DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

EMERSONMVME55006E Single-Board Computer Installation and Use

From:EMERSON | Author:LIAO | Time :2025-08-20 | 719 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Use extreme caution when handling, testing and adjusting.

Product Damage

Inserting or removing modules with power applied may result in damage to module 

components. 

Avoid touching areas of integrated circuitry, static discharge can damage these 

Procedure

This procedure assumes that you have read the user’s manual that came with your PMCs.

1. Attach an ESD strap to your wrist. Attach the other end of the ESD strap to an 

electrical ground. Note that the system chassis may not be grounded if it is 

unplugged. The ESD strap must be secured to your wrist and to ground throughout 

the procedure.

2. Perform an operating system shutdown. Turn the AC or DC power off and remove 

the AC cord or DC power lines from the system. Remove chassis or system cover(s) 

as necessary for access to the VME modules.

3. If the MVME5500 has already been installed in a VMEbus card slot, carefully 

remove it as shown in Figure 1-17 and place it with connectors P1 and P2 facing 

you. Remove the filler plate(s) from the front panel of the MVME5500.

4. Insert the appropriate number of Phillips screws (typically 4) from the bottom of the 

MVME5500 into the standoffs on the PMC module and tighten the screws (refer to 

Figure 1-15).

5. Align the PMC module’s mating connectors to the MVME5500’s mating connectors 

and press firmly into place.

1.8.2 Primary PMCspan

To install a PMCspan26E-002 PCI expansion module on your MVME5500, perform the 

following steps while referring to the figure on the next page:

Figure 1-15 Typical Placement of a PMC Module on a VME Module

Procedure

This procedure assumes that you have read the user’s manual that was furnished with your 

PMCspan.

1. Attach an ESD strap to your wrist. Attach the other end of the ESD strap to an 

electrical ground. Note that the system chassis may not be grounded if it is 

unplugged. The ESD strap must be secured to your wrist and to ground throughout 

the procedure.

2. Perform an operating system shutdown. Turn the AC or DC power off and remove 

the AC cord or DC power lines from the system. Remove chassis or system cover(s) 

as necessary for access to the VME modules.

3. If the MVME5500 has already been installed in a VMEbus card slot, carefully 

remove it as shown in Figure 1-17 and place it with connectors P1 and P2 facing 

you.

4. Attach the four standoffs to the MVME5500. For each standoff:

Insert the threaded end into the standoff hole at each corner of the MVME5500 and 

thread the locking nuts into the standoff tips and tighten.

5. Place the PMCspan on top of the MVME5500. Align the mounting holes in each 

corner to the standoffs and align PMCspan connector P4 with MVME5100 

connector J25.

Figure 1-16 PMCspan Installation on a VME Module

6. Gently press the PMCspan and MVME5500 together and verify that P4 is fully 

seated in J4.

7. Insert four short screws (Phillips type) through the holes at the corners of the 

PMCspan and into the standoffs on the MVME5500. Tighten screws securely.

1.8.3 Secondary PMCspan

The PMCspanx6E-010 PCI expansion module mounts on top of a PMCspanx6E-002. To install 

a PMCspanx6E-010, perform the following steps while referring to the figure on the next page:

Personal Injury or Death

Dangerous voltages, capable of causing death, are present in this equipment. 

Use extreme caution when handling, testing and adjusting.

Product Damage

Inserting or removing modules with power applied may result in damage to module 

components. 

Avoid touching areas of integrated circuitry, static discharge can damage these 

circuits.

Procedure

This procedure assumes that you have read the user’s manual that was furnished with the 

PMCspan, and that you have installed the selected PMC modules on your PMCspan according 

to the instructions provided in the PMCspan and PMC manuals.

1. Attach an ESD strap to your wrist. Attach the other end of the ESD strap to an 

electrical ground. Note that the system chassis may not be grounded if it is 

unplugged. The ESD strap must be secured to your wrist and to ground throughout 

the procedure.

2. Perform an operating system shutdown. Turn the AC or DC power off and remove 

the AC cord or DC power lines from the system. Remove chassis or system cover(s) 

as necessary for access to the VME module

3. If the Primary PMC Carrier Module and MVME5500 assembly is already installed in 

the VME chassis, carefully remove it as shown in Figure 1-17 and place it with 

connectors P1 and P2 facing you.

4. Remove four screws (Phillips type) from the standoffs in each corner of the primary 

PCI expansion module.

5. Attach the four standoffs from the PMCspanx6E-010 mounting kit to the 

PMCspanx6E-002 by screwing the threaded male portion of the standoffs in the 

locations where the screws were removed in the previous step.

