369B1859G0021 PCB assembly
The GE 369B1859G0021 is a replacement printed circuit board (PCB) assembly designed for the GE Multilin 369 Motor Management Relay.
It is not a standalone relay or a standard PLC I/O module, but a critical internal component used for repair, refurbishment, or upgrading of the 369 series relay.
This assembly typically includes the main processor board or a major functional sub-assembly of the relay, which houses the microprocessor, memory, communication chips, and related circuitry responsible for the relay’s motor protection, monitoring, and control logic.
When a critical failure occurs on the original PCB, the 369B1859G0021 provides a factory-specified solution to restore the relay to full operation. For definitive identification and compatibility, the service manual for the specific 369 relay and the official parts list for the GE 369B1859G0021 are essential.
Technical Parameters and Characteristics
As a PCB assembly, the 369B1859G0021 encompasses the core electronics of the motor management relay:
Parent Device: GE Multilin 369 series Motor Management Relay (specific models like 369-HI-R-M-F-0. etc.).
Function: Main Control/Processor Board Assembly.


Core Components: Includes the main microprocessor, non-volatile memory (for settings and logs), real-time clock, and the logic for executing protection algorithms (overload, jam, undercurrent, phase unbalance, ground fault, etc.).
Communication Interfaces: The board contains the physical layer for communication ports, which may include RS-485 (Modbus RTU), Ethernet, or other proprietary GE communication protocols, depending on the relay variant.
Firmware: The board may come with a specific firmware version installed or may require a field update to match the system requirements. The correct operation of the 369B1859G0021 is dependent on compatible firmware.
Compatibility: This part number is specific to certain hardware revisions of the 369 relay. It is not universally compatible with all 369 relays. The exact relay model and serial number must be checked against GE’s parts interchange documentation.
Key Advantages and Features
Utilizing the official GE replacement board 369B1859G0021 offers significant advantages over unofficial repairs:
Guaranteed Compatibility and Performance: As a genuine GE part, the 369B1859G0021 is engineered to meet the original design specifications for electrical performance, thermal characteristics, and safety certifications (UL, CE, etc.), ensuring the relay operates as intended.
Preservation of System Integrity: Replacing a failed board with this certified assembly maintains the relay’s calibrated accuracy for current sensing and its certified performance for safety-critical motor protection functions.
Simplified Repair Process: For trained technicians, swapping the main PCB assembly can be a faster and more reliable repair method than troubleshooting and replacing individual surface-mount components. It returns the asset to service with minimal downtime.
Access to Latest Revisions: Service parts like the 369B1859G0021 often incorporate product improvements and component lifecycle updates that were not present in the original board, potentially improving long-term reliability.
Application Cases in Various Fields
The GE 369B1859G0021 PCB is used in repair scenarios across all industries that utilize the GE Multilin 369 relay for motor protection:
Water/Wastewater Treatment Plants: Repairing relays that protect critical raw water intake pumps, aeration blowers, and sludge transfer pumps.
Oil & Gas Facilities: Restoring protection for ESP (Electric Submersible Pump) motors, compressor motors, and cooling tower fan motors.
Mining and Minerals Processing: Fixing relays on crusher motors, conveyor drives, and ball mill motors where vibration and dust can lead to electronic failures.
HVAC for Large Facilities: Repairing motor protection for large chilled water pumps and cooling tower fans in data centers or hospitals.
Comparison with Competing Products
The competition for the 369B1859G0021 is not other brands of motor relays, but alternative repair strategies:
Third-Party Repair Services: These services may repair the existing PCB using generic components. While potentially cheaper, they may not guarantee original performance specs or safety certifications.
Complete Relay Replacement: Replacing the entire 369 relay with a new unit (e.g., a newer 369 model or a competitor’s relay like the Siemens SIPROTEC Compact or ABB CMA). This is more expensive but provides a new warranty and potentially newer features.
Unofficial/Clone PCBs: Lower-cost replica boards may be available. These carry significant risks regarding performance, safety, reliability, and may violate the original equipment warranty or safety certifications. The genuine 369B1859G0021 is the only recommended part for maintaining system integrity.
Selection Suggestions and Precautions