DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
IS220PPRAS1A
❤ Add to collection

IS220PPRAS1A

IS220PPRAS1A
10055.00
¥4548.00
¥4548.00
¥4548.00
Weight:0.000KG
Description
IS220PPRAS1A

Part Number IS220PPRAS1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS220PPRAS1A is an Emergency Turbine Protection Terminal Board manufactured and designed by General Electric as part of the Mark VIe Series used in distributed control systems. A backup Overspeed protection system that is independent is offered by the Emergency Turbine Protection (PPRA) I/O packs and related TREA terminal board. Inputs for the main control and isolated trip contacts are also given a separate watchdog role by them. A protection system is made up of three triple modular redundant (TMR) PPRA I/O packs that are mounted to a TREA terminal board and have a WREA option board attached. The standard Mark VIe PPRO Emergency Turbine Protection I/O pack is the ancestor of PPRA. In applications where dual-speed sensors per shaft are fanned to three protective I/O packs, it needs new hardware and modified code to provide six-speed inputs. The majority of the PPRA's settings, parameters, and behavior are the same as those in the PPRO. The TREA terminal board with the WREA option board is the only one that supports PPRA. Other settings that PPRO supports cannot be used with PPRA. In order to communicate with the control modules through IONet, PPRA additionally has an Ethernet connection. The primary and backup trip prevention systems for the Mark VIe control are built to work together at the trip terminal board level. The Turbine Primary I/O pack (PTUR), when connected with PPRA/TREA, operates a primary trip board (usually TRPA), providing primary protection. A TREA terminal board installed with PPRA offers backup protection. PPRA supports six-speed signals (specified as three sets of speed pairs) for hardware-implemented Overspeed protection, acceleration, and deceleration. It keeps an eye on the primary control's performance. Through a thorough set of feedback signals, PPRA keeps track of the status and functionality of the TREA trip board. The backup trip relays on the TREA board will trip in the event of a failure, and the primary control will also trip. The primary control operation has no impact on PPRA and is completely independent of it. COMPATIBILITY: For usage in IEC 61511-approved safety loops, PPRA is offered in a version that is IEC 61508 certified. The certified versions of the PPRA module are PPRAS1A with TREAS1A and WREAS1A. When using TREA, which PPRA mounts on directly, the WREA option board must be installed on the PPRA application-specific circuit board Option Header connector. Only three PPRA I/O packets will work properly with a PPRA installed on a TREA with WREA. It is not possible to operate a single or twin pack. In systems with a single controller, the R network of the controller, the S network of the controller, the JY1 connector of the controller, and the JZ1 connector of the controller should all be linked to the PPRA. The same controller powers all three networks. INSTALLATION: Mount the TREA terminal board firmly. Immediately connect the TREA with three PPRA I/O packets. Using the holes on the terminal board mounting bracket, insert the threaded posts on PPRA that are situated on either side of the Ethernet ports. To ensure a tight fit between the DC-62 pin connector on the PPRA and the terminal board, adjust the bracket's position. Secure the mounting bracket firmly. Only one adjustment should be necessary during the lifespan of the product. Lock PPRA in place by firmly tightening the nuts on the threaded posts. Depending on the setup of the machine, connect either one or two Ethernet wires. Ethernet connections are not sensitive to PPRA, which chooses the appropriate operation over either port. Connect the module's power connector to an electrical source to supply power. The I/O module has a built-in soft-start feature that regulates current levels when used. Configure the module using the ToolboxST* program as appropriate. OPERATION: A processing board is shared by each Mark VIe Ethernet I/O pack or module. It contains the following: A quick processor with RAM and flash memory is number one. Two plugs for entirely independent 10/100 Ethernet ports Hardware reset and watchdog timer circuit A sensor for internal temperature LEDs that indicate the status The capacity to read IDs on other boards and electronic identification An input power connector with a current limiter and a soft start Local power supplies, which also include monitoring and sequencingIO PACK, SPEED IN PROTECTION


  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI
  • ABB Control product - Soft starter PST/PSTB (Intelligent Type)
  • ABB Automation System ABB Procontic T200
  • ABB PCS6000 medium voltage wind turbine converter
  • SYSTEM DRIVES PCS6000 ABB
  • ABB PP886 Compact Product Suite hardware selector
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Panel 800 Version 6- PP885
  • ABB IndustrialIT Panel 800 - PP846 Version 5.1
  • ABB IndustrialIT Panel 800 - PP836 Version 5.1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • ABB Advant® Master S100 I/O system
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • GE Reason RT431 GPS Precision-Time Clock
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany (2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • Advant™Automation with MOD 300™ Software
  • ABB MEASUREMENT & ANALYTICS EasyLine EL3000 / EL3060
  • ABB MEASUREMENT & ANALYTICS PGC5000 Process gas chromatograph
  • ABB AC servo motors BSM Series
  • ABB New BSD Series A complete range
  • ABB Advant Controller 110
  • ABB ASTAT® Crane motion controller Version AST10_054
  • ABB-Crane Control System - ASTAT
  • ABB Open Control System Advant Controller 210
  • ABB Open Control System Advant Controller 250
  • ABB Advant Controller 160
  • ABB DSCA33 High Performance Signal Conditioners
  • ABB Advant Controller 70 – Kompakter und leistungsfähiger
  • ABB Advant Controller 31 Hardware 90 Series