6. Place the PMCspanx6E-010 on top of the PMCspanx6E-002. Align the mounting 

holes in each corner to the standoffs and align PMCspanx6E-010 connector P3 with 

PMCspanx6E-002 connector J3.

7. Gently press the two PMCspan modules together and verify that P3 is fully seated 

  • CTI 2500-ADP2-DISC Discrete Wiring Adapter for Series 500
  • CTI 2500-ADP1 Analog Wiring Adapter for Series 500
  • CTI 2500C-RADP-RS485 Remote Base Controller Adapter for Series 500
  • CTI 2500C-RADP-RBC Profibus RBC Adapter for Series 500
  • CTI 2500C-PADP-120V 120VAC 50W Power Supply for Series 500
  • CTI 2500-RADP RBC Adapter for Series 500
  • CTI 2500-R4500 520/530/DBC Adapter for Series 500 - MATURE
  • CTI 2500-PADP Power Supply Adapter for Series 500
  • CTI 2500-IADP I/O Adapter for Series 500
  • CTI 2500-VP15A-N4-W7 15" Flat-Panel PC with Windows® 7 Embedded
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 8DIO / 2UAI
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1550 Slice I/O, RS232/485. 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1550 Slice I/O, RS232/485. 8DIO / 2UAI
  • CTI 2500S-23-1550 Slice I/O, RS232/485. 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1050 Slice I/O, Ethernet, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1050 Slice I/O, Ethernet, 8DIO / 2UAI
  • CTI 2500S-23-1050 Slice I/O, Ethernet, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500C-32F-CJC 32-Pin Field Wiring Connector with Cold Junction Compensation
  • CTI 2500C-32F 32-Pin Field Wiring Connector
  • CTI 2500C-8-TC Eight Thermocouple Inputs
  • CTI 2500C-8-RTD Eight RTD Inputs
  • CTI 2500C-8-RL-FC 8 Form-C Relay Outputs
  • CTI 2500C-8-IDO-24V 8 Isolated 24VDC Outputs
  • CTI 2500C-8-IDO-120V 8 Isolated 120VAC Outputs
  • CTI 2500C-16-DO-24V Sixteen 24VDC Digital Outputs
  • CTI 2500C-16-DO-120V Sixteen 120VAC Digital Outputs
  • CTI 500C-16-IDI-24V Sixteen Isolated 24V AC/DC Digital Inputs
  • CTI 2500C-16-IDI-120V Sixteen Isolated 120V AC/DC Digital Inputs
  • CTI 2500C-16-DIDO-SIM Sixteen Digital Input and Output SImulator
  • CTI 2500C-16-DI-24V Sixteen 24V AC/DC Digital Inputs
  • CTI 2500C-16-DI-120V Sixteen 120V AC/DC Digital Inputs
  • CTI 2500C-RBC-RS485 RS485 Remote Base Controller
  • CTI 2500C-RBC-PRF Profibus Remote Base Controller
  • CTI 2500C-PS-24V-35 35-Watt DC Power Supply
  • CTI 2500C-PS-120V-35 35-Watt AC Power Supply
  • CTI 2500C-R8 Eight-Slot Base
  • CTI 2500C-R4 Four-Slot Base
  • CTI 2500C-R16 Sixteen-Slot Base
  • CTI 2500C-2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2500C-J750 Compact Janus PAC with 3MB Project Memory
  • CTI 2500C-C300 CPU with 512K User Memory
  • CTI 2500C-C200 CPU with 256K User Memory
  • CTI 2500C-C100 CPU with 128K User Memory
  • CTI 2500C-8-AO 8 Analog Outputs
  • CTI 2500C-8-AI 8 Analog Inputs
  • CTI 2559-FCAL Precision Calibration Connector
  • CTI 2559-FPC 40-Position Screw-Terminal Connector
  • CTI 2500-RFC PLC to RF Modem Cable
  • CTI 2500-40F 40-Position Standard Screw-Terminal Connector
  • CTI 2505 Vibration Sensor Interface Module
  • CTI 2554-A 4-Channel Isolated High Speed Counter Module
  • CTI 2553-A 2-Channel Mag Meter Input Module
  • CTI 2502 2-Channel High Speed Counter Input Module
  • CTI 2559-TC 8-Channel Thermocouple Input Module
  • CTI 2556-A 16-Channel Isolated Thermocouple Input Module
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2551-A 8-Channel Isolated Thermocouple Input Module
