DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
IS220PRAS1A
❤ Add to collection

IS220PRAS1A

IS220PRAS1A
10055.00
¥4548.00
¥4548.00
¥4548.00
Weight:0.000KG
Description
IS220PRAS1A

Part Number IS220PRAS1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS220PRAS1A is a protection I/O module developed by GE. It is a part of Mark VIeS control system. It is a component used in GE Distributed Control Systems, specifically designed for independent backup overspeed protection and watchdog functions for primary control systems. The I/O packs and associated terminal board provide an independent backup overspeed protection system. Features Independent Watchdog Function: The module monitors the primary control system continuously, providing an additional layer of oversight to ensure system integrity and operational continuity. Isolated Trip Contact Inputs: It incorporates secure and reliable isolated inputs for turbine trip commands, crucial for initiating protective actions in response to critical operational conditions. I/O Packs and Terminal Board: Derived from the standard Mark VIe packs, the I/O packs support up to six-speed inputs, accommodating dual-speed sensors per shaft. This design flexibility allows for versatile integration and adaptation to specific turbine configurations. The terminal board is tailored to ensure seamless compatibility and integration with the overall control system architecture, maintaining consistency in configuration, variables, and operational behavior. Ethernet Connectivity: Equipped with Ethernet connections, the module facilitates IONet communications with control modules. This connectivity feature supports efficient data exchange and integration within the broader control network, enhancing system monitoring and control capabilities. Application: The module is instrumental in critical applications where reliable overspeed protection and continuous monitoring of primary control systems are paramount. Its features, including independent watchdog functionality






, isolated trip inputs, and Ethernet connectivity, underscore its role in maintaining operational safety, reliability, and compliance with industry standards. Operations The soft-start circuit is responsible for gradually ramping up the voltage supplied to the processor board. This gradual increase in voltage helps prevent sudden electrical surges that could potentially damage sensitive components. By controlling the rate of voltage increase, the soft-start circuit ensures that the processor board powers up safely and reliably. Local power supply sequencing is crucial for proper distribution and monitoring of power within the control system. It involves a systematic approach to powering up various components in a specific order to prevent power spikes or instabilities. Proper sequencing ensures that each component receives stable power at the correct voltage levels, optimizing performance and longevity. During processor initialization, several key tasks are performed to prepare the processor board for operation Processor Reset Removal: This step involves removing the processor reset signal, allowing the processor to begin executing its startup routines. Self-Test Routines: The processor runs self-test routines to check internal components and subsystems for proper functioning. This diagnostic process verifies that the processor board is operational and ready to execute tasks. Loading specific application code from flash memory is essential for configuring the processor board to perform its designated tasks. The application code contains instructions and algorithms tailored to the control system芒聙聶s operational requirements. Loading this code initializes the board with the necessary software components, enabling it to carry out control functions effectively. Board ID verification ensures the correct matching of application code, acquisition board, and terminal board configurations. This verification process confirms that the installed software matches the hardware configuration, preventing compatibility issues and ensuring seamless operation of the control system. Establishing Ethernet communications involves setting up network connectivity for the processor board. This step includes: Network Address Request: The processor requests a network address from the network infrastructure to establish communication. Network Communications: Once connected, Ethernet facilitates data exchange between the processor board and other networked devices or systems. It supports real-time monitoring, control, and data transfer essential for system operation. Processor Board Components High-Speed Processor: The board features a high-speed processor that includes both RAM and flash memory. This setup ensures efficient processing and storage capabilities, essential for handling complex tasks and maintaining high performance. Dual Ethernet Ports: The board is equipped with two fully independent 10/100 Ethernet ports. These ports provide robust network connectivity and allow for simultaneous data transmission without interference. Watchdog Timer and Reset Circuit:A watchdog timer is included to monitor the processor芒聙聶s operation and initiate a reset if the system becomes unresponsive. This feature is crucial for maintaining system reliability and minimizing downtime. Internal Temperature Sensor: An internal temperature sensor is integrated to monitor the board芒聙聶s thermal conditions. This component helps ensure the board remains within safe operating temperatures, thus preventing overheating and potential damage. Status-Indication LEDs: The board includes status-indication LEDs that provide visual feedback on the system芒聙聶s operational state. These LEDs help users quickly assess the board's status and identify any issues. Electronic ID and Inter-Board Communication: The board features an electronic ID system for unique identification and inter-board communication. This component facilitates effective communication between multiple boards within a system, enhancing overall functionality and integration. Input Power Connector: The input power connector is designed with soft start and current limiting capabilities. This feature helps protect the board from power surges and ensures a smooth startup process. Local Power Supplies: The board includes local power supplies with sequencing and monitoring functions. These supplies provide stable power to the board and ensure consistent operation by managing voltage levels and detecting any irregularities.I/O PACK

