DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
IS200VTURG1B
❤ Add to collection

IS200VTURG1B

IS200VTURG1B
10055.00
¥4548.00
¥4548.00
¥4548.00
Weight:0.000KG
Description
IS200VTURG1B

Part Number IS200VTURG1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200VTURG1B is a turbine specific primary trip board developed by GE. It is a part of Mark VI control system. It employs four passive pulse rate devices to accurately measure the speed of the turbine. These measurements are transmitted to the controller, which utilizes this data to generate the primary overspeed trip signal. This overspeed trip mechanism acts as a crucial safety feature, ensuring that the turbine does not exceed safe operational speeds, thereby preventing potential damage or catastrophic failure. FEATURES Generator Synchronization and Breaker Closure: Additionally, it facilitates the automatic synchronization of the generator.Once synchronization is achieved, it coordinates the closure of the main breaker, allowing the generated power to be efficiently transmitted through the electrical system. Monitoring Shaft Voltage and Current: Equipped to monitor the induced voltage and current on the turbine shaft. This monitoring capability is vital for detecting any irregularities or abnormalities in the turbine's operation, enabling timely intervention to prevent damage or malfunction. Flame Detection: In gas turbine applications, oversees the operation of eight Geiger Mueller flame detectors. These detectors, connected to the TRPG, are supplied with 335 V DC and 0.5 mA from an external source. The function of these detectors is to detect the presence or absence of flames within the turbine, providing critical information for maintaining safe combustion processes. Overspeed Trip Control: Controlling the primary overspeed trip relays on the TRPG terminal board. It generates the trip signal based on the turbine speed measurements and other relevant parameters. This trip signal is then transmitted to the TRPG, initiating the activation of emergency solenoids to trigger the turbine overspeed trip. Notably, it can receive overspeed trip signals from both itself and VPRO, providing redundancy and enhancing system reliability. Interface with Electrical Trip Devices (ETD): Within the TRPG, nine magnetic relays interface with three trip solenoids, collectively known as Electrical Trip Devices (ETD). These relays, nine in total for Triple Modular Redundancy (TMR) systems and three for simplex systems, serve to ensure the reliable operation of the trip mechanisms. By coordinating with VTUR and other components, the ETDs play a crucial role in swiftly and effectively executing turbine shutdown procedures in response to critical events like overspeed conditions. INSTALLATION Power Down the VME Processor Rack:Prior to installation, it's crucial to power down the VME processor rack to prevent any electrical interference or potential damage to the components. This step involves safely shutting down any associated systems and disconnecting power sources to the VME rack to ensure a secure installation environment. Slide in the Board: With the VME processor rack powered down, the next step is to carefully slide the board into the designated slot within the rack. Precision is key during this process to align the board correctly with the slot and ensure a proper fit. Once the board is positioned correctly, apply gentle pressure to push the top and bottom levers in with your hands. This action secures the edge connectors of the board firmly in place within the slot, establishing electrical connectivity with the rack and other components. Secure with Captive Screws:After seating the board in the slot, the final step is to secure it in position by tightening the captive screws located at the top and bottom of the front panel.Captive screws are designed to remain attached to the panel even when loosened, simplifying the installation process and reducing the risk of misplaced hardware. Tightening these screws ensures that the board remains securely fastened within the rack, minimizing the potential for displacement or instability during operation. FAST OVERSPEED TRIP PR_Single: This algorithm utilizes redundant VTUR packs, distributing the