  • CTI 2559-RTD 8-Channel RTD Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2557 16-Channel RTD Input Module
  • CTI 2552-A 8-Channel Isolated RTD Input Module
  • CTI 2534 8-Point Form-C Relay Output Module
  • CTI 2532 16-Point Form-A Relay Output Module
  • CTI  2531 32-Point Form-A Relay Output Module
  • CTI  2530 8-Point Form-C Relay Output Module
  • CTI  2562 8-Channel Analog Output Module
  • CTI  2560-A 8-Channel Isolated Analog Output Module
  • CTI  2501 8in/4out Analog Module
  • CTI  2558 8-Channel Analog Input Module
  • CTI  2555-A 16-Channel Analog Input Module
  • CTI  2550-A 8-Channel Isolated Analog Input Module
  • CTI  2599 8/16/32-Point AC Output Module
  • CTI  2598-8 8-Point AC Output Module
  • CTI   2598 8/16-Point AC Output Module
  • CTI   2597 8/16/32-Point DC Output Module
  • CTI 2596-8 8-Point DC Output Module
  • CTI 2596 8/16-Point DC Output Module
  • CTI 2595 16-Point TTL/Word Output Module
  • CTI 2591-EF 16-Point Isolated 11-146 VDC Output with Front Panel Accessible Fuses
  • CTI 2591-A 16-Point Isolated 11-146 VDC Output Module
  • CTI 2590-EF 16-Point Isolated 20-132 VAC Output with Front Panel Accessible Fuses
  • CTI 2590-A 16-Point Isolated Discrete 20-132 VAC Output Module
  • CTI 2589-B 8/16/32-Point Universal Discrete Input Module
  • CTI 2589-A 8/16/32-Point Universal Discrete Input Module
  • CTI 2588-8 8-Point Universal Discrete Input Module
  • CTI 2585 16-Point TTL/Word Input Module
  • CTI 2582 16-Point Isolated 125 VDC Input Module
  • CTI 2581 16-Point Isolated 12-56 VDC Input Module
  • CTI 2580 16-Point Isolated 95-132 VAC Input Module
  • CTI 2500-TAP RS485 Network Tap
  • CTI 2500-RIO-B RS485 Remote Base Controller
  • CTI 2500-RIO-A RS485 Remote Base Controller
  • CTI 2500-RBC Profibus Remote Base Controller
  • CTI 2515-A 100-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2515 100-Watt AC Power Supply (MATURE - replaced by 2515-A)
  • CTI 2513-A 75-Watt DC Power Supply with Redundancy Support
  • CTI 2513 75-Watt 24VDC Power Supply
  • CTI 2512-A 75-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2512 75-Watt AC/DC Power Supply
  • CTI 2510 125 VDC Power Supply
  • CTI 2500-SSB Single Slot Blank Front Panel
  • CTI 2500-R11-A Eleven-Slot Redundant Base
  • CTI 2500P-R16 Sixteen-Slot Base with High-Speed Channel
  • CTI 2500P-R8 Eight-Slot Base with High-Speed Channel
  • CTI 2500P-R4 Four-Slot Base with High-Speed Channel
  • CTI 2541 Redundant Processor Manager Module
  • CTI 2577 Profibus DP Slave Adapter
  • CTI 2573-MOD Serial Interface Adapter with MODBUS
  • CTI 2572-AF Fast Ethernet TCP/IP Adapter with Optical Fiber Connection
  • CTI 2572-A Fast Ethernet TCP/IP Adapter
  • CTI 2572 Ethernet TCP/IP Adapter
  • CTI 2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2576 DeviceNet™ Scanner Module (MATURE)
  • CTI 2500P-ECC1 Ethernet Communications Coprocessor
  • CTI 2500P-JACP Janus Application Coprocessor
  • CTI 2500P-ACP1 Application Coprocessor (MATURE - replaced by 2500P-JACP)
  • CTI 2500P-J450 Janus PAC with 2MB Project Memory
  • CTI 2500-C400 CPU with 3072K User Memory
  • CTI 2500-C300 CPU with 512K User Memory
  • CTI 2500-C200 CPU with 256K User Memory
  • CTI 2500-C100 CPU with 128K User Memory
  • CTI 2500P-J750 Janus PAC with 3MB Project Memory
  • Shinkawa WHF3006M Displacement Converter
  • Shinkawa JBP-220 (P-24-94A / P-24-94B) Circuit Board Module
  • SHINKAWA   WKN-142K5  2-WIRE VIBRATION TRANSDUCER
  • Shinkawa FRP-321 (P-26-54A / P-26-54B) Circuit Board Module