  • Sixnet® SL-8ES-1 Unmanaged 8-port Industrial Ethernet Switch
  • ABB NE810 3BSE080207R1 Network switch
  • N-Tron® 1008TX Unmanaged 8-port Gigabit Industrial Ethernet Switch
  • N-Tron® 106FX2-SC-MDR Unmanaged 6-port Industrial Ethernet Switch
  • Sixnet® SLX-9ES-3SC Unmanaged 9-port Industrial Ethernet Switch
  • N-Tron® 106FXE2-SC-80-MDR Unmanaged 6-port Industrial Ethernet Switch
  • Sixnet® SLX-5ES-3SC Unmanaged 5-port Industrial Ethernet Switch
  • Emerson Smart Wireless Gateway 1552WU
  • Emerson wireless control bridge
  • Emerson field data is wirelessly transmitted back
  • Emerson Wireless Remote Video Surveillance
  • Emerson DeltaV™ S series 4-port FF fieldbus I/O
  • Emerson DeltaV™ S series DeviceNet interface cards
  • Emerson DeltaV™ S series H1 I/O card with integrated power supply
  • Emerson DeltaV™ S series centralized connection solutions
  • Emerson DeltaV™ S series Profibus DP interface card
  • Emerson DeltaV™ S series serial interface
  • Emerson DeltaV™ S series SX controller
  • Emerson DeltaV™ Recipe Exchange
  • Emerson DeltaV™ Mobile
  • Emerson DeltaV™ M Series enhanced DC-to-DC power supply
  • Emerson DeltaV™ Virtual S Series and M Series controller simulation
  • Emerson DeltaV™ PK Flex controller
  • Emerson DeltaV Flex system
  • Emerson DeltaV™ M series Profibus DP Series 2 Plus interface card
  • Emerson DeltaV CTO DCS cabinet
  • Ntron Senz-TX oxygen sensor transmitter
  • ntron Compact SIL2 Capable Oxygen Analyzer – Ntron SIL-O2
  • Oxygen Analyzer – Ntron Microx
  • Medical Gas Analyzer – Ntron MoGas
  • Intrinsically Safe Compact Oxygen Transmitter – Minox-i
  • Ntron Microx-OL
  • Portable Oxygen and Moisture Analyzer – Ntron AM Trace
  • In-Line Process Oxygen Analyzer – Ntron OxyExtract
  • Ambient Oxygen Analyzer – Ntron Gasenz
  • Portable Oxygen Analyzer – Ntron Yellow Box
  • Industrial Oxygen Analyzers – GPR-1900 and GPR-2900
  • Oxygen Monitors – AII GPR-1500 GB/2500 GB
  • Thermo-Paramagnetic Oxygen Analyzer – Michell XTP501
  • Paramagnetic Oxygen Analyzer – Michell XPM601
  • N-Tron® NT24K-12GX4-SC-80 Industrial Ethernet Switch
  • N-Tron® NT24K-14FXE6-SC-80 Managed 14-Port Gigabit Industrial Ethernet Switch
  • N-Tron® 7012FXE2-SC-40 Managed 12-port Industrial Ethernet Switch
  • N-Tron® NT24K-11GX3-SC-PT Gigabit Industrial Ethernet Switch
  • N-Tron® NT24K-14FXE6-SC-15 Managed 14-Port Gigabit Industrial Ethernet Switch
  • N-Tron® 7018FXE2-SC-15 Managed 18-port Industrial Ethernet Switch
  • N-Tron® NT24k 24-Port Rackmount Gigabit Managed Industrial Ethernet Switch
  • N -Tron® 710FXE2-ST-80 Managed 10-port Industrial Ethernet Switch
  • N-Tron® NT24k 24-Port, Dual Redundant VDC Power Input
  • N -Tron® 712FXE4-SC-15-HV Industrial Ethernet Switch
  • N -Tron® 712FXE4-ST-15-HV Industrial Ethernet Switch
  • N-Tron® NT24K-10FX2-SC Industrial Ethernet Switch
  • N -Tron® 709FXE-SC-40 Managed 9-port Industrial Ethernet Switch
  • N-Tron® NT24K-12SFP-DM4 Gigabit Industrial Ethernet Switch
  • N-Tron® NT24k 16-Port, Single Redundant VDC Power Input
  • GE Multilin C30 Controller System
  • GE Multilin C650 Bay Control & Monitoring System
  • GE Reason MU320E
  • GE Reason MU360
  • GE MiCOM C264 Bay Controller
  • GE Multilin C60/C95 C60 Breaker Monitoring and Control
  • GE Multilin D.20 I/O Modules
  • GE Multilin D20E Advanced Substation I/O Modules
  • GE Multilin™ G500 Advanced Substation Gateway
  • GE Multilin™ G100 Advanced Substation Gateway
  • GE iSTAT i4Mx Standard multifunction transducer
  • iSTAT M365 Power Quality Metering with Extensive Logging and Communications
  • GE iSTAT M2x3 High Performance Measurement Centre
  • GE iSTAT M2x2 Standard Measurement Centre family
  • iSTAT i400 Mean Sensing Transducers and i4XS Communications Interface
  • GE iSTAT i500 High Performance Multifunction Transducer
