DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
IS220PGENH1A
❤ Add to collection

IS220PGENH1A

IS220PGENH1A
10055.00
¥4548.00
¥4548.00
¥4548.00
Weight:0.000KG
Description
IS220PGENH1A

Part Number IS220PGENH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockThe IS220PGENH1A is a Turbine Generator Monitor Module designed for the Mark VIe system. The electrical interface between one I/O Ethernet network and the TGNA turbine generator is provided by the Mark VIe Turbine-Generator Monitor (PGEN). The pack includes a processor board that is shared by all Mark VIe distributed I/O packs as well as an acquisition board. The pack monitors turbine mechanical power using three analog channels and voltage or 4-20 mA sensors. Functional Description A current transformer input is used to monitor each phase of the generator armature current. The PGEN performs the power load unbalances (PLU) function that the Mark VI VGEN did. It lacks the power calculations (kW, kVARS, KVA) and early valve actuation logic found in the VGEN. Dual RJ45 Ethernet connectors and a 3-pin power input provide power to the pack. For simplex or TMR applications, the PGEN supports single Ethernet networks. Output is via a DC-37 pin connector that is directly connected to the associated terminal board connector. LED indicator lights provide visual diagnostics. Compatibility PGENH1A functions with the turbine-generator Terminal Board (TGNA). The number of I/O packs used in a signal path is referred to as the control mode: Simplex employs a single I/O pack and a single network connection. TMR employs three I/O packs, each with one network connection. IS220PGENH1A Installation Securely mount the terminal board of choice. Insert one PGEN I/O pack for simplex or three PGEN I/O packs for TMR directly into the terminal board connectors. Use the threaded studs next to the Ethernet ports to mechanically secure the packs. The studs fit into a terminal board-specific mounting bracket. 






The bracket should be positioned so that no right angle force is applied to the DC-37 pin connector between the pack and the terminal board. The adjustment should only be needed once during the product's lifetime. Connect only one Ethernet cable. The pack can be used with either port. Connect the pack to power by plugging in the connector on the pack's side. Because the I/O pack has inherent soft-start capability that controls current inrush on power application, it is not necessary to disconnect power from the cable before plugging it in. Configure the I/O pack as needed using the ToolboxST application. Processor features Processor with high speed, RAM, and flash memory Two 10/100 Ethernet ports with connectors that are completely independent of one another Reset circuit and hardware watchdog timer Sensor for local ambient temperature LED status indicators Electronic identification and the ability to read IDs from other boards Significant programmable logic to support the acquisition board Soft start/current limiter input power connector Power supplies on-site, including sequencing and monitoring Auto-Reconfiguration The Auto-Reconfiguration feature allows the operator to replace I/O packs without having to manually reconfigure each pack or module. When the controller detects an I/O pack booting with a different configuration and the Auto-Reconfiguration feature is enabled, a reconfiguration file is automatically downloaded from the controller to the I/O pack. The bootload, baseload, firmware, and parameters are all reconfigured. Unless it already has the latest version, each I/O pack is updated with the current configuration that matches the configuration used by the controller. While an Auto-Reconfiguration is running, the controller will not allow a reboot until the Auto-Reconfiguration