Features and benefits
Termination for up to eight (8) analog I/O process signals within a horizontal row.
All SD I/O modules & bases of all types (Singular or Redundant) AND (Compact or Full-size), are
100% fully compatible with each other. Thus, Singular & Redundant, Compact or Full-size I/O
modules can be mounted within a single, common HN800 I/O bus.
Optional mechanical keying can be implemented to prevent insertion of the wrong I/O module
type.
Latching device on the base locks the base into position on DIN-Rail.
Industry standard 35-mm DIN rail, Horizontal row mounting.
Time Synchronization
Enable Time Synchronization
Determines whether or not the Server receives and sends the time synchronization
on the network. When enabled, the Server is in time synchronization with the
control network.
Accuracy
Time synchronization accuracy of the Server is valid when the Server is in time
synchronization mode. The options are:
• Low accuracy (lowest accuracy); priority 0.
• Low accuracy battery backed; priority 3.
• High accuracy battery backed; priority 6.
• IIOIS20 node; priority 9.
• IIOIS20 SCSI; priority 10.
• PIMS SCSI; priority 11.
• Satellite clock system (highest accuracy); priority 12.
These accuracy settings are only used when negotiating for time mastership with
other nodes in the underlying Harmony control network.
Master Update Period
Master update period is the frequency that Harmony Server synchronizes time with
the underlying Harmony control network. This property is used only when Time
Synchronization is enabled. The permissible values are 120 to 3540 seconds.
Message Wait Period
Message wait period is the Period that Harmony Server waits before attempting to
assume time mastership on the control network. This property is used only when
Time Synchronization is enabled. The permissible values are between 180 and 3660
seconds. Additionally, the configured value must greater than the Master Update
Period.
Sending Global Alarm Acknowledgement Messages to the Loop
Enable Tag Acknowledgment Broadcast
To broadcast an alarm acknowledgement for a specific Harmony tag:
– Select the Tag Acknowledgment Broadcast Enable check box on the Harmony Tab of the tag. Selecting the
checkbox enables the connectivity server to broadcast the alarm acknowledgement for this tag on the communication highway.
Enable Acknowledgment Transmission
Configure the module status tag for each node to which the connectivity server transmits the alarm acknowledgment messages.
For each module status tag, on the Module tab, select the Enable Alarm Acknowledgment
Transmission check box to have the connectivity server transmit any recently acknowledged alarms.
Broadcasts will only be sent to a node when the corresponding module status tag is configured and has alarm acknowledgment transmission enabled.
Receiving Global Alarm Acknowledgement from the Loop
Configure the Harmony Server tag to enable receiving global alarm acknowledgment messages from other nodes on the loop.
On the Harmony tab, select the Global Alarm Acknowledgement check box to
enable the connectivity server to process the Global Alarm Acknowledgement messages received through the INFI-NET loop.
The connectivity server applies the alarm acknowledgement to the harmony tag that has the same Harmony address as the broadcast tag.
You may need the following additional products:
A-B 1769-L18ERM-BB1B CompactLogix 5370 L1 Controller
A-B 1769-L18ERM-BB1BK CompactLogix 5370 L1 Controller
A-B 1769-L19ER-BB1B CompactLogix 5370 L1 Controller
A-B 1769-L19ER-BB1BK CompactLogix 5370 L1 Controller
A-B 1769-L24ER-QB1B CompactLogix 5370 L2 Controller
A-B 1769-L24ER-QBFC1B CompactLogix 5370 L2 Controller
A-B 1769-L24ER-QBFC1BK CompactLogix 5370 L2 Controller
A-B 1769-L27ERM-QBFC1B CompactLogix 5370 L2 Controller
A-B 1769-L30ER CompactLogix 5370 L3 Controllers
A-B 1769-L30ERK CompactLogix 5370 L3 Controllers
A-B 1769-L30ERM CompactLogix 5370 L3 Controllers
A-B 1769-L30ERMK CompactLogix 5370 L3 Controllers
A-B 1769-L30ERMS CompactLogix 5370 L3 Controllers
A-B 1769-L30ER-NSE CompactLogix 5370 L3 Controller
A-B 1769-L32E EtherNet Processor
ABB SPK800-PBAT-03 HN800 to PBA to HN800 Cable 3.0 M
ABB SPK800-PBAT-04 HN800 to PBA to HN800 Cable 4.0 M
ABB SPK800-PBAT-0A HN800 to PBA to HN800 Cable 0.5 M
ABB SPRIORBX01K01 HN800 Remote I/O Kit Non-Redundant
ABB SPRIORBX01K02 HN800 Remote I/O Kit Redundant
ABB TER800 HN800 or CW800 Bus Terminator
ABB TER800A HN800 or CW800 Bus Terminator
ABB TER810 HN800 or CW800 Bus Terminator with cover
ABB TER810A HN800 or CW800 Bus Terminator with cover