  • GE MVTP Buswire Supervision Relay
  • GE MFAC High Impedance Bus Differential Relay
  • GE MCAG High Impedance Bus Differential Relay
  • GE P40 Agile P14N, P14D, P94V P40 Agile Feeder Management
  • GE MiCOM Agile P140 Series
  • GE MiCOM Agile P746 Centralized Busbar Differential Relay
  • GE MiCOM Agile P747 Centralized Busbar Differential Relay
  • GE Multilin B90 Low Impedance Bus Protection System
  • GE MiCOM Agile P74x Series
  • GE Multilin B30 Multiple Sections Low Impedance Busbar Protection
  • GE Dolin G60 generator protection system
  • ABBPCS 8000 AC Excitation AC Excitation for hydro pump energy storage plants
  • ABBCompact Product Suite Panel 800 Version 6 PP877 Hardware and Installation
  • ABBIndustrialIT Panel 800 - PP865 Version 5.1 Hardware and Installation
  • ABBSYSTEM DRIVES MEGADRIVE-LCI water-cooled User manual
  • ABBAdvant® Controller 450 The proven process controller
  • ABBAdvant® Master S100 I/O system
  • SYNCHROTACT® 5 Operating Instructions SYN 5201 SYN 5202
  • ABB EXCITATION SYSTEMS AND SYNCHRONIZING EQUIPMENT SYNCHROTACT® 5 Documentation Access
  • ABBAdvant® Master S100 I/O system
  • ABBCI853 Compact Product Suite hardware selector
  • ABBAC 800M and Communication interfaces Compact Product Suite Outline of all modules
  • ABBAC 800M Controller Hardware Product Guide
  • ABBAC 800M PROFIBUS DP Configuration
  • ABBCompact control system replaces PLCs Comfortable, more efficient integration of package units using AC 700F
  • ABBDistributed busbar protection REB500 including line and transformer protection Product Guide
  • ABB Procontic Progamming System 907 PC 331 Programming and Test Software
  • ABBDCS800 Quick guide DCS800 Drives (20 A to 5200 A)
  • ABBDCS Thyristor Power Converters for DC Drive Systems 25 to 5150 A Operating Instructions DCS 600 MultiDrive
  • ABBDrivetrain vibration damping with MEGADRIVE-LCI Improve reliability, extend lifetime and enhance performance
  • ABBMEGADRIVE-LCI water-cooled User manual
  • ABBDCS800 Hardware Manual DCS800 Drives (20 to 5200 A)
  • ABBDCS800 Quick guide DCS800 Drives (20 A to 5200 A)
  • ABBDCS Thyristor Power Converters for DC Drive Systems 25 to 5150 A Operating Instructions DCS 600 MultiDrive
  • ABBAdvant® OCS Open Control SystemAdvant Controller 110
  • ABBAdvant® OCS Open Control SystemAdvant Controller 210
  • ABBAdvant Fieldbus 100 User Manual
  • ABBAdvant® OCS Open Control SystemAdvant Controller 250
  • ABBAdvant Controller 160
  • ABBIndustrial Networks Connecting Controllers via OPC
  • ABBAdvant® OCSOpen Control SystemAdvant Controller 70
  • ABBAdvant Controller 31 40 & 50 Series
  • ABB Procontic CS 31 Intelligent decentralized automation system
  • ABBAdvant Controller 31 Intelligent Decentralized Automation System
  • ABBHardware Manual ACV 700 Frequency Converters
  • ABBGet more done better with Advant Controller 400 series
  • ABBElectro-Pneumatic Positioner TZIDC
  • ABBCase note ABB MNS iS The integrated solution for the WAGP project
  • ABBCondition MonitoringMService V7.7 - User Manua MService V7.7 - User Manua [Document Type] ABB Ability™ Condition Monitoring for electrical systems - CMES User Manual MService Condition Monitoring V7.7 User Manual
  • ABBMNS® Digital ABB Ability™ Condition Monitoring for electrical systems - CMES User Management – Quick guide ABB Ability™ Condition Monitoring for electrical systems – CMES User Management Quick Guide
  • ABB MEASUREMENT & ANALY TICS | DATA SHEET 266DSH Differential pressure transmitters
  • General Specifications FCN Autonomous Controller Hardware (FCN-500)
  • Unicom-JETNETJetNet 4510 Industrial 10-port Management Fast Ethernet Switch
  • TCC-80Port-powered RS-232 to RS-422/485 converter
  • Temaline Wiegand ModuleDigital Wiegand Multi I/O Management Device
  • ABBAC 800M Controller Hardware
  • MD00R-02/04 - Industrial PLC Workstation