is complete. Other I/O pack downloads cannot be started while it is being Auto-Reconfigured. Auto-Reconfiguration only performs diagnostics if an I/O pack is already running. Turbine-Generator Monitoring Hardware An analog filter acquisition board is part of the PGEN application-specific hardware (BPAIH3). To improve analog-to-digital resolution, the analog filter acquisition board provides signal conditioning to center and amplify the signal. For three mechanical power sensors and three CT currents, the PGEN accepts analog input signals from the terminal board. An analog multiplexer block, several gain and scaling sections, and a 16-bit analog-to-digital converter comprise the analog input section (ADC). Depending on the input configuration, the three analog mechanical power inputs can be configured as 5 V, 10 V, or 4-20 mA scaled signals. The three current inputs are brought through 250 burden resistors on the terminal board if configured as 4-20 mA signals. At 20 mA, this resistance produces a 5 V signal. When configured for current inputs, the terminal board includes a 250 burden resistor that produces a 5 V signal at 20 mA. Power Load Unbalance Overspeed Control The Power Load Unbalance (PLU) function measures the difference between per unit steam turbine power and per unit generator power based on generator current. A PLU event occurs when the turbine per unit power is 40% greater than the generator power and the difference meets both the rate of change and the duration requirements. When a PLU event is detected, the steam turbine control and intercept valves (CVs) are closed to reduce power. The Iopack (PGEN) and the (TGNA) terminal board monitor the PLU. The PLU function can be used in either a TMR or a Simplex configuration. The steam turbine CV and IV valves are controlled by the Mark VIe Digital Output IOpack, PDOA, and TRLY (Simplex, H1F TMR) (TRLY) or terminal board. The PGEN controls the relay state on the PDOA. A peer-to-peer multicast packet that provides a fast communication path improves the control of the relays in the PDOA. The fast communication path runs alongside the normal pack-to-pack communication, which is routed through the signal space by the controller to transfer relay commands. The multicast path is only used to send commands to the relays. IS220PGENH1A Diagnostics The following self-diagnostic tests are performed by the pack: A power-on self-test that includes RAM, flash memory, Ethernet ports, and most processor board hardware checks. Constant monitoring of internal power supplies for proper operation A check of the terminal board, acquisition board, and processor board electronic ID information to confirm that the hardware set matches, followed by a check that the application code loaded from flash memory is correct for the hardware set. Hardware limit checking is performed on each analog or current input based on preset high and low levels near the end of the operating range. If this limit is exceeded, a logic signal in signal space is set to Unhealthy, and the unhealthy signal is forced to zero volts or mA. If the signal returns to its limits, the signal state returns to Healthy. If any of the signals is abnormal, the logic signal L3DIAG-PGEN is activated. System limit checking is performed on each input based on configurable high and low levels. These limits can be used to generate alarms, enable/disable devices, and as latching/non-latching switches. Precision reference voltages are included in each scan by the analog input hardware. The measured values are compared to the expected values to confirm the health of analog to digital circuits.IO PACK, GENERATOR PLU

  • Sixnet® SL-8ES-1 Unmanaged 8-port Industrial Ethernet Switch
  • ABB NE810 3BSE080207R1 Network switch