workload across two separate boards. Each redundant PR (Pulse Rate) transducer is assigned to one board, ensuring redundancy and enhancing reliability. PR_Single is the preferred algorithm for LM (Land and Marine) gas turbines, offering a robust overspeed protection mechanism tailored to the specific requirements of these turbines. PR_Max: In contrast to PR_Single, PR_Max utilizes a single VTUR pack connected to two redundant PR transducers. This configuration allows for broken shaft detection and deceleration protection while mitigating the risk of nuisance trips in the event of transducer failure. PR_Max offers a balanced approach, combining effective overspeed protection with enhanced fault tolerance, thereby ensuring the uninterrupted operation of the turbine under diverse operating conditions.VME TURBINE CARD

  • Sixnet® SL-8ES-1 Unmanaged 8-port Industrial Ethernet Switch
  • ABB NE810 3BSE080207R1 Network switch
  • N-Tron® 1008TX Unmanaged 8-port Gigabit Industrial Ethernet Switch
  • N-Tron® 106FX2-SC-MDR Unmanaged 6-port Industrial Ethernet Switch
  • Sixnet® SLX-9ES-3SC Unmanaged 9-port Industrial Ethernet Switch
  • N-Tron® 106FXE2-SC-80-MDR Unmanaged 6-port Industrial Ethernet Switch
  • Sixnet® SLX-5ES-3SC Unmanaged 5-port Industrial Ethernet Switch
  • Emerson Smart Wireless Gateway 1552WU
  • Emerson wireless control bridge
  • Emerson field data is wirelessly transmitted back
  • Emerson Wireless Remote Video Surveillance
  • Emerson DeltaV™ S series 4-port FF fieldbus I/O
  • Emerson DeltaV™ S series DeviceNet interface cards
  • Emerson DeltaV™ S series H1 I/O card with integrated power supply
  • Emerson DeltaV™ S series centralized connection solutions
  • Emerson DeltaV™ S series Profibus DP interface card
  • Emerson DeltaV™ S series serial interface
  • Emerson DeltaV™ S series SX controller
  • Emerson DeltaV™ Recipe Exchange
  • Emerson DeltaV™ Mobile
  • Emerson DeltaV™ M Series enhanced DC-to-DC power supply
  • Emerson DeltaV™ Virtual S Series and M Series controller simulation
  • Emerson DeltaV™ PK Flex controller
  • Emerson DeltaV Flex system
  • Emerson DeltaV™ M series Profibus DP Series 2 Plus interface card
  • Emerson DeltaV CTO DCS cabinet
  • Ntron Senz-TX oxygen sensor transmitter
  • ntron Compact SIL2 Capable Oxygen Analyzer – Ntron SIL-O2
  • Oxygen Analyzer – Ntron Microx
  • Medical Gas Analyzer – Ntron MoGas
  • Intrinsically Safe Compact Oxygen Transmitter – Minox-i
  • Ntron Microx-OL
  • Portable Oxygen and Moisture Analyzer – Ntron AM Trace
  • In-Line Process Oxygen Analyzer – Ntron OxyExtract
  • Ambient Oxygen Analyzer – Ntron Gasenz
  • Portable Oxygen Analyzer – Ntron Yellow Box
  • Industrial Oxygen Analyzers – GPR-1900 and GPR-2900
  • Oxygen Monitors – AII GPR-1500 GB/2500 GB
  • Thermo-Paramagnetic Oxygen Analyzer – Michell XTP501
  • Paramagnetic Oxygen Analyzer – Michell XPM601
  • N-Tron® NT24K-12GX4-SC-80 Industrial Ethernet Switch
  • N-Tron® NT24K-14FXE6-SC-80 Managed 14-Port Gigabit Industrial Ethernet Switch
  • N-Tron® 7012FXE2-SC-40 Managed 12-port Industrial Ethernet Switch
  • N-Tron® NT24K-11GX3-SC-PT Gigabit Industrial Ethernet Switch
  • N-Tron® NT24K-14FXE6-SC-15 Managed 14-Port Gigabit Industrial Ethernet Switch
  • N-Tron® 7018FXE2-SC-15 Managed 18-port Industrial Ethernet Switch
  • N-Tron® NT24k 24-Port Rackmount Gigabit Managed Industrial Ethernet Switch
  • N -Tron® 710FXE2-ST-80 Managed 10-port Industrial Ethernet Switch
  • N-Tron® NT24k 24-Port, Dual Redundant VDC Power Input
  • N -Tron® 712FXE4-SC-15-HV Industrial Ethernet Switch
  • N -Tron® 712FXE4-ST-15-HV Industrial Ethernet Switch
  • N-Tron® NT24K-10FX2-SC Industrial Ethernet Switch
  • N -Tron® 709FXE-SC-40 Managed 9-port Industrial Ethernet Switch
  • N-Tron® NT24K-12SFP-DM4 Gigabit Industrial Ethernet Switch
  • N-Tron® NT24k 16-Port, Single Redundant VDC Power Input
  • GE Multilin C30 Controller System
  • GE Multilin C650 Bay Control & Monitoring System
  • GE Reason MU320E
  • GE Reason MU360
  • GE MiCOM C264 Bay Controller
  • GE Multilin C60/C95 C60 Breaker Monitoring and Control
  • GE Multilin D.20 I/O Modules
  • GE Multilin D20E Advanced Substation I/O Modules
  • GE Multilin™ G500 Advanced Substation Gateway
  • GE Multilin™ G100 Advanced Substation Gateway
