DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
IS230TNEAH1A
❤ Add to collection

IS230TNEAH1A

IS230TNEAH1A
10055.00
¥4548.00
¥4548.00
¥4548.00
Weight:0.000KG
Description
IS230TNEAH1A

Part Number IS230TNEAH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS230TNEAH1A is an Emergency Trip DIN-Rail Module manufactured and designed by General Electric. It is a part of the Mark VIe Control System. The primary purpose of the component is to monitor and respond to critical events or abnormal conditions within the system. In the event of an emergency or a predefined trip condition, the module takes swift and decisive action to initiate an emergency shutdown, preventing any potential damage to equipment or personnel. The DIN-Rail form factor of the module makes it easy to mount within control cabinets or enclosures, providing a compact and space-saving solution for emergency trip functionality. This streamlined design allows for efficient integration into existing control systems, promoting ease of installation and maintenance. Installation The system incorporates multiple variants, each serving specific functions and features tailored to the diverse needs of industrial applications. These variants may include different configurations, software settings, or hardware options, allowing the system to adapt to a wide range of requirements. To ensure the system's safety and reliability, voltage detection and the breaker relay are skillfully wired to the I/O terminal blocks TB1. These terminal blocks act as essential connection points for input and output signals, efficiently interfacing with various components and devices within the system. By using TB1 for these critical connections, the system ensures accurate voltage monitoring and seamless operation of the breaker relay, contributing to enhanced safety and control over electrical circuits. 





Passive pulse rate pick-ups, on the other hand, are connected to TB2. This terminal block is specifically designated for accommodating the pick-ups, which are used for measuring and detecting pulse rates from various mechanical or electrical devices. By dedicating TB2 for these connections, the system ensures precise data acquisition and real-time monitoring of important parameters, enabling effective control and analysis. Both TB1 and TB2 terminal blocks are securely held in place with two screws each, providing a reliable and stable connection platform for the attached wires. The two-screw mounting mechanism ensures that the terminal blocks remain firmly in place even in dynamic and demanding industrial environments, preventing any accidental disconnections or disruptions. Each terminal block features 24 terminals, which are designed to accept wires up to #12 AWG in size. This versatility allows the system to accommodate a broad range of wire types and sizes, facilitating easy integration of various devices and sensors. The ability to handle #12 AWG wires ensures that the system can support higher current-carrying capacities, making it suitable for applications with higher power requirements. Additionally, a shield termination strip is thoughtfully positioned immediately to the left of each terminal block. This strip is attached to the chassis ground, providing a means to ground the shielded cables and wires connected to the terminal blocks. The presence of the shield termination strip enhances electromagnetic interference (EMI) protection and minimizes signal noise, ensuring accurate data transmission and reducing the risk of signal degradation. Contact outputs The contact outputs in the circuit exhibit polarity sensitivity, which means that the direction of current flow is critical for their proper operation. Therefore, it is crucial to wire the circuit with great care to prevent any potential damage to the relays. To avoid damaging the relays, meticulous attention must be given to the wiring process. Proper identification and orientation of the contact output terminals are essential. Ensuring that the correct polarity is maintained throughout the wiring is of utmost importance. Mistakes in connecting the wrong polarity can lead to unwanted consequences, such as overheating of the coils and contacts, premature wear and tear, and even complete failure of the relays. Moreover, the circuit lacks built-in contact or solenoid suppression, which means that the user must take additional measures to protect the relays and their contacts from voltage spikes and back-emf (electromotive force) generated during the switching process. When a relay coil is de-energized, it can produce a voltage spike that can cause arcing across the contacts. This arcing can lead to rapid wear of the contacts and eventually result in failure. To address this issue, external solenoid suppression must be added to the circuit. Solenoid suppression refers to the use of components, such as diodes or suppressor circuits, to protect the relay contacts from voltage spikes and back-emf. These components act as a pathway for the induced voltage, safely redirecting it away from the relay contacts. By implementing external solenoid suppression, the user can significantly enhance the reliability and lifespan of the relays and their contacts. This preventive measure ensures that any voltage spikes generated during the switching process are effectively absorbed and dissipated, preventing damage and minimizing arcing. Handling Precautions To prevent damage from static electricity, adhere to static-sensitive handling techniques when dealing with all boards. When handling boards or components, wear a wrist grounding strap, but only after boards or components have been removed from potentially energized equipment and are situated at a normally grounded workstation. Printed wiring boards may include static-sensitive components. Consequently, GE delivers all replacement boards in antistatic bags. Follow these guidelines when handling boards: Store boards in antistatic bags or boxes. Utilize a grounding strap when handling boards or board components (in accordance with prior caution criteria).EMER TRIP DIN RAIL MODULE

  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI
  • ABB Control product - Soft starter PST/PSTB (Intelligent Type)
  • ABB Automation System ABB Procontic T200
  • ABB PCS6000 medium voltage wind turbine converter
  • SYSTEM DRIVES PCS6000 ABB
  • ABB PP886 Compact Product Suite hardware selector
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Panel 800 Version 6- PP885
  • ABB IndustrialIT Panel 800 - PP846 Version 5.1
  • ABB IndustrialIT Panel 800 - PP836 Version 5.1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • ABB Advant® Master S100 I/O system
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • GE Reason RT431 GPS Precision-Time Clock
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany (2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • Advant™Automation with MOD 300™ Software
  • ABB MEASUREMENT & ANALYTICS EasyLine EL3000 / EL3060
  • ABB MEASUREMENT & ANALYTICS PGC5000 Process gas chromatograph
  • ABB AC servo motors BSM Series
  • ABB New BSD Series A complete range
  • ABB Advant Controller 110
  • ABB ASTAT® Crane motion controller Version AST10_054
  • ABB-Crane Control System - ASTAT
  • ABB Open Control System Advant Controller 210
  • ABB Open Control System Advant Controller 250
  • ABB Advant Controller 160
  • ABB DSCA33 High Performance Signal Conditioners
  • ABB Advant Controller 70 – Kompakter und leistungsfähiger
  • ABB Advant Controller 31 Hardware 90 Series