  • N-Tron® 1008TX Unmanaged 8-port Gigabit Industrial Ethernet Switch
  • N-Tron® 106FX2-SC-MDR Unmanaged 6-port Industrial Ethernet Switch
  • Sixnet® SLX-9ES-3SC Unmanaged 9-port Industrial Ethernet Switch
  • N-Tron® 106FXE2-SC-80-MDR Unmanaged 6-port Industrial Ethernet Switch
  • Sixnet® SLX-5ES-3SC Unmanaged 5-port Industrial Ethernet Switch
  • Emerson Smart Wireless Gateway 1552WU
  • Emerson wireless control bridge
  • Emerson field data is wirelessly transmitted back
  • Emerson Wireless Remote Video Surveillance
  • Emerson DeltaV™ S series 4-port FF fieldbus I/O
  • Emerson DeltaV™ S series DeviceNet interface cards
  • Emerson DeltaV™ S series H1 I/O card with integrated power supply
  • Emerson DeltaV™ S series centralized connection solutions
  • Emerson DeltaV™ S series Profibus DP interface card
  • Emerson DeltaV™ S series serial interface
  • Emerson DeltaV™ S series SX controller
  • Emerson DeltaV™ Recipe Exchange
  • Emerson DeltaV™ Mobile
  • Emerson DeltaV™ M Series enhanced DC-to-DC power supply
  • Emerson DeltaV™ Virtual S Series and M Series controller simulation
  • Emerson DeltaV™ PK Flex controller
  • Emerson DeltaV Flex system
  • Emerson DeltaV™ M series Profibus DP Series 2 Plus interface card
  • Emerson DeltaV CTO DCS cabinet
  • Ntron Senz-TX oxygen sensor transmitter
  • ntron Compact SIL2 Capable Oxygen Analyzer – Ntron SIL-O2
  • Oxygen Analyzer – Ntron Microx
  • Medical Gas Analyzer – Ntron MoGas
  • Intrinsically Safe Compact Oxygen Transmitter – Minox-i
  • Ntron Microx-OL
  • Portable Oxygen and Moisture Analyzer – Ntron AM Trace
  • In-Line Process Oxygen Analyzer – Ntron OxyExtract
  • Ambient Oxygen Analyzer – Ntron Gasenz
  • Portable Oxygen Analyzer – Ntron Yellow Box
  • Industrial Oxygen Analyzers – GPR-1900 and GPR-2900
  • Oxygen Monitors – AII GPR-1500 GB/2500 GB
  • Thermo-Paramagnetic Oxygen Analyzer – Michell XTP501
  • Paramagnetic Oxygen Analyzer – Michell XPM601
  • N-Tron® NT24K-12GX4-SC-80 Industrial Ethernet Switch
  • N-Tron® NT24K-14FXE6-SC-80 Managed 14-Port Gigabit Industrial Ethernet Switch
  • N-Tron® 7012FXE2-SC-40 Managed 12-port Industrial Ethernet Switch
  • N-Tron® NT24K-11GX3-SC-PT Gigabit Industrial Ethernet Switch
  • N-Tron® NT24K-14FXE6-SC-15 Managed 14-Port Gigabit Industrial Ethernet Switch
  • N-Tron® 7018FXE2-SC-15 Managed 18-port Industrial Ethernet Switch
  • N-Tron® NT24k 24-Port Rackmount Gigabit Managed Industrial Ethernet Switch
  • N -Tron® 710FXE2-ST-80 Managed 10-port Industrial Ethernet Switch
  • N-Tron® NT24k 24-Port, Dual Redundant VDC Power Input
  • N -Tron® 712FXE4-SC-15-HV Industrial Ethernet Switch
  • N -Tron® 712FXE4-ST-15-HV Industrial Ethernet Switch
  • N-Tron® NT24K-10FX2-SC Industrial Ethernet Switch
  • N -Tron® 709FXE-SC-40 Managed 9-port Industrial Ethernet Switch
  • N-Tron® NT24K-12SFP-DM4 Gigabit Industrial Ethernet Switch
  • N-Tron® NT24k 16-Port, Single Redundant VDC Power Input
  • GE Multilin C30 Controller System
  • GE Multilin C650 Bay Control & Monitoring System
  • GE Reason MU320E
  • GE Reason MU360
  • GE MiCOM C264 Bay Controller
  • GE Multilin C60/C95 C60 Breaker Monitoring and Control
  • GE Multilin D.20 I/O Modules
  • GE Multilin D20E Advanced Substation I/O Modules
  • GE Multilin™ G500 Advanced Substation Gateway
  • GE Multilin™ G100 Advanced Substation Gateway
  • GE iSTAT i4Mx Standard multifunction transducer
  • iSTAT M365 Power Quality Metering with Extensive Logging and Communications
  • GE iSTAT M2x3 High Performance Measurement Centre
  • GE iSTAT M2x2 Standard Measurement Centre family
  • iSTAT i400 Mean Sensing Transducers and i4XS Communications Interface
  • GE iSTAT i500 High Performance Multifunction Transducer
  • GE MVTP Buswire Supervision Relay
  • GE MFAC High Impedance Bus Differential Relay
  • GE MCAG High Impedance Bus Differential Relay
  • GE P40 Agile P14N, P14D, P94V P40 Agile Feeder Management
  • GE MiCOM Agile P140 Series
  • GE MiCOM Agile P746 Centralized Busbar Differential Relay
  • GE MiCOM Agile P747 Centralized Busbar Differential Relay
  • GE Multilin B90 Low Impedance Bus Protection System
  • GE MiCOM Agile P74x Series
  • GE Multilin B30 Multiple Sections Low Impedance Busbar Protection
  • GE Dolin G60 generator protection system
  • ABBPCS 8000 AC Excitation AC Excitation for hydro pump energy storage plants
  • ABBCompact Product Suite Panel 800 Version 6 PP877 Hardware and Installation
  • ABBIndustrialIT Panel 800 - PP865 Version 5.1 Hardware and Installation
  • ABBSYSTEM DRIVES MEGADRIVE-LCI water-cooled User manual
  • ABBAdvant® Controller 450 The proven process controller
  • ABBAdvant® Master S100 I/O system
  • SYNCHROTACT® 5 Operating Instructions SYN 5201 SYN 5202
  • ABB EXCITATION SYSTEMS AND SYNCHRONIZING EQUIPMENT SYNCHROTACT® 5 Documentation Access
  • ABBAdvant® Master S100 I/O system
  • ABBCI853 Compact Product Suite hardware selector
  • ABBAC 800M and Communication interfaces Compact Product Suite Outline of all modules
  • ABBAC 800M Controller Hardware Product Guide
  • ABBAC 800M PROFIBUS DP Configuration
  • ABBCompact control system replaces PLCs Comfortable, more efficient integration of package units using AC 700F
  • ABBDistributed busbar protection REB500 including line and transformer protection Product Guide
  • ABB Procontic Progamming System 907 PC 331 Programming and Test Software
  • ABBDCS800 Quick guide DCS800 Drives (20 A to 5200 A)
  • ABBDCS Thyristor Power Converters for DC Drive Systems 25 to 5150 A Operating Instructions DCS 600 MultiDrive
  • ABBDrivetrain vibration damping with MEGADRIVE-LCI Improve reliability, extend lifetime and enhance performance
  • ABBMEGADRIVE-LCI water-cooled User manual
  • ABBDCS800 Hardware Manual DCS800 Drives (20 to 5200 A)
  • ABBDCS800 Quick guide DCS800 Drives (20 A to 5200 A)
  • ABBDCS Thyristor Power Converters for DC Drive Systems 25 to 5150 A Operating Instructions DCS 600 MultiDrive
  • ABBAdvant® OCS Open Control SystemAdvant Controller 110
  • ABBAdvant® OCS Open Control SystemAdvant Controller 210
  • ABBAdvant Fieldbus 100 User Manual
  • ABBAdvant® OCS Open Control SystemAdvant Controller 250
  • ABBAdvant Controller 160
  • ABBIndustrial Networks Connecting Controllers via OPC
  • ABBAdvant® OCSOpen Control SystemAdvant Controller 70
  • ABBAdvant Controller 31 40 & 50 Series
  • ABB Procontic CS 31 Intelligent decentralized automation system
  • ABBAdvant Controller 31 Intelligent Decentralized Automation System
  • ABBHardware Manual ACV 700 Frequency Converters
  • ABBGet more done better with Advant Controller 400 series
  • ABBElectro-Pneumatic Positioner TZIDC
  • ABBCase note ABB MNS iS The integrated solution for the WAGP project
  • ABBCondition MonitoringMService V7.7 - User Manua MService V7.7 - User Manua [Document Type] ABB Ability™ Condition Monitoring for electrical systems - CMES User Manual MService Condition Monitoring V7.7 User Manual
  • ABBMNS® Digital ABB Ability™ Condition Monitoring for electrical systems - CMES User Management – Quick guide ABB Ability™ Condition Monitoring for electrical systems – CMES User Management Quick Guide
  • ABB MEASUREMENT & ANALY TICS | DATA SHEET 266DSH Differential pressure transmitters
  • General Specifications FCN Autonomous Controller Hardware (FCN-500)
  • Unicom-JETNETJetNet 4510 Industrial 10-port Management Fast Ethernet Switch
  • TCC-80Port-powered RS-232 to RS-422/485 converter
  • Temaline Wiegand ModuleDigital Wiegand Multi I/O Management Device
  • ABBAC 800M Controller Hardware
  • MD00R-02/04 - Industrial PLC Workstation