  • GE iSTAT i4Mx Standard multifunction transducer
  • iSTAT M365 Power Quality Metering with Extensive Logging and Communications
  • GE iSTAT M2x3 High Performance Measurement Centre
  • GE iSTAT M2x2 Standard Measurement Centre family
  • iSTAT i400 Mean Sensing Transducers and i4XS Communications Interface
  • GE iSTAT i500 High Performance Multifunction Transducer
  • GE MVTP Buswire Supervision Relay
  • GE MFAC High Impedance Bus Differential Relay
  • GE MCAG High Impedance Bus Differential Relay
  • GE P40 Agile P14N, P14D, P94V P40 Agile Feeder Management
  • GE MiCOM Agile P140 Series
  • GE MiCOM Agile P746 Centralized Busbar Differential Relay
  • GE MiCOM Agile P747 Centralized Busbar Differential Relay
  • GE Multilin B90 Low Impedance Bus Protection System
  • GE MiCOM Agile P74x Series
  • GE Multilin B30 Multiple Sections Low Impedance Busbar Protection
  • GE Dolin G60 generator protection system
  • ABBPCS 8000 AC Excitation AC Excitation for hydro pump energy storage plants
  • ABBCompact Product Suite Panel 800 Version 6 PP877 Hardware and Installation
  • ABBIndustrialIT Panel 800 - PP865 Version 5.1 Hardware and Installation
  • ABBSYSTEM DRIVES MEGADRIVE-LCI water-cooled User manual
  • ABBAdvant® Controller 450 The proven process controller
  • ABBAdvant® Master S100 I/O system
  • SYNCHROTACT® 5 Operating Instructions SYN 5201 SYN 5202
  • ABB EXCITATION SYSTEMS AND SYNCHRONIZING EQUIPMENT SYNCHROTACT® 5 Documentation Access
  • ABBAdvant® Master S100 I/O system
  • ABBCI853 Compact Product Suite hardware selector
  • ABBAC 800M and Communication interfaces Compact Product Suite Outline of all modules
  • ABBAC 800M Controller Hardware Product Guide
  • ABBAC 800M PROFIBUS DP Configuration
  • ABBCompact control system replaces PLCs Comfortable, more efficient integration of package units using AC 700F
  • ABBDistributed busbar protection REB500 including line and transformer protection Product Guide
  • ABB Procontic Progamming System 907 PC 331 Programming and Test Software
  • ABBDCS800 Quick guide DCS800 Drives (20 A to 5200 A)
  • ABBDCS Thyristor Power Converters for DC Drive Systems 25 to 5150 A Operating Instructions DCS 600 MultiDrive
  • ABBDrivetrain vibration damping with MEGADRIVE-LCI Improve reliability, extend lifetime and enhance performance
  • ABBMEGADRIVE-LCI water-cooled User manual
  • ABBDCS800 Hardware Manual DCS800 Drives (20 to 5200 A)
  • ABBDCS800 Quick guide DCS800 Drives (20 A to 5200 A)
  • ABBDCS Thyristor Power Converters for DC Drive Systems 25 to 5150 A Operating Instructions DCS 600 MultiDrive
  • ABBAdvant® OCS Open Control SystemAdvant Controller 110
  • ABBAdvant® OCS Open Control SystemAdvant Controller 210
  • ABBAdvant Fieldbus 100 User Manual
  • ABBAdvant® OCS Open Control SystemAdvant Controller 250
  • ABBAdvant Controller 160
  • ABBIndustrial Networks Connecting Controllers via OPC
  • ABBAdvant® OCSOpen Control SystemAdvant Controller 70
  • ABBAdvant Controller 31 40 & 50 Series
  • ABB Procontic CS 31 Intelligent decentralized automation system
  • ABBAdvant Controller 31 Intelligent Decentralized Automation System
  • ABBHardware Manual ACV 700 Frequency Converters
  • ABBGet more done better with Advant Controller 400 series
  • ABBElectro-Pneumatic Positioner TZIDC
  • ABBCase note ABB MNS iS The integrated solution for the WAGP project
  • ABBCondition MonitoringMService V7.7 - User Manua MService V7.7 - User Manua [Document Type] ABB Ability™ Condition Monitoring for electrical systems - CMES User Manual MService Condition Monitoring V7.7 User Manual
  • ABBMNS® Digital ABB Ability™ Condition Monitoring for electrical systems - CMES User Management – Quick guide ABB Ability™ Condition Monitoring for electrical systems – CMES User Management Quick Guide
  • ABB MEASUREMENT & ANALY TICS | DATA SHEET 266DSH Differential pressure transmitters
  • General Specifications FCN Autonomous Controller Hardware (FCN-500)
  • Unicom-JETNETJetNet 4510 Industrial 10-port Management Fast Ethernet Switch
  • TCC-80Port-powered RS-232 to RS-422/485 converter
  • Temaline Wiegand ModuleDigital Wiegand Multi I/O Management Device
  • ABBAC 800M Controller Hardware
  • MD00R-02/04 - Industrial PLC Workstation