Industrial Motherboard
  • ADLINK IH61-AA400-A4A1E (IMB-M40H) Industrial Motherboard
  • ADLINK PCIe-GIE64+ GigE Vision Frame Grabber Card
  • ADLINK MXC-6322D(G) Industrial Fanless Computer working
  • ADLINK CPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Module
  • Adlink cPCI-8168 Advanced 6U Compact PCI 8-Axis Motion Controller
  • Adlink VME CPU Board cPCI-6626/2710/M4G
  • ADLINK  cPCI-R6200 high-performance 6U CompactPCI Rear Transition Module (RTM)
  • Adlink cPCI-7248 48-CH Opto-22 Compatible Digital I/